Sensor-Augmented Insulin Pump with Predictive Low-Glucose Suspend (PLGS): Determining Optimal Settings of Pump and Sensor in a Multicenter Cohort of Patients with Type 1 Diabetes.
Hypo-minimizer
Predictive low-glucose suspend
Sensor-augmented pump
Type 1 diabetes
Journal
Diabetes therapy : research, treatment and education of diabetes and related disorders
ISSN: 1869-6953
Titre abrégé: Diabetes Ther
Pays: United States
ID NLM: 101539025
Informations de publication
Date de publication:
Sep 2022
Sep 2022
Historique:
received:
14
06
2022
accepted:
14
07
2022
pubmed:
2
8
2022
medline:
2
8
2022
entrez:
1
8
2022
Statut:
ppublish
Résumé
The use of predictive low-glucose suspend (PLGS) sensor-augmented pumps has been shown to lead to a significant reduction in hypoglycemic episodes in patients with type 1 diabetes (T1D), but their effects on hyperglycemia exposure are heterogeneous. The aim of this study was to determine the settings of the Medtronic 640G system to obtain the optimal balance between occurrence of both hypoglycemia and hyperglycemia. The hypo- and hyperglycemia area under the curve (AUC), as well as system settings [hypoglycemic threshold, mean insulin total daily dose (TDD), mean basal insulin percentage, and mean daily duration of PLGS] were collected between 2 and 12 times during 1 year in patients from four university hospital centers. Univariate/multivariate analyses and receiver operating characteristics (ROC) curves were performed to determine factors associated with hyper- and hypoglycemia AUC. A total of 864 observations were analyzed from 110 patients with T1D. Two preselected settings predictive of low hyperglycemia AUC were a basal insulin percentage < 52.0% [sensitivity (Se) = 0.66 and specificity (Sp) = 0.53] and a PLGS duration > 157.5 min/day (Se = 0.47 and Sp = 0.73). The preselected setting predictive of a low hypoglycemia AUC was a PLGS duration ≤ 174.4 min (Se = 0.83 and Sp = 0.51). Between-visit variation of PLGS and TDD was positively correlated (r = 0.61; p < 0.0001). The most important Medtronic 640G setting was the mean daily PLGS duration, where a value between 157.5 and 174.4 min/day was associated with the best reduction in both hypo- and hyperglycemia AUC. In this study, we showed that PLGS duration could be indirectly modified through total daily insulin dose adaptation. This study is registered in clinicaltrials.gov (NCT03047486).
Identifiants
pubmed: 35913656
doi: 10.1007/s13300-022-01302-3
pii: 10.1007/s13300-022-01302-3
pmc: PMC9399327
doi:
Banques de données
ClinicalTrials.gov
['NCT03047486']
Types de publication
Journal Article
Langues
eng
Pagination
1645-1657Informations de copyright
© 2022. The Author(s).
Références
Diabetol Int. 2019 Sep 16;11(2):97-104
pubmed: 32206479
Diabetes Care. 2017 Jun;40(6):764-770
pubmed: 28351897
Endocr Pract. 2020 Jul;26(7):714-721
pubmed: 33471639
Diabet Med. 2019 Sep;36(9):1100-1108
pubmed: 31134668
BMJ. 2018 Apr 18;361:k1310
pubmed: 29669716
Metabolism. 2019 Jan;90:20-30
pubmed: 30321535
Diabetes Care. 2021 Jan;44(Suppl 1):S85-S99
pubmed: 33298418
Diabetes Technol Ther. 2019 Sep;21(9):478-484
pubmed: 31329468
Diabetes Care. 2021 Jan;44(Suppl 1):S111-S124
pubmed: 33298420
Diabetes Technol Ther. 2012 Mar;14(3):225-31
pubmed: 22145851
J Diabetes Investig. 2020 Nov;11(6):1564-1569
pubmed: 32374513
Diabetes Care. 2018 Oct;41(10):2155-2161
pubmed: 30089663
Lancet Diabetes Endocrinol. 2017 Jul;5(7):501-512
pubmed: 28533136
Diabetes Technol Ther. 2017 Aug;19(8):446-456
pubmed: 28700272
Diabetes Care. 2018 Feb;41(2):303-310
pubmed: 29191844
Diabetes Technol Ther. 2018 Nov;20(11):738-743
pubmed: 30256132
Lancet Diabetes Endocrinol. 2019 Jun;7(6):462-472
pubmed: 31047902
Diabetes Technol Ther. 2016 May;18(5):288-91
pubmed: 26907513