Comparative study of two re-embedding methods on the ultrastructure of corneal tissue.
Cornea
Gap junctions
Pathology
Re-embedding
Transmission electron microscopy
Ultrastructure
Journal
Annals of anatomy = Anatomischer Anzeiger : official organ of the Anatomische Gesellschaft
ISSN: 1618-0402
Titre abrégé: Ann Anat
Pays: Germany
ID NLM: 100963897
Informations de publication
Date de publication:
Jan 2023
Jan 2023
Historique:
received:
13
03
2022
revised:
19
08
2022
accepted:
02
09
2022
pubmed:
5
10
2022
medline:
29
11
2022
entrez:
4
10
2022
Statut:
ppublish
Résumé
To expand the routine of pathological diagnostics of surgical keratoplasty specimens via transmission electron microscopy. The target was to identify the best re-embedding method for optimal structural preservation of formalin fixed paraffin embedded (FFPE) corneal tissue re-embedded into resin for ultrastructural analysis. Bovine FFPE corneal tissue was re-embedded into resin with either a rapid osmium-free four-hour-method or a four-day-routine-method known from nephropathology, compared with primary resin embedded bovine corneal tissue. The analysis involved the ultrastructure of cytoplasm, the intercellular interfaces of superficial epithelial cells, deepest basal epithelial cells and corneal endothelial cells, cell matrix interfaces, Bowman layer, corneal stroma, its microfibril bundles and Descemet membrane. The main observation was the equally reduced preservation status of re-embedded FFPE corneal tissue independent of the used re-embedding method. This extends to the intercellular contacts of superficial epithelial cells and the apical tight junctions of corneal endothelial cells. Hemidesmosomal cell matrix contacts showed less demarcation in re-embedded specimens. Cell matrix interfaces of Bowman layer and Descemet membrane were more clearly bordered in primary resin embedded than re-embedded tissue. In contrast, gap junctions in re-embedded tissue were detected in deepest basal epithelial cells and corneal endothelial cells with comparable preservation to primary resin embedding. Bowman layer, corneal stromal extracellular matrix, its microfibril bundles and Descemet membrane showed equal ultrastructural preservation in all evaluated methods. Corneal tissue can be successfully analysed with transmission electron microscopy after a rapid osmium-free four hour re-embedding procedure from FFPE material. A comparable morphology with primary resin embedded material can be obtained for gap junctions of deepest basal epithelial cells and corneal endothelial cells, further for Bowman layer, corneal stromal extracellular matrix, its microfibril bundles and Descemet membrane.
Identifiants
pubmed: 36195291
pii: S0940-9602(22)00116-9
doi: 10.1016/j.aanat.2022.152001
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
152001Informations de copyright
Copyright © 2022 Elsevier GmbH. All rights reserved.
Déclaration de conflit d'intérêts
Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.