[Current developments in primary and secondary surgical treatment of midface and periorbital trauma].

Aktuelle Entwicklungen in der chirurgischen Primär- und Sekundärversorgung von Mittelgesichts- und periorbitalen Traumata.

Journal

HNO
ISSN: 1433-0458
Titre abrégé: HNO
Pays: Germany
ID NLM: 2985099R

Informations de publication

Date de publication:
Oct 2022
Historique:
accepted: 19 08 2022
pubmed: 1 9 2022
medline: 28 9 2022
entrez: 31 8 2022
Statut: ppublish

Résumé

Fractures of the periorbita and the midface are among the most common bony facial injuries. Aesthetic and functional reconstruction is a challenge in clinical routine. This article illustrates recent developments in the primary and secondary surgical treatment of midface and periorbital trauma. Resorbable patches and films increase the anatomic reconstructive capacity and enable treatment of extensive orbital fractures. Orbital fractures with involvement of supporting key structures are advantageously reconstructed using patient-specific implants (PSI), which are fabricated by computer-assisted manufacturing techniques and positioned by intraoperative navigation. If late complications such as bulbar malposition and enophthalmos have occurred after the initial procedure, they can be addressed by overcorrective restoration of orbital volume. The use of PSI for initial fracture restoration of the midface is not yet established but may be useful in re-osteotomies of misconsolidated fragments. Extensive midface defects with significant soft tissue involvement can be reconstructed using microvascular grafts. Consecutive reconstructive procedures may include orthognathic surgery and local flap reconstruction. In summary, the integration and advancement of computer-assisted techniques now offers individualized reconstruction procedures, which may be a viable alternative to conventional implants and compression miniplates. Future developments may focus on the search for innovative biomaterials, which can be integrated into computer-aided design and manufacturing processes. Frakturen der Periorbita und des Mittelgesichts gehören zu den häufigsten knöchernen Gesichtsverletzungen. Die ästhetische und funktionelle Rekonstruktion stellt eine Herausforderung im klinischen Alltag dar. Dieser Beitrag illustriert aktuelle Entwicklungen in der chirurgischen Primär- und Sekundärversorgung von Mittelgesichts- und periorbitalen Traumata. Resorbierbare Patches und Folien steigern die anatomische Rekonstruktionsfähigkeit und ermöglichen die Versorgung ausgedehnter Orbitafrakturen. Orbitafrakturen unter Beteiligung abstützender Leitstrukturen werden vorteilhaft mithilfe von patientenspezifischen Implantaten (PSI), die durch computergestützte Fertigungstechniken hergestellt und navigiert positioniert werden, rekonstruiert. Sind Spätkomplikationen wie Bulbusfehlstellungen und Enophthalmus nach dem ersten Eingriff aufgetreten, können diese durch eine überkorrigierende Wiederherstellung des orbitalen Volumens angegangen werden. Die Verwendung von PSI zur initialen Frakturversorgung des Mittelgesichts ist noch nicht etabliert, kann aber bei Reosteotomien fehlkonsolidierter Fragmente sinnvoll sein. Ausgedehnte Mittelgesichtsdefekte mit signifikanter Weichgewebebeteiligung können mithilfe mikrovaskulärer Transplantate rekonstruiert werden. Rekonstruktive Folgeeingriffe können orthognathe Korrekturen und lokale Lappenplastiken bedeuten. Letztlich bietet die Integration und Weiterentwicklung computergestützter Techniken heutzutage individualisierte Rekonstruktionsmöglichkeiten, die eine sinnvolle Alternative zu konventionellen Implantaten und Kompressionsminiplatten darstellen können. Zukünftige Entwicklungen fokussieren die Suche nach innovativen Biomaterialien, die in computergestützte Planungs- und Herstellungsprozesse integriert werden.

Autres résumés

Type: Publisher (ger)
Frakturen der Periorbita und des Mittelgesichts gehören zu den häufigsten knöchernen Gesichtsverletzungen. Die ästhetische und funktionelle Rekonstruktion stellt eine Herausforderung im klinischen Alltag dar. Dieser Beitrag illustriert aktuelle Entwicklungen in der chirurgischen Primär- und Sekundärversorgung von Mittelgesichts- und periorbitalen Traumata. Resorbierbare Patches und Folien steigern die anatomische Rekonstruktionsfähigkeit und ermöglichen die Versorgung ausgedehnter Orbitafrakturen. Orbitafrakturen unter Beteiligung abstützender Leitstrukturen werden vorteilhaft mithilfe von patientenspezifischen Implantaten (PSI), die durch computergestützte Fertigungstechniken hergestellt und navigiert positioniert werden, rekonstruiert. Sind Spätkomplikationen wie Bulbusfehlstellungen und Enophthalmus nach dem ersten Eingriff aufgetreten, können diese durch eine überkorrigierende Wiederherstellung des orbitalen Volumens angegangen werden. Die Verwendung von PSI zur initialen Frakturversorgung des Mittelgesichts ist noch nicht etabliert, kann aber bei Reosteotomien fehlkonsolidierter Fragmente sinnvoll sein. Ausgedehnte Mittelgesichtsdefekte mit signifikanter Weichgewebebeteiligung können mithilfe mikrovaskulärer Transplantate rekonstruiert werden. Rekonstruktive Folgeeingriffe können orthognathe Korrekturen und lokale Lappenplastiken bedeuten. Letztlich bietet die Integration und Weiterentwicklung computergestützter Techniken heutzutage individualisierte Rekonstruktionsmöglichkeiten, die eine sinnvolle Alternative zu konventionellen Implantaten und Kompressionsminiplatten darstellen können. Zukünftige Entwicklungen fokussieren die Suche nach innovativen Biomaterialien, die in computergestützte Planungs- und Herstellungsprozesse integriert werden.

Identifiants

pubmed: 36044058
doi: 10.1007/s00106-022-01226-1
pii: 10.1007/s00106-022-01226-1
doi:

Substances chimiques

Biocompatible Materials 0

Types de publication

Journal Article Review

Langues

ger

Sous-ensembles de citation

IM

Pagination

756-764

Informations de copyright

© 2022. The Author(s), under exclusive licence to Springer Medizin Verlag GmbH, ein Teil von Springer Nature.

Références

Aman H, Shokri T, Reddy LV et al (2019) Secondary management of midface fractures. Facial Plast Surg 35:640–644
pubmed: 31783421
Bicak A, Hale J, Day KM (2021) Bilateral orbital reconstruction with autologous bone graft after gunshot wound to upper midface. Cureus 13:e13611
pubmed: 33816010 pmcid: 8011473
Boffano P, Roccia F, Zavattero E et al (2015) European Maxillofacial Trauma (EURMAT) project: a multicentre and prospective study. J Craniomaxillofac Surg 43:62–70
pubmed: 25457465
Bonsembiante A, Valente L, Ciorba A et al (2019) Transnasal endoscopic approach for the treatment of medial orbital wall fractures. Ann Maxillofac Surg 9:411–414
pubmed: 31909026 pmcid: 6933993
Burnstine MA (2002) Clinical recommendations for repair of isolated orbital floor fractures: an evidence-based analysis. Ophthalmology 109:1207–1210
pubmed: 12093637
Costan VV, Nicolau A, Sulea D et al (2021) The impact of 3D technology in optimizing midface fracture treatment-focus on the zygomatic bone. J Oral Maxillofac Surg 79:880–891
pubmed: 33279472
Falkhausen R, Mitsimponas K, Adler W et al (2021) Clinical outcome of patients with orbital fractures treated with patient specific CAD/CAM ceramic implants—A retrospective study. J Craniomaxillofac Surg 49:468–479
pubmed: 33715966
Felix V, Veerasigamani N (2017) Endoscopic endonasal approach of blow out fracture reduction—A novel technique. J Clin Diagn Res 11:md6–md8
pubmed: 28892944 pmcid: 5583905
Gellrich NC, Eckstein FM, Lentge F et al (2021) Complex reconstructions in the facial and cranial regions. Unfallchirurg 124:807–816
pubmed: 34499183
Gellrich NC, Schramm A, Hammer B et al (2002) Computer-assisted secondary reconstruction of unilateral posttraumatic orbital deformity. Plast Reconstr Surg 110:1417–1429
pubmed: 12409759
Gooris PJJ, Muller BS, Dubois L et al (2017) Finding the ledge: Sagittal analysis of bony landmarks of the orbit. J Oral Maxillofac Surg 75:2613–2627
pubmed: 28822724
Hammer D, Vincent AG, Williams F et al (2021) Considerations in free flap reconstruction of the midface. Facial Plast Surg 37:759–770
pubmed: 33588473
Hölzle F, Swaid S, Schiwy T et al (2004) Versorgung von Jochbeinfrakturen über einen transkonjunktivalen Zugang mit lateraler Kanthotomie unter Schonung des lateralen Lidbandes. Oral Maxillofac Surg 8:296–301
Kanno T, Sukegawa S, Karino M et al (2019) Navigation-assisted orbital trauma reconstruction using a bioactive osteoconductive/bioresorbable u‑HA/PLLA system. J Maxillofac Oral Surg 18:329–338
pubmed: 31371870 pmcid: 6639503
Kesting MR, Hölzle F (2017) Traumatologie des Gesichtsschädels
Kim HI, Roh SG, Lee NH et al (2012) Giant maxillary mucocele occurring after reduction malarplasty. J Craniofac Surg 23:e123–e124
pubmed: 22446443
Kim YH, Park Y, Chung KJ (2016) Considerations for the management of medial orbital wall blowout fracture. Arch Plast Surg 43:229–236
pubmed: 27218019 pmcid: 4876150
Kittichokechai P, Sirichatchai K, Puncreobutr C et al (2022) A novel patient-specific titanium mesh implant design for reconstruction of complex orbital fracture. Plast Reconstr Surg Glob Open 10:e4081
pubmed: 35186634 pmcid: 8849307
Kruber D, Hierl T, Doerfler HM et al (2018) Preforming of polydioxanone sheets for orbital wall fractures—A technical note. J Craniomaxillofac Surg 46:1159–1161
pubmed: 29793778
Kühnel T (2020) The maxillary sinus via a prelacrimal approach as a gateway to the retromaxillary space and orbital floor. HNO 68:590–597
pubmed: 32405679
Luhr HG (1979) Stable fixation of maxillofacial fractures by means of mini-compression plates. Dtsch Zahnärztl Z 34:851
pubmed: 296720
Modabber A, Räsch M, Ghassemi M et al (2014) Noninvasive 3‑dimensional evaluation of periorbital asymmetry in isolated unilateral orbital floor fractures. Oral Surg Oral Med Oral Pathol Oral Radiol 118:392–399
pubmed: 25179129
Mok D, Lessard L, Cordoba C et al (2004) A review of materials currently used in orbital floor reconstruction. Can J Plast Surg 12:134–140
pubmed: 24115885 pmcid: 3792801
Pedemonte C, Muñoz T, Valenzuela K et al (2018) Reconstruction of medial orbital wall using a retrocaruncular approach. J Craniomaxillofac Surg 46:1726–1730
pubmed: 30170961
Pedemonte C, Sáez F, Vargas I et al (2016) Can customized implants correct enophthalmos and delayed diplopia in post-traumatic orbital deformities? A volumetric analysis. Int J Oral Maxillofac Surg 45:1086–1094
pubmed: 27157630
Peter KD, Richter WC, Seidl RO (1994) Esthetic incisions in traumatology involving the mid-face region. HNO 42:488–492
pubmed: 7960951
Seifert LB, Mainka T, Herrera-Vizcaino C et al (2021) Orbital floor fractures: epidemiology and outcomes of 1594 reconstructions. Eur J Trauma Emerg Surg 48:1427–1436
pubmed: 34128084 pmcid: 9001234
Shin J, Park SI, Hwang Y et al (2019) Reconstruction of medial wall blowout fracture defect with a combination of resorbable meshed plate and cancellous bone allograft. Biomed Res Int 2019:2656503
pubmed: 31737658 pmcid: 6815640
Shin JW, Lim JS, Yoo G et al (2013) An analysis of pure blowout fractures and associated ocular symptoms. J Craniofac Surg 24:703–707
pubmed: 23714863
Sigron GR, Barba M, Chammartin F et al (2021) Functional and cosmetic outcome after reconstruction of isolated, unilateral orbital floor fractures (blow-out fractures) with and without the support of 3D-printed orbital anatomical models. J Clin Med 10:3509
pubmed: 34441806 pmcid: 8397200
Sivam A, Enninghorst N (2022) The dilemma of reconstructive material choice for orbital floor fracture: a narrative review. Medicines (Basel) 9:6
Steinmassl O, Laimer J, Offermanns V et al (2020) Clinical Outcome Following Surgical Repair of Small Versus Large Orbital Floor Fractures Using Polyglactin 910/Polydioxanone (Ethisorb(®)). Materials (Basel) 13:206
Tang W, Guo L, Long J et al (2010) Individual design and rapid prototyping in reconstruction of orbital wall defects. J Oral Maxillofac Surg 68:562–570
pubmed: 20171476
Vasile VA, Istrate S, Iancu RC et al (2022) Biocompatible materials for orbital wall reconstruction—An overview. Materials (Basel) 15:2183
pmcid: 8954765
Welkoborsky HJ, Plontke SK (2018) Möglichkeiten des chirurgischen Zugangs zur Orbita. HNO 66:812–826
pubmed: 30306197
Yu J, Zhang J, Chen S et al (2021) Repair of unilateral combined orbital floor and medial wall fracture using two titanium mesh plates: a modified technique. Ann Transl Med 9:463
pubmed: 33850860 pmcid: 8039696
Zong CL, Shi YL, Jia JQ et al (2021) A retrospective study to compare the treatment outcomes with and without surgical navigation for fracture of the orbital wall. Chin J Traumatol 24:11–17
pubmed: 33246880

Auteurs

A Modabber (A)

Klinik und Poliklinik für Mund‑, Kiefer- und Gesichtschirurgie, Universitätsklinik RWTH Aachen, Pauwelsstr. 30, 52074, Aachen, Deutschland. amodabber@ukaachen.de.

P Winnand (P)

Klinik und Poliklinik für Mund‑, Kiefer- und Gesichtschirurgie, Universitätsklinik RWTH Aachen, Pauwelsstr. 30, 52074, Aachen, Deutschland.

F Hölzle (F)

Klinik und Poliklinik für Mund‑, Kiefer- und Gesichtschirurgie, Universitätsklinik RWTH Aachen, Pauwelsstr. 30, 52074, Aachen, Deutschland.

J Ilgner (J)

Klinik für Hals-Nasen-Ohren-Heilkunde, Kopf- und Hals-Chirurgie, Universitätsklinik RWTH Aachen, Aachen, Deutschland.

S Hackenberg (S)

Klinik für Hals-Nasen-Ohren-Heilkunde, Kopf- und Hals-Chirurgie, Universitätsklinik RWTH Aachen, Aachen, Deutschland.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH