Validation of a Sensor-Based Dynamic Ski Deflection Measurement in the Lab and Proof-of-Concept Field Investigation.
PyzoFlex
bending sensors
flexion
ski bending
ski deflection
Journal
Sensors (Basel, Switzerland)
ISSN: 1424-8220
Titre abrégé: Sensors (Basel)
Pays: Switzerland
ID NLM: 101204366
Informations de publication
Date de publication:
02 Aug 2022
02 Aug 2022
Historique:
received:
05
07
2022
revised:
27
07
2022
accepted:
29
07
2022
entrez:
12
8
2022
pubmed:
13
8
2022
medline:
16
8
2022
Statut:
epublish
Résumé
Introduction: Ski deflection is a performance-relevant factor in alpine skiing and the segmental and temporal curvature characteristics (m−1) along the ski have lately received particular attention. Recently, we introduced a PyzoFlex® ski deflection measurement prototype that demonstrated high reliability and validity in a quasi-static setting. The aim of the present work is to test the performance of an enhanced version of the prototype in a dynamic setting both in a skiing-like bending simulation as well as in a field proof-of-concept measurement. Material and methods: A total of twelve sensor foils were implemented on the upper surface of the ski. The ski sensors were calibrated with an empirical curvature model and then deformed on a programmable bending robot with the following program: 20 times at three different deformation velocities (vslow, vmedium, vfast) with (1) central bending, (2) front bending, (3) back bending, (4) edging left, and (5) edging right. For reliability assessment, pairs of bending cycles (cycle 1 vs. cycle 10 and cycle 10 vs. cycle 20) at vslow, vmedium, and vfast and between pairs of velocity (vslow vs. vmedium and vslow vs. vfast) were evaluated by calculating the change in the mean (CIM), coefficient of variation (CV) and intraclass correlation coefficient (ICC 3.1) with a 95% confidence interval. For validity assessment, the calculated segment-wise mean signals were compared with the values that were determined by 36 infrared markers that were attached to the ski using an optoelectrical measuring system (Qualisys). Results: High reliability was found for pairs of bending cycles (CIM −0.69−0.24%, max CV 0.28%, ICC 3.1 > 0.999) and pairs of velocities (max CIM = 3.03%, max CV = 3.05%, ICC 3.1 = 0.997). The criterion validity based on the Pearson correlation coefficient was r = 0.98. The accuracy (systematic bias) and precision (standard deviation), were −0.003 m−1 and 0.047 m−1, respectively. Conclusions: The proof-of-concept field measurement has shown that the prototype is stable, robust, and waterproof and provides characteristic curvature progressions with plausible values. Combined with the high laboratory-based reliability and validity of the PyzoFlex® prototype, this is a potential candidate for smart ski equipment.
Identifiants
pubmed: 35957325
pii: s22155768
doi: 10.3390/s22155768
pmc: PMC9371222
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Subventions
Organisme : Federal Ministry for Transport, Innovation and Technology
ID : 856255
Références
Front Sports Act Living. 2020 Mar 27;2:25
pubmed: 33345019
Sensors (Basel). 2021 Jul 16;21(14):
pubmed: 34300587
J Biomech. 2007;40(3):682-5
pubmed: 16580000
J Biomech. 2007;40(1):210-4
pubmed: 16376351
J Biomech. 2008 Aug 28;41(12):2776-80
pubmed: 18672241
Sensors (Basel). 2021 Dec 22;22(1):
pubmed: 35009590
J Chiropr Med. 2016 Jun;15(2):155-63
pubmed: 27330520
Stat Methods Med Res. 1999 Jun;8(2):135-60
pubmed: 10501650
Eur J Sport Sci. 2018 Jul;18(6):806-819
pubmed: 29741985
Sensors (Basel). 2014 Oct 03;14(10):18433-53
pubmed: 25285461