Résumé

Interventional endoscopic ultrasonography is performed for various situations that require drainage, after which stent migration is the most severe adverse event. Several lumen-apposing metal stents (LAMS) and covered self-expandable metal stents (CSEMS) provide antimigration systems; however, their anchoring ability has not been studied well. Therefore, we measured and compared the anchoring force (ACF) of commercially available LAMS and CSEMS. Anchoring force was measured for five types of LAMS (NAGI, SPAXUS, Plumber, and AXIOS 8 and 10 mm) and seven types of CSEMS (BCL, SHCL, BCG, BPD [four types of HANAROSTENT], HILZO, Niti-S [Spring Stopper], and Wallflex). We created a phantom model for inducing stent migration. It has a rotatable part as a curved fixture, and we measured ACF at angles between 0° and 40°. The mean ACF at 0° and 20° were NAGI 1.50, 1.84 N, SPAXUS 1.73, 1.72 N, Plumber 2.64, 2.03 N, and AXIOS 3.96, 3.61 N, respectively; and BCL 0.48, 0.53 N, Wallflex 0.53, 0.48 N, SHCL 0.64, 0.73 N, HILZO 1.09, 1.09 N, BCG 1.22, 1.20 N, BPD 1.78, 1.67 N, and Spring Stopper 2.29, 2.51 N. We measured ACF in LAMS and CSEMS with a new phantom model. The highest value among the LAMS was for the AXIOS and among the CSEMS was for the Spring Stopper. Some of the ACF values varied with the direction of pull. These findings may have a significant impact on stent selection for interventional endoscopic ultrasonography, and this model can be used to evaluate newly developed stents.

Identifiants

pubmed: 35837746
doi: 10.1111/den.14406
doi:

Substances chimiques

BCG Vaccine 0

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

96-102

Informations de copyright

© 2022 Japan Gastroenterological Endoscopy Society.

Références

Isayama H, Nakai Y, Itoi T et al. Clinical practice guidelines for safe performance of endoscopic ultrasound/ultrasonography-guided biliary drainage: 2018. J Hepatobiliary Pancreat Sci 2019; 26: 249-69.
On W, Paranandi B, Smith AM et al. EUS-guided choledochoduodenostomy with electrocautery-enhanced lumen-apposing metal stents in patients with malignant distal biliary obstruction: Multicenter collaboration from the United Kingdom and Ireland. Gastrointest Endosc 2022; 95: 432-42.
Irani S, Jalaj S, Ross A, Larsen M, Grimm IS, Baron TH. Use of a lumen-apposing metal stent to treat GI strictures (with videos). Gastrointest Endosc 2017; 85: 1285-9.
Martins FP, Rossini LG, Ferrari AP. Migration of a covered metallic stent following endoscopic ultrasound-guided hepaticogastrostomy: Fatal complication. Endoscopy 2010; 42 (Suppl 2): E126-7.
Okuno N, Hara K, Mizuno N, Hijioka S, Imaoka H, Yamao K. Stent migration into the peritoneal cavity following endoscopic ultrasound-guided hepaticogastrostomy. Endoscopy 2015; 47 (Suppl 1 UCTN): E311.
Sanchez-Ocana R, Penas-Herrero I, Santos-Santamarta F, de la Serna-Higuera C, Perez-Miranda M. EUS-guided removal of a buried lumen-apposing metal stent caused by delayed inward migration after cyst-gastrostomy. Gastrointest Endosc 2017; 86: 229.
Ochiai K, Fujisawa T, Ishii S et al. Risk factors for stent migration into the abdominal cavity after endoscopic ultrasound-guided hepaticogastrostomy. J Clin Med 2021; 10: 3111.
Nakai Y, Isayama H, Yamamoto N et al. Safety and effectiveness of a long, partially covered metal stent for endoscopic ultrasound-guided hepaticogastrostomy in patients with malignant biliary obstruction. Endoscopy 2016; 48: 1125-8.
Nakai Y, Sato T, Hakuta R et al. Long-term outcomes of a long, partially covered metal stent for EUS-guided hepaticogastrostomy in patients with malignant biliary obstruction (with video). Gastrointest Endosc 2020; 92: 623-31.
Miyano A, Ogura T, Yamamoto K, Okuda A, Nishioka N, Higuchi K. Clinical impact of the intra-scope channel stent release technique in preventing stent migration during EUS-guided hepaticogastrostomy. J Gastrointest Surg 2018; 22: 1312-8.
Fujisawa T, Isayama H, Ishii S. “ClipFlap” anchoring method for endoscopic ultrasonography-guided hepaticogastrostomy with a covered self-expandable metallic stent. Dig Endosc 2020; 32: 628.
Shima Y, Isayama H, Ito Y et al. Crisscross anchor-stents to prevent metal stent migration during endoscopic ultrasound-guided hepaticogastrostomy. Endoscopy 2014; 46 (Suppl 1 UCTN): E563.
Ogura T, Kitano M, Okuda A et al. Endoscopic ultrasonography-guided hepaticogastrostomy using a novel laser-cut type partially covered self-expandable metal stent (with video). Dig Endosc 2021; 33: 1188-93.
Kiyanagi A, Fujisawa T, Ishii S et al. Usefulness of routine plain CT the day after an interventional EUS procedure. Saudi J Gastroenterol 2021; 27: 275-82.
Teoh AY, Ng EK, Chan SM et al. Ex vivo comparison of the lumen-apposing properties of EUS-specific stents (with video). Gastrointest Endosc 2016; 84: 62-8.
Tonozuka R, Yunoki S, Itoi T et al. Ex vivo assessment of anchoring force of covered biflanged metal stent and covered self-expandable metal stent for interventional endoscopic ultrasound. J Gastroenterol Hepatol 2019; 34: 194-201.
Minaga K, Kitano M, Imai H et al. Evaluation of anti-migration properties of biliary covered self-expandable metal stents. World J Gastroenterol 2016; 22: 6917-24.
Mangiavillano B, Moon JH, Crino SF et al. Safety and efficacy of a novel electrocautery-enhanced lumen-apposing metal stent in interventional EUS procedures (with video). Gastrointest Endosc 2021; 95: 115-22.
Petrone MC, Archibugi L, Forti E et al. Novel lumen-apposing metal stent for the drainage of pancreatic fluid collections: An Italian multicentre experience. United European Gastroenterol J 2018; 6: 1363-71.
Paik WH, Park DH, Choi JH et al. Simplified fistula dilation technique and modified stent deployment maneuver for EUS-guided hepaticogastrostomy. World J Gastroenterol 2014; 20: 5051-9.

Auteurs

Yusuke Takasaki (Y)

Department of Gastroenterology, Graduate School of Medicine, Juntendo University, Tokyo, Japan.

Hiroyuki Isayama (H)

Department of Gastroenterology, Graduate School of Medicine, Juntendo University, Tokyo, Japan.

Kyoung Sub Shin (KS)

M.I.Tech Co., Ltd, Pyeongtaek, South Korea.

Shigeto Ishii (S)

Department of Gastroenterology, Graduate School of Medicine, Juntendo University, Tokyo, Japan.

Toshio Fujisawa (T)

Department of Gastroenterology, Graduate School of Medicine, Juntendo University, Tokyo, Japan.

Jong Pil Moon (JP)

M.I.Tech Co., Ltd, Pyeongtaek, South Korea.

Taito Fukuma (T)

Department of Gastroenterology, Graduate School of Medicine, Juntendo University, Tokyo, Japan.

Mako Ushio (M)

Department of Gastroenterology, Graduate School of Medicine, Juntendo University, Tokyo, Japan.

Sho Takahashi (S)

Department of Gastroenterology, Graduate School of Medicine, Juntendo University, Tokyo, Japan.

Akinori Suzuki (A)

Department of Gastroenterology, Graduate School of Medicine, Juntendo University, Tokyo, Japan.

Koichi Ito (K)

Department of Gastroenterology, Graduate School of Medicine, Juntendo University, Tokyo, Japan.

Ko Tomishima (K)

Department of Gastroenterology, Graduate School of Medicine, Juntendo University, Tokyo, Japan.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH