Non-sterile gloves and dressing versus sterile gloves, dressings and drapes for suturing of traumatic wounds in the emergency department: a non-inferiority multicentre randomised controlled trial.
emergency department
wounds and injuries
Journal
Emergency medicine journal : EMJ
ISSN: 1472-0213
Titre abrégé: Emerg Med J
Pays: England
ID NLM: 100963089
Informations de publication
Date de publication:
09 2022
09 2022
Historique:
received:
07
04
2021
accepted:
04
07
2022
pubmed:
27
7
2022
medline:
26
8
2022
entrez:
26
7
2022
Statut:
ppublish
Résumé
Patients with traumatic wounds frequently present to the ED. Literature on whether to treat these wounds sterile or non-sterile is sparse. Non-sterile treatment has the advantage of saving resources and costs, and could be of value in health settings where sterile materials are not readily available. Our objective was to compare the rate of wound infection after suturing traumatic lacerations with non-sterile gloves and dressings versus sterile gloves, dressings and drapes in the ED. We hypothesised that non-sterile gloves and dressings would be non-inferior to sterile gloves, dressings and drapes. The non-inferiority margin was set at 2%. A multicentre single-blinded randomised controlled trial testing for non-inferiority of non-sterile gloves and dressings versus sterile gloves, dressings and drapes for suturing of traumatic wounds was performed in 3 EDs in The Netherlands. Adults with uncomplicated wounds were included from July 2012 to December 2016. At the time of treatment, patient and wound characteristics and management were documented. The outcome was wound infection, which was identified during follow-up in the treating ED at 5-14 days postprocedure. From 2468 eligible patients, 1480 were randomised in a sterile (n=747) or non-sterile (n=733) protocol. Baseline characteristics were similar in both study arms. The observed wound infection rate in the non-sterile group was 5.7% (95% CI 4.0% to 7.5%) vs 6.8% (95% CI 5.1% to 8.8%) in the sterile group. The mean difference of the wound infection rate of the two groups was -1.1% (95% CI -3.7% to 1.5%). Although recruitment ceased prior to reaching our planned sample size, the findings suggest that there is unlikely to be a large difference between the non-sterile gloves, dressings and sterile gloves, dressings and drapes for suturing of traumatic wounds in the ED. NL 34798.078.11, NTR3541.
Sections du résumé
BACKGROUND
Patients with traumatic wounds frequently present to the ED. Literature on whether to treat these wounds sterile or non-sterile is sparse. Non-sterile treatment has the advantage of saving resources and costs, and could be of value in health settings where sterile materials are not readily available. Our objective was to compare the rate of wound infection after suturing traumatic lacerations with non-sterile gloves and dressings versus sterile gloves, dressings and drapes in the ED. We hypothesised that non-sterile gloves and dressings would be non-inferior to sterile gloves, dressings and drapes. The non-inferiority margin was set at 2%.
METHODS
A multicentre single-blinded randomised controlled trial testing for non-inferiority of non-sterile gloves and dressings versus sterile gloves, dressings and drapes for suturing of traumatic wounds was performed in 3 EDs in The Netherlands. Adults with uncomplicated wounds were included from July 2012 to December 2016. At the time of treatment, patient and wound characteristics and management were documented. The outcome was wound infection, which was identified during follow-up in the treating ED at 5-14 days postprocedure.
RESULTS
From 2468 eligible patients, 1480 were randomised in a sterile (n=747) or non-sterile (n=733) protocol. Baseline characteristics were similar in both study arms. The observed wound infection rate in the non-sterile group was 5.7% (95% CI 4.0% to 7.5%) vs 6.8% (95% CI 5.1% to 8.8%) in the sterile group. The mean difference of the wound infection rate of the two groups was -1.1% (95% CI -3.7% to 1.5%).
CONCLUSION
Although recruitment ceased prior to reaching our planned sample size, the findings suggest that there is unlikely to be a large difference between the non-sterile gloves, dressings and sterile gloves, dressings and drapes for suturing of traumatic wounds in the ED.
TRIAL REGISTRATION NUMBER
NL 34798.078.11, NTR3541.
Identifiants
pubmed: 35882525
pii: emermed-2021-211540
doi: 10.1136/emermed-2021-211540
doi:
Types de publication
Journal Article
Multicenter Study
Randomized Controlled Trial
Langues
eng
Sous-ensembles de citation
IM
Pagination
650-654Commentaires et corrections
Type : CommentIn
Type : CommentIn
Informations de copyright
© Author(s) (or their employer(s)) 2022. No commercial re-use. See rights and permissions. Published by BMJ.
Déclaration de conflit d'intérêts
Competing interests: None declared.