MRI compatibility of orthodontic brackets and wires: systematic review article.

Fixed orthodontics appliances Magnetic resonance imaging Orthodontic bracket Orthodontic retainers Orthodontic wire Orthodontics

Journal

BMC oral health
ISSN: 1472-6831
Titre abrégé: BMC Oral Health
Pays: England
ID NLM: 101088684

Informations de publication

Date de publication:
19 07 2022
Historique:
received: 02 04 2022
accepted: 05 07 2022
entrez: 19 7 2022
pubmed: 20 7 2022
medline: 22 7 2022
Statut: epublish

Résumé

Before the magnetic resonance imaging (MRI) examination fixed orthodontic devices, such as brackets and wires, cause challenges not only for the orthodontist but also for the radiologist. Essentially, the MRI-safe scan of the fixed orthodontic tools requires a proper guideline in clinical practice. Therefore, this systematic review aimed to examine all aspects of MRI-safe scan, including artifact, thermal, and debonding effects, to identify any existing gaps in knowledge in this regard and develop an evidence-based protocol. The Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) statement was used in this study. The clinical question in "PIO" format was: "Does MRI examination influence the temperature of the orthodontic devices, the size of artifacts, and the debonding force in patients who have fixed orthodontic bracket and/or wire?" The search process was carried out in PubMed, PubMed Central, Scopus, and Google Scholar databases. The search resulted in 1310 articles. After selection according to the eligibility criteria, 18 studies were analyzed by two reviewers. The risk of bias was determined using the Quality In Prognosis Studies tool. Out of the eligible 18 studies, 10 articles examined the heating effect, 6 were about the debonding effect, and 11 measured the size of artifact regarding brackets and wires. Considering the quality assessment, the overall levels of evidence were high and medium. The published studies showed that heating and debonding effects during MRI exposure were not hazardous for patients. As some wires revealed higher temperature changes, it is suggested to remove the wire or insert a spacer between the appliances and the oral mucosa. Based on the material, ceramic and plastic brackets caused no relevant artifact and were MRI-safe. Stainless steel brackets and wires resulted in susceptibility artifacts in the orofacial region and could cause distortion in the frontal lobe, orbits, and pituitary gland. The retainer wires showed no relevant artifact. In conclusion, the thermal and debonding effects of the fixed orthodontic brackets and wires were irrelevant or resoluble; however, the size of the artifacts was clinically relevant and determined most significantly the feasibility of fixed brackets and wires in MRI examination.

Sections du résumé

BACKGROUND
Before the magnetic resonance imaging (MRI) examination fixed orthodontic devices, such as brackets and wires, cause challenges not only for the orthodontist but also for the radiologist. Essentially, the MRI-safe scan of the fixed orthodontic tools requires a proper guideline in clinical practice. Therefore, this systematic review aimed to examine all aspects of MRI-safe scan, including artifact, thermal, and debonding effects, to identify any existing gaps in knowledge in this regard and develop an evidence-based protocol.
METHODS
The Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) statement was used in this study. The clinical question in "PIO" format was: "Does MRI examination influence the temperature of the orthodontic devices, the size of artifacts, and the debonding force in patients who have fixed orthodontic bracket and/or wire?" The search process was carried out in PubMed, PubMed Central, Scopus, and Google Scholar databases. The search resulted in 1310 articles. After selection according to the eligibility criteria, 18 studies were analyzed by two reviewers. The risk of bias was determined using the Quality In Prognosis Studies tool.
RESULTS
Out of the eligible 18 studies, 10 articles examined the heating effect, 6 were about the debonding effect, and 11 measured the size of artifact regarding brackets and wires. Considering the quality assessment, the overall levels of evidence were high and medium. The published studies showed that heating and debonding effects during MRI exposure were not hazardous for patients. As some wires revealed higher temperature changes, it is suggested to remove the wire or insert a spacer between the appliances and the oral mucosa. Based on the material, ceramic and plastic brackets caused no relevant artifact and were MRI-safe. Stainless steel brackets and wires resulted in susceptibility artifacts in the orofacial region and could cause distortion in the frontal lobe, orbits, and pituitary gland. The retainer wires showed no relevant artifact.
CONCLUSIONS
In conclusion, the thermal and debonding effects of the fixed orthodontic brackets and wires were irrelevant or resoluble; however, the size of the artifacts was clinically relevant and determined most significantly the feasibility of fixed brackets and wires in MRI examination.

Identifiants

pubmed: 35854295
doi: 10.1186/s12903-022-02317-9
pii: 10.1186/s12903-022-02317-9
pmc: PMC9295293
doi:

Substances chimiques

Stainless Steel 12597-68-1

Types de publication

Journal Article Systematic Review Research Support, Non-U.S. Gov't

Langues

eng

Sous-ensembles de citation

IM

Pagination

298

Informations de copyright

© 2022. The Author(s).

Références

J Orofac Orthop. 2006 Nov;67(6):424-9
pubmed: 17124561
AJNR Am J Neuroradiol. 1987 Sep-Oct;8(5):837-40
pubmed: 3118677
Dentomaxillofac Radiol. 2017 Aug;46(6):20170051
pubmed: 28452576
Int Orthod. 2019 Sep;17(3):403-414
pubmed: 31285157
Radiology. 1988 Mar;166(3):777-9
pubmed: 3340777
Imaging Sci Dent. 2021 Mar;51(1):63-71
pubmed: 33828963
Radiology. 1983 Apr;147(1):139-48
pubmed: 6828719
Am J Orthod Dentofacial Orthop. 2004 Dec;126(6):717-24
pubmed: 15592221
Br Dent J. 2018 Oct 26;225(8):684
pubmed: 30361574
Dentomaxillofac Radiol. 2015;44(6):20140416
pubmed: 25734243
J Oral Biol Craniofac Res. 2016 May-Aug;6(2):142-52
pubmed: 27195213
Clin Oral Investig. 2017 Jan;21(1):281-289
pubmed: 26984824
PLoS One. 2012;7(2):e31766
pubmed: 22384071
PLoS Med. 2009 Jul 21;6(7):e1000097
pubmed: 19621072
J Magn Reson Imaging. 2006 Oct;24(4):735-46
pubmed: 16958057
Front Neurol. 2017 May 30;8:232
pubmed: 28611728
J Orofac Orthop. 2005 Jul;66(4):279-87
pubmed: 16044226
Am J Orthod Dentofacial Orthop. 2008 Oct;134(4):563-72
pubmed: 18929275
Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2003 Feb;95(2):255-63
pubmed: 12582369
Magn Reson Med. 2014 Oct;72(4):1191-8
pubmed: 24408149
Dentomaxillofac Radiol. 2014;43(2):20130356
pubmed: 24257741
J Pharm Bioallied Sci. 2013 Jun;5(Suppl 1):S113-6
pubmed: 23946562
BMJ. 2011 Oct 18;343:d5928
pubmed: 22008217
Orthod Fr. 2017 Jun;88(2):131-138
pubmed: 28597834
Health Aff (Millwood). 2008 Nov-Dec;27(6):1491-502
pubmed: 18997204
Ann Intern Med. 2013 Feb 19;158(4):280-6
pubmed: 23420236
Dentomaxillofac Radiol. 2013;42(5):20120234
pubmed: 23520391
Eur J Orthod. 2015 Dec;37(6):610-7
pubmed: 25667040
Restor Dent Endod. 2018 Aug 30;43(4):e39
pubmed: 30483463
Materials (Basel). 2019 Nov 30;12(23):
pubmed: 31801202
Med Oral Patol Oral Cir Bucal. 2009 Jun 01;14(6):E278-82
pubmed: 19300375

Auteurs

Adrienn Dobai (A)

Department of Oral Diagnostics, Faculty of Dentistry, Semmelweis University, Szentkirályi u. 47, Budapest, 1088, Hungary. adrienn.dobai@gmail.com.

Fanni Dembrovszky (F)

Institute for Translational Medicine, Medical School, University of Pécs, Szigeti Street 12, Pecs, 7024, Hungary.

Tamás Vízkelety (T)

Dento-Cura Private Practice, Kálvin Street 3, Budapest, 1053, Hungary.

Péter Barsi (P)

Department of Neuroradiology, Medical Imaging Centre, Semmelweis University, Balassa Street 6, Budapest, 1083, Hungary.

Fanni Juhász (F)

Department of Paediatric Dentistry and Orthodontics, Faculty of Dentistry, Semmelweis University, Szentkirályi u. 47, Budapest, 1088, Hungary.

Csaba Dobó-Nagy (C)

Department of Oral Diagnostics, Faculty of Dentistry, Semmelweis University, Szentkirályi u. 47, Budapest, 1088, Hungary.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH