Lower refractive prediction accuracy of total keratometry using intraocular lens formulas loaded onto a swept-source optical biometer.


Journal

Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie
ISSN: 1435-702X
Titre abrégé: Graefes Arch Clin Exp Ophthalmol
Pays: Germany
ID NLM: 8205248

Informations de publication

Date de publication:
Jan 2023
Historique:
received: 26 03 2022
accepted: 19 07 2022
revised: 08 07 2022
pubmed: 27 7 2022
medline: 4 1 2023
entrez: 26 7 2022
Statut: ppublish

Résumé

To compare refractive outcomes calculated using intraocular lens (IOL) power calculation formulas loaded onto the IOLMaster 700 with the employment of anterior keratometry (K) and total keratometry (TK). A total of 225 eyes of 225 patients underwent uneventful cataract surgery and implantation of a single model of nontoric monofocal IOL by a single surgeon. All eyes underwent preoperative ocular biometric measurements with the IOLMaster 700. Refractive outcomes, including the mean numerical prediction error (MNE); standard deviation (SD); adjusted mean absolute prediction error (MAE); adjusted median absolute prediction error (MedAE); percentages of eyes with adjusted prediction error (PE) within ± 0.25, ± 0.50, ± 0.75, and ± 1.00 diopter; and IOL Formula Performance Index (FPI), were compared between the K-based formula and the TK-based formula of Barrett Universal II (BUII), Haigis, SRK/T, Holladay 2, and Hoffer Q. Axial length (short, medium, and long) subgroup analyses and anterior and posterior keratometry (flat, medium, and steep) subgroup analyses were conducted. The K-based formula performed better than the TK-based formula in the accuracy of refractive prediction of each IOL calculation formula: BUII-K (FPI 0.690), BUII-TK (0.677), Haigis-K (0.617), Haigis-TK (0.584), SRK/T-K (0.608), SRK/T-TK (0.595), Holladay 2-K (0.419), Holladay 2-TK (0.406), Hoffer Q-K (0.364), and Hoffer Q-TK (0.356). The subgroup analyses of refractive prediction outcomes showed that TK influenced the refractive outcomes in eyes with relatively normal ranges of axial length and anterior keratometry. Using TK instead of K leads to lower refractive prediction accuracy of the IOL power calculation formulas loaded on the IOLMaster 700.

Identifiants

pubmed: 35881200
doi: 10.1007/s00417-022-05777-5
pii: 10.1007/s00417-022-05777-5
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

137-146

Informations de copyright

© 2022. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.

Références

Olsen T (2007) Calculation of intraocular lens power: a review. Acta Ophthalmol Scand 85:472–485. https://doi.org/10.1111/j.1600-0420.2007.00879.x
doi: 10.1111/j.1600-0420.2007.00879.x
Koch DD, Hill W, Abulafia A, Wang L (2017) Pursuing perfection in intraocular lens calculations: I. Logical approach for classifying IOL calculation formulas. J Cataract Refract Surg 43:717–718. https://doi.org/10.1016/j.jcrs.2017.06.006
doi: 10.1016/j.jcrs.2017.06.006
Retzlaff JA, Sanders DR, Kraff MC (1990) Development of the SRK/T intraocular lens implant power calculation formula. J Cataract Refract Surg 16:333–340. https://doi.org/10.1016/s0886-3350(13)80705-5 (Erratum.In:JCataractRefractSurg(1990)16:528)
doi: 10.1016/s0886-3350(13)80705-5
Hoffer KJ (1993) The Hoffer Q formula: a comparison of theoretic and regression formulas. J Cataract Refract Surg 19:700–712. https://doi.org/10.1016/s0886-3350(13)80338-0 (errata, (1994) 20(677), pp. 33, 2007.2-3)
doi: 10.1016/s0886-3350(13)80338-0
Haigis W, Lege B, Miller N, Schneider B (2000) Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis. Graefes Arch Clin Exp Ophthalmol 238:765–773. https://doi.org/10.1007/s004170000188
doi: 10.1007/s004170000188
Cooke DL, Cooke TL (2016) Comparison of 9 intraocular lens power calculation formulas. J Cataract Refract Surg 42:1157–1164. https://doi.org/10.1016/j.jcrs.2016.06.029
doi: 10.1016/j.jcrs.2016.06.029
Kane JX, Van Heerden A, Atik A, Petsoglou C (2016) Intraocular lens power formula accuracy: comparison of 7 formulas. J Cataract Refract Surg 42:1490–1500. https://doi.org/10.1016/j.jcrs.2016.07.021
doi: 10.1016/j.jcrs.2016.07.021
Kane JX, Van Heerden A, Atik A, Petsoglou C (2017) Accuracy of 3 new methods for intraocular lens power selection. J Cataract Refract Surg 43:333–339. https://doi.org/10.1016/j.jcrs.2016.12.021
doi: 10.1016/j.jcrs.2016.12.021
Melles RB, Holladay JT, Chang WJ (2018) Accuracy of intraocular lens calculation formulas. Ophthalmology 125:169–178. https://doi.org/10.1016/j.ophtha.2017.08.027
doi: 10.1016/j.ophtha.2017.08.027
Srivannaboon S, Chirapapaisan C, Chonpimai P, Loket S (2015) Clinical comparison of a new swept-source optical coherence tomography-based optical biometer and a time-domain optical coherence tomography-based optical biometer. J Cataract Refract Surg 41:2224–2232. https://doi.org/10.1016/j.jcrs.2015.03.019
doi: 10.1016/j.jcrs.2015.03.019
Montés-Micó R, Pastor-Pascual F, Ruiz-Mesa R, Tañá-Rivero P (2021) Ocular biometry with swept-source optical coherence tomography. J Cataract Refract Surg 47:802–814. https://doi.org/10.1097/j.jcrs.0000000000000551
doi: 10.1097/j.jcrs.0000000000000551
LaHood BR, Goggin M (2018) Measurement of posterior corneal astigmatism by the IOLMaster 700. J Refract Surg 34:331–336. https://doi.org/10.3928/1081597X-20180214-02
doi: 10.3928/1081597X-20180214-02
Savini G, Næser K (2015) An analysis of the factors influencing the residual refractive astigmatism after cataract surgery with toric intraocular lenses. Invest Ophthalmol Vis Sci 56:827–835. https://doi.org/10.1167/iovs.14-15903
doi: 10.1167/iovs.14-15903
Klijn S, Reus NJ, van der Sommen CM, Sicam VA (2016) Accuracy of total corneal astigmatism measurements with a Scheimpflug imager and a color light-emitting diode corneal topographer. Am J Ophthalmol 167:72–78. https://doi.org/10.1016/j.ajo.2016.04.011
doi: 10.1016/j.ajo.2016.04.011
Abulafia A, Hill WE, Franchina M, Barrett GD (2015) Comparison of methods to predict residual astigmatism after intraocular lens implantation. J Refract Surg 31:699–707. https://doi.org/10.3928/1081597X-20150928-03
doi: 10.3928/1081597X-20150928-03
Yang S, Byun YS, Kim HS, Chung SH (2021) Comparative accuracy of Barrett toric calculator with and without posterior corneal astigmatism measurements and the Kane toric formula. Am J Ophthalmol 231:48–57. https://doi.org/10.1016/j.ajo.2021.05.028
doi: 10.1016/j.ajo.2021.05.028
Lawless M, Jiang JY, Hodge C, Sutton G, Roberts TV, Barrett G (2020) Total keratometry in intraocular lens power calculations in eyes with previous laser refractive surgery. Clin Exp Ophthalmol 48:749–756. https://doi.org/10.1111/ceo.13760
doi: 10.1111/ceo.13760
Yeo TK, Heng WJ, Pek D, Wong J, Fam HB (2021) Accuracy of intraocular lens formulas using total keratometry in eyes with previous myopic laser refractive surgery. Eye (Lond) 35:1705–1711. https://doi.org/10.1038/s41433-020-01159-5
doi: 10.1038/s41433-020-01159-5
Savini G, Næser K, Schiano-Lomoriello D, Ducoli P (2017) Optimized keratometry and total corneal astigmatism for toric intraocular lens calculation. J Cataract Refract Surg 43:1140–1148. https://doi.org/10.1016/j.jcrs.2017.06.040
doi: 10.1016/j.jcrs.2017.06.040
Ferreira TB, Ribeiro P, Ribeiro FJ, O’Neill JG (2017) Comparison of methodologies using estimated or measured values of total corneal astigmatism for toric intraocular lens power calculation. J Refract Surg 33:794–800. https://doi.org/10.3928/1081597X-20171004-03
doi: 10.3928/1081597X-20171004-03
Savini G, Taroni L, Hoffer KJ (2020) Recent developments in intraocular lens power calculation methods—update 2020. Ann Transl Med 8:1553. https://doi.org/10.21037/atm-20-2290
doi: 10.21037/atm-20-2290
Fabian E, Wehner W (2019) Prediction accuracy of total keratometry compared to standard keratometry using different intraocular lens power formulas. J Refract Surg 35:362–368. https://doi.org/10.3928/1081597X-20190422-02
doi: 10.3928/1081597X-20190422-02
Srivannaboon S, Chirapapaisan C (2019) Comparison of refractive outcomes using conventional keratometry or total keratometry for IOL power calculation in cataract surgery. Graefes Arch Clin Exp Ophthalmol 257:2677–2682. https://doi.org/10.1007/s00417-019-04443-7
doi: 10.1007/s00417-019-04443-7
Turnbull AMJ, Barrett GD (2019) Using the first-eye prediction error in cataract surgery to refine the refractive outcome of the second eye. J Cataract Refract Surg 45:1239–1245. https://doi.org/10.1016/j.jcrs.2019.04.008
doi: 10.1016/j.jcrs.2019.04.008
Holladay JT (2004) Visual acuity measurements. J Cataract Refract Surg 30:287–290. https://doi.org/10.1016/j.jcrs.2004.01.014
doi: 10.1016/j.jcrs.2004.01.014
Næser K (2021) Surgically induced astigmatism made easy: calculating the surgically induced change in sphere and cylinder for corneal incisional, corneal laser, and intraocular lens-based surgery. J Cataract Refract Surg 47:118–122. https://doi.org/10.1097/j.jcrs.0000000000000518
doi: 10.1097/j.jcrs.0000000000000518
Hoffer KJ, Savini G (2021) Update on intraocular lens power calculation study protocols: the better way to design and report clinical trials. Ophthalmology 128:e115–e120. https://doi.org/10.1016/j.ophtha.2020.07.005
doi: 10.1016/j.ophtha.2020.07.005
Holladay JT, Wilcox RR, Koch DD, Wang L (2021) Review and recommendations for univariate statistical analysis of spherical equivalent prediction error for IOL power calculations. J Cataract Refract Surg 47:65–77. https://doi.org/10.1097/j.jcrs.0000000000000370
doi: 10.1097/j.jcrs.0000000000000370
Kieval JZ, Al-Hashimi S, Davidson RS et al (2020) Prevention and management of refractive prediction errors following cataract surgery. J Cataract Refract Surg 46:1189–1197. https://doi.org/10.1097/j.jcrs.0000000000000269
doi: 10.1097/j.jcrs.0000000000000269
Olsen T (1992) Sources of error in intraocular lens power calculation. J Cataract Refract Surg 18:125–129. https://doi.org/10.1016/s0886-3350(13)80917-0
doi: 10.1016/s0886-3350(13)80917-0
Kohnen S (2000) Postoperative refractive error resulting from incorrectly labeled intraocular lens power. J Cataract Refract Surg 26:777–778. https://doi.org/10.1016/s0886-3350(00)00373-4
doi: 10.1016/s0886-3350(00)00373-4
Savini G, Taroni L, Schiano-Lomoriello D, Hoffer KJ (2021) Repeatability of total keratometry and standard keratometry by the IOLMaster 700 and comparison to total corneal astigmatism by Scheimpflug imaging. Eye (Lond) 35:307–315. https://doi.org/10.1038/s41433-020-01245-8
doi: 10.1038/s41433-020-01245-8
Ryu S, Jun I, Kim TI, Seo KY, Kim EK (2021) Prediction accuracy of conventional and total keratometry for intraocular lens power calculation in femtosecond laser-assisted cataract surgery. Sci Rep 11:12869. https://doi.org/10.1038/s41598-021-92354-1
doi: 10.1038/s41598-021-92354-1
Chung HS, Chung JL, Kim YJ, Lee H, Kim JY, Tchah H (2021) Comparing prediction accuracy between total keratometry and conventional keratometry in cataract surgery with refractive multifocal intraocular lens implantation. Sci Rep 11:19234. https://doi.org/10.1038/s41598-021-98491-x
doi: 10.1038/s41598-021-98491-x

Auteurs

Yukitaka Danjo (Y)

Department of Ophthalmology, Osaka Minato Central Hospital, Japan Community Health Care Organization (JCHO), 1-7-1 Isoji, Minato-ku, Osaka, 552-0003, Japan. danjo@papa.email.ne.jp.

Reina Ohji (R)

Department of Ophthalmology, Osaka Minato Central Hospital, Japan Community Health Care Organization (JCHO), 1-7-1 Isoji, Minato-ku, Osaka, 552-0003, Japan.

Sayo Maeno (S)

Department of Ophthalmology, Osaka Minato Central Hospital, Japan Community Health Care Organization (JCHO), 1-7-1 Isoji, Minato-ku, Osaka, 552-0003, Japan.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH