Contraceptive efficacy and safety of the 52-mg levonorgestrel intrauterine system for up to 8 years: findings from the Mirena Extension Trial.

52-mg levonorgestrel-releasing intrauterine system Mirena Mirena Extension Trial Pearl Index contraceptive efficacy excessive uterine bleeding heavy menstrual bleeding intrauterine device levonorgestrel long-acting reversible contraception menorrhagia

Journal

American journal of obstetrics and gynecology
ISSN: 1097-6868
Titre abrégé: Am J Obstet Gynecol
Pays: United States
ID NLM: 0370476

Informations de publication

Date de publication:
12 2022
Historique:
received: 29 04 2022
revised: 25 08 2022
accepted: 03 09 2022
pubmed: 13 9 2022
medline: 26 1 2023
entrez: 12 9 2022
Statut: ppublish

Résumé

The 52-mg levonorgestrel-releasing intrauterine system is an established, long-acting contraceptive option with approved use for up to 7 years. The Mirena Extension Trial evaluated the efficacy and safety of the 52-mg levonorgestrel-releasing intrauterine system during extended use beyond 5 and up to 8 years. This was a multicenter, single-arm study in the United States, enrolling existing users of the 52-mg levonorgestrel-releasing intrauterine system, aged 18 to 35 years, who have had the system for 4.5 to 5 years. We assessed the contraceptive efficacy (Pearl Index) and cumulative failure rate (using the Kaplan-Meier method) of the 52-mg levonorgestrel-releasing intrauterine system during extended use. We also evaluated bleeding outcomes and adverse events. Of the 362 participants starting year 6, 243 entered and 223 completed 8 years of 52-mg levonorgestrel-releasing intrauterine system use. Just more than half the participants were parous. The mean (standard deviation) age was 29.2 (±2.9) years, and all participants were aged ≤36 years at the end of year 8. Two pregnancies occurred, both with the device in situ. The year 6 pregnancy was of undetermined location and resolved spontaneously. The pregnancy in year 7 was ectopic and resolved with methotrexate treatment. In both cases, the 52-mg levonorgestrel-releasing intrauterine system was removed and the participants left the trial. For years 6 to 8, the 3-year Pearl Index (95% confidence interval) was 0.28 (0.03-1.00) with a 3-year cumulative failure rate of 0.68% (0.17-2.71). Pearl Indexes for years 6, 7, and 8 were 0.34 (0.01-1.88), 0.40 (0.01-2.25), and 0.00 (0.00-1.90), respectively. The 3-year (years 6-8) ectopic pregnancy Pearl Index was 0.14 (0.00-0.77). We found treatment-emergent adverse events in 249 of 362 participants (68.8%), with 65 (18.0%) events considered to be related to the 52-mg levonorgestrel-releasing intrauterine system. The discontinuation rate was 38.4% (139/362), most commonly because of desire for pregnancy (12.2%, 44/362). During extended use beyond 5 years and up to 8 years, participants reported a decrease in the mean number of bleeding or spotting days with approximately half of the women experiencing amenorrhea or infrequent bleeding. We did not enroll a sufficient number of women using the 52-mg levonorgestrel-releasing intrauterine system for contraception and heavy menstrual bleeding to assess extended use for that indication. At the end of year 8, most (98.7%, 220/223) of the participants who completed the study remained satisfied with the continued use of the 52-mg levonorgestrel-releasing intrauterine system. Of the 31 women who discontinued early because of desire for pregnancy with evaluable data for return-to-fertility analysis, 24 reported a posttreatment pregnancy within 1 year, giving a 12-month return-to-fertility rate of 77.4%. The 52-mg levonorgestrel-releasing intrauterine system, initially approved for 5 years, maintains high contraceptive efficacy, user satisfaction, and a favorable safety profile through 8 years of use. Participants reported 26 posttreatment pregnancies in total, of which 24 occurred in women who had discontinued the 52-mg levonorgestrel-releasing intrauterine system because of a desire for pregnancy. Of note, among women who elected to continue use through 8 years, bleeding patterns remained highly favorable. These findings support continued 52-mg levonorgestrel-releasing intrauterine system use for up to 8 years in women who wish to continue treatment.

Sections du résumé

BACKGROUND
The 52-mg levonorgestrel-releasing intrauterine system is an established, long-acting contraceptive option with approved use for up to 7 years.
OBJECTIVE
The Mirena Extension Trial evaluated the efficacy and safety of the 52-mg levonorgestrel-releasing intrauterine system during extended use beyond 5 and up to 8 years.
STUDY DESIGN
This was a multicenter, single-arm study in the United States, enrolling existing users of the 52-mg levonorgestrel-releasing intrauterine system, aged 18 to 35 years, who have had the system for 4.5 to 5 years. We assessed the contraceptive efficacy (Pearl Index) and cumulative failure rate (using the Kaplan-Meier method) of the 52-mg levonorgestrel-releasing intrauterine system during extended use. We also evaluated bleeding outcomes and adverse events.
RESULTS
Of the 362 participants starting year 6, 243 entered and 223 completed 8 years of 52-mg levonorgestrel-releasing intrauterine system use. Just more than half the participants were parous. The mean (standard deviation) age was 29.2 (±2.9) years, and all participants were aged ≤36 years at the end of year 8. Two pregnancies occurred, both with the device in situ. The year 6 pregnancy was of undetermined location and resolved spontaneously. The pregnancy in year 7 was ectopic and resolved with methotrexate treatment. In both cases, the 52-mg levonorgestrel-releasing intrauterine system was removed and the participants left the trial. For years 6 to 8, the 3-year Pearl Index (95% confidence interval) was 0.28 (0.03-1.00) with a 3-year cumulative failure rate of 0.68% (0.17-2.71). Pearl Indexes for years 6, 7, and 8 were 0.34 (0.01-1.88), 0.40 (0.01-2.25), and 0.00 (0.00-1.90), respectively. The 3-year (years 6-8) ectopic pregnancy Pearl Index was 0.14 (0.00-0.77). We found treatment-emergent adverse events in 249 of 362 participants (68.8%), with 65 (18.0%) events considered to be related to the 52-mg levonorgestrel-releasing intrauterine system. The discontinuation rate was 38.4% (139/362), most commonly because of desire for pregnancy (12.2%, 44/362). During extended use beyond 5 years and up to 8 years, participants reported a decrease in the mean number of bleeding or spotting days with approximately half of the women experiencing amenorrhea or infrequent bleeding. We did not enroll a sufficient number of women using the 52-mg levonorgestrel-releasing intrauterine system for contraception and heavy menstrual bleeding to assess extended use for that indication. At the end of year 8, most (98.7%, 220/223) of the participants who completed the study remained satisfied with the continued use of the 52-mg levonorgestrel-releasing intrauterine system. Of the 31 women who discontinued early because of desire for pregnancy with evaluable data for return-to-fertility analysis, 24 reported a posttreatment pregnancy within 1 year, giving a 12-month return-to-fertility rate of 77.4%.
CONCLUSION
The 52-mg levonorgestrel-releasing intrauterine system, initially approved for 5 years, maintains high contraceptive efficacy, user satisfaction, and a favorable safety profile through 8 years of use. Participants reported 26 posttreatment pregnancies in total, of which 24 occurred in women who had discontinued the 52-mg levonorgestrel-releasing intrauterine system because of a desire for pregnancy. Of note, among women who elected to continue use through 8 years, bleeding patterns remained highly favorable. These findings support continued 52-mg levonorgestrel-releasing intrauterine system use for up to 8 years in women who wish to continue treatment.

Identifiants

pubmed: 36096186
pii: S0002-9378(22)00729-3
doi: 10.1016/j.ajog.2022.09.007
pii:
doi:

Substances chimiques

Levonorgestrel 5W7SIA7YZW
Contraceptive Agents, Female 0

Types de publication

Multicenter Study Journal Article Research Support, Non-U.S. Gov't Comment

Langues

eng

Sous-ensembles de citation

IM

Pagination

873.e1-873.e12

Commentaires et corrections

Type : CommentOn
Type : CommentIn

Informations de copyright

Copyright © 2022 The Authors. Published by Elsevier Inc. All rights reserved.

Auteurs

Jeffrey T Jensen (JT)

Department of Obstetrics and Gynecology, Oregon Health & Science University, Portland, OR. Electronic address: jensenje@ohsu.edu.

Eeva Lukkari-Lax (E)

Bayer Oy, Espoo, Finland.

Andrea Schulze (A)

Bayer AG, Berlin, Germany.

Yesmean Wahdan (Y)

Bayer US LLC, Whippany, NJ.

Marco Serrani (M)

Bayer AG, Berlin, Germany.

Robin Kroll (R)

Seattle Clinical Research Center, Seattle, WA.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH