Optimized Reconstruction Procedure of Photoacoustic Imaging for Reflection Artifacts Reduction.

artifact reduction image reconstruction photoacoustic imaging reflection artifacts signal processing

Journal

Ultrasonic imaging
ISSN: 1096-0910
Titre abrégé: Ultrason Imaging
Pays: England
ID NLM: 7909167

Informations de publication

Date de publication:
11 2022
Historique:
pubmed: 12 8 2022
medline: 5 10 2022
entrez: 11 8 2022
Statut: ppublish

Résumé

Photoacoustic (PA) imaging technology is of some value in medical diagnoses such as breast cancer detection, vasculature imaging, and surgery navigating. While as most imaging objects are bounded, the received RF signals consist of the direct-arrived signals (DAS) from the PA sources and the boundary-reflected signals (BRS). The undesired BRS will severely impair the quality during the image reconstruction. They will bring in many artifacts and confuse the actual shape and location of the PA sources. We improved the reconstruction procedure by removing the BRS before the regular reconstruction process to suppress those artifacts. To verify our proposed method, we compared the results of the conventional and optimized procedures experimentally. In terms of qualitative observation, the reconstructed images by the optimized procedure illustrate fewer artifacts and more accurate shapes of the PA sources. To quantitatively evaluate the traditional and the optimized imaging procedure, we calculated the Distribution Relative Error (DRE) between each experiment result and its standard drawing of the phantoms. For both phantoms and the ex-vivo sample, the DREs of reconstruction result by the optimized reconstruction procedure decrease significantly. The results suggest that the optimized reconstruction process can effectively suppress the reflection artifacts and improve the shape accuracy of the PA sources.

Identifiants

pubmed: 35950552
doi: 10.1177/01617346221116781
doi:

Types de publication

Journal Article Research Support, Non-U.S. Gov't

Langues

eng

Sous-ensembles de citation

IM

Pagination

204-212

Auteurs

Yuexin Qi (Y)

Institute of Applied Acoustics, School of Physics and Information Technology, Shaanxi Normal University, Xi'an, China.

Hui Cao (H)

Institute of Applied Acoustics, School of Physics and Information Technology, Shaanxi Normal University, Xi'an, China.

Guanjun Yin (G)

Institute of Applied Acoustics, School of Physics and Information Technology, Shaanxi Normal University, Xi'an, China.
MOE Key Laboratory of Modern Teaching Technology, Shaanxi Normal University, Xi'an, China.

Beilei Zhang (B)

Institute of Applied Acoustics, School of Physics and Information Technology, Shaanxi Normal University, Xi'an, China.

Jianzhong Guo (J)

Institute of Applied Acoustics, School of Physics and Information Technology, Shaanxi Normal University, Xi'an, China.

Articles similaires

Selecting optimal software code descriptors-The case of Java.

Yegor Bugayenko, Zamira Kholmatova, Artem Kruglov et al.
1.00
Software Algorithms Programming Languages
Humans Magnetic Resonance Imaging Phantoms, Imaging Infant, Newborn Signal-To-Noise Ratio
1.00
Humans Magnetic Resonance Imaging Brain Infant, Newborn Infant, Premature
Cephalometry Humans Anatomic Landmarks Software Internet

Classifications MeSH