Automated development of the contrast-detail curve based on statistical low-contrast detectability in CT images.
image quality
low-contrast detectability
minimum detectable contrast
Journal
Journal of applied clinical medical physics
ISSN: 1526-9914
Titre abrégé: J Appl Clin Med Phys
Pays: United States
ID NLM: 101089176
Informations de publication
Date de publication:
Sep 2022
Sep 2022
Historique:
revised:
21
06
2022
received:
18
02
2022
accepted:
22
06
2022
pubmed:
10
7
2022
medline:
28
9
2022
entrez:
9
7
2022
Statut:
ppublish
Résumé
We have developed a software to automatically find the contrast-detail (C-D) curve based on the statistical low-contrast detectability (LCD) in images of computed tomography (CT) phantoms at multiple cell sizes and to generate minimum detectable contrast (MDC) characteristics. A simple graphical user interface was developed to set the initial parameters needed to create multiple grid region of interest of various cell sizes with a 2-pixel increment. For each cell in the grid, the average CT number was calculated to obtain the standard deviation (SD). Detectability was then calculated by multiplying the SD of the mean CT numbers by 3.29. This process was automatically repeated as many times as the cell size was set at initialization. Based on the obtained LCD, the C-D curve was obtained and the target size at an MDC of 0.6% (i.e., 6-HU difference) was determined. We subsequently investigated the consistency of the target sizes for a 0.6% MDC at four locations within the homogeneous image. We applied the software to images with six noise levels, images of two modules of the American College of Radiology CT phantom, images of four different phantoms, and images of four different CT scanners. We compared the target sizes at a 0.6% MDC based on the statistical LCD and the results from a human observer. The developed system was able to measure C-D curves from different phantoms and scanners. We found that the C-D curves follow a power-law fit. We found that higher noise levels resulted in a higher MDC for a target of the same size. The low-contrast module image had a slightly higher MDC than the distance module image. The minimum size of an object detected by visual observation was slightly larger than the size using statistical LCD. The statistical LCD measurement method can generate a C-D curve automatically, quickly, and objectively.
Identifiants
pubmed: 35808971
doi: 10.1002/acm2.13719
pmc: PMC9512356
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
e13719Informations de copyright
© 2022 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, LLC on behalf of The American Association of Physicists in Medicine.
Références
Oral Surg Oral Med Oral Pathol Oral Radiol. 2014 Nov;118(5):603-11
pubmed: 25442498
Biomed Res Int. 2014;2014:231090
pubmed: 24812609
J Appl Clin Med Phys. 2017 Mar;18(2):163-169
pubmed: 28300384
Radiology. 2015 Aug;276(2):499-506
pubmed: 25811326
J Biomed Phys Eng. 2020 Oct 01;10(5):623-634
pubmed: 33134222
J Appl Clin Med Phys. 2022 Sep;23(9):e13719
pubmed: 35808971
J Appl Clin Med Phys. 2020 Feb;21(2):128-135
pubmed: 31898865
Eur Radiol Exp. 2017;1(1):18
pubmed: 29708194
Eur Radiol. 2017 Mar;27(3):927-937
pubmed: 27300195
J Appl Clin Med Phys. 2021 Jul;22(7):313-321
pubmed: 34109738
Phys Med Biol. 2015 Oct 7;60(19):7671-94
pubmed: 26389637
Radiology. 2013 Nov;269(2):511-8
pubmed: 23788715
Radiology. 2015 Jun;275(3):735-45
pubmed: 25751228
Med Sci (Basel). 2020 Jul 06;8(3):
pubmed: 32640553
Med Phys. 2014 Jan;41(1):011908
pubmed: 24387516
Med Phys. 2009 Nov;36(11):4911-9
pubmed: 19994500
Radiology. 2004 Mar;230(3):619-28
pubmed: 14739312
J Thorac Imaging. 2004 Jan;19(1):16-23
pubmed: 14712126
J Radiol Prot. 2019 Sep;39(3):783-793
pubmed: 31117064
Med Phys. 2017 Mar;44(3):1168-1185
pubmed: 28303644
Radiology. 2005 Dec;237(3):905-10
pubmed: 16237139
Med Phys. 2011 Jul;38 Suppl 1:S25
pubmed: 21978115
Clin Radiol. 2015 Apr;70(4):366-72
pubmed: 25554541
Med Phys. 2017 Aug;44(8):3990-3999
pubmed: 28555878
Med Phys. 2004 Sep;31(9):2423-42
pubmed: 15487722
Phys Med. 2014 Jun;30(4):521-6
pubmed: 24530005
Radiology. 2016 Aug;280(2):475-82
pubmed: 26937709
J Xray Sci Technol. 2007;15(1):9-18
pubmed: 17710119
West J Emerg Med. 2012 May;13(2):202-10
pubmed: 22900113