Self-calibrated through-time spiral GRAPPA for real-time, free-breathing evaluation of left ventricular function.
GRAPPA
cardiovascular magnetic resonance
non-Cartesian
parallel imaging
real-time
spiral
Journal
Magnetic resonance in medicine
ISSN: 1522-2594
Titre abrégé: Magn Reson Med
Pays: United States
ID NLM: 8505245
Informations de publication
Date de publication:
02 2023
02 2023
Historique:
revised:
15
07
2022
received:
08
04
2022
accepted:
26
08
2022
pubmed:
6
10
2022
medline:
2
12
2022
entrez:
5
10
2022
Statut:
ppublish
Résumé
Through-time spiral GRAPPA is a real-time imaging technique that enables ungated, free-breathing evaluation of the left ventricle. However, it requires a separate fully-sampled calibration scan to calculate GRAPPA weights. A self-calibrated through-time spiral GRAPPA method is proposed that uses a specially designed spiral trajectory with interleaved arm ordering such that consecutive undersampled frames can be merged to form calibration data, eliminating the separate fully-sampled acquisition. The proposed method considers the time needed to acquire data at all points in a GRAPPA calibration kernel when using interleaved arm ordering. Using this metric, simulations were performed to design a spiral trajectory for self-calibrated GRAPPA. Data were acquired in healthy volunteers using the proposed method and a comparison electrocardiogram-gated and breath-held cine scan. Left ventricular functional values and image quality are compared. A 12-arm spiral trajectory was designed with a temporal resolution of 32.72 ms/cardiac phase with an acceleration factor of 3. Functional values calculated using the proposed method and the gold-standard method were not statistically significantly different (paired t-test, p < 0.05). Image quality ratings were lower for the proposed method, with statistically significantly different ratings (Wilcoxon signed rank test, p < 0.05) for two of five image quality aspects rated (level of artifact, blood-myocardium contrast). A self-calibrated through-time spiral GRAPPA reconstruction can enable ungated, free-breathing evaluation of the left ventricle in 71 s. Functional values are equivalent to a gold-standard cine technique, although some aspects of image quality may be inferior due to the real-time nature of the data collection.
Identifiants
pubmed: 36198001
doi: 10.1002/mrm.29462
pmc: PMC10092570
doi:
Types de publication
Journal Article
Research Support, U.S. Gov't, Non-P.H.S.
Research Support, N.I.H., Extramural
Langues
eng
Sous-ensembles de citation
IM
Pagination
536-549Subventions
Organisme : NHLBI NIH HHS
ID : R01 HL163030
Pays : United States
Organisme : NIH HHS
ID : F30CA239355
Pays : United States
Organisme : NCI NIH HHS
ID : F30 CA239355
Pays : United States
Organisme : NHLBI NIH HHS
ID : R01 HL163991
Pays : United States
Organisme : NHLBI NIH HHS
ID : R01 HL153034
Pays : United States
Organisme : NIH HHS
ID : T32GM07250
Pays : United States
Organisme : NIGMS NIH HHS
ID : T32 GM007250
Pays : United States
Organisme : NIH HHS
ID : R01HL153034
Pays : United States
Informations de copyright
© 2022 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine.
Références
J Cardiovasc Magn Reson. 2013 Sep 12;15:79
pubmed: 24028285
Magn Reson Med. 2023 Feb;89(2):536-549
pubmed: 36198001
NMR Biomed. 2011 Aug;24(7):844-54
pubmed: 21834008
Magn Reson Med. 2008 Dec;60(6):1457-65
pubmed: 19025911
NMR Biomed. 2010 Oct;23(8):986-94
pubmed: 20799371
Magn Reson Med. 2013 Jul;70(1):64-74
pubmed: 22887290
Magn Reson Imaging. 2014 Jul;32(6):747-58
pubmed: 24690453
Magn Reson Med. 2001 May;45(5):846-52
pubmed: 11323811
J Cardiovasc Magn Reson. 2020 Feb 24;22(1):17
pubmed: 32089132
Magn Reson Med. 2005 Apr;53(4):981-5
pubmed: 15799044
Magn Reson Med. 2017 Jan;77(1):250-264
pubmed: 26969611
Am J Cardiol. 2002 Jul 1;90(1):29-34
pubmed: 12088775
J Magn Reson Imaging. 2022 Jan;55(1):81-99
pubmed: 33295674
J Cardiovasc Magn Reson. 2015 May 21;17:37
pubmed: 25994390
J Cardiovasc Magn Reson. 2014 Oct 01;16:79
pubmed: 25315256
Lancet. 1986 Feb 8;1(8476):307-10
pubmed: 2868172
JAMA Netw Open. 2018 Aug 3;1(4):e181456
pubmed: 30646130
Magn Reson Med. 2019 Sep;82(3):1101-1112
pubmed: 31050011
J Cardiovasc Magn Reson. 2013 Jun 13;15:51
pubmed: 23763839
Magn Reson Med. 2020 May;83(5):1837-1850
pubmed: 31722128
J Am Coll Cardiol. 2013 May 28;61(21):2207-31
pubmed: 23500216
Magn Reson Med. 2011 Dec;66(6):1682-8
pubmed: 21523823
Magn Reson Med. 2003 Nov;50(5):1031-42
pubmed: 14587014
Magn Reson Med. 2019 Feb;81(2):1143-1156
pubmed: 30194880
J Cardiovasc Magn Reson. 2014 Sep 11;16:65
pubmed: 25231607
Magn Reson Med. 2011 Feb;65(2):492-505
pubmed: 20872865
Front Cardiovasc Med. 2020 Feb 25;7:17
pubmed: 32158767
Magn Reson Med. 2007 Jun;57(6):1075-85
pubmed: 17534921
Magn Reson Med. 2001 Oct;46(4):638-51
pubmed: 11590639
Magn Reson Med. 2007 May;57(5):931-8
pubmed: 17457884