The effect of Gaussian noise on pneumonia detection on chest radiographs, using convolutional neural networks.

Convolutional neural networks Deep learning Digital radiography Gaussian noise Pneumonia

Journal

Radiography (London, England : 1995)
ISSN: 1532-2831
Titre abrégé: Radiography (Lond)
Pays: Netherlands
ID NLM: 9604102

Informations de publication

Date de publication:
01 2023
Historique:
received: 16 03 2022
revised: 26 09 2022
accepted: 29 09 2022
pubmed: 25 10 2022
medline: 21 1 2023
entrez: 24 10 2022
Statut: ppublish

Résumé

Chest X-rays (CXR) with under-exposure increase image noise and this may affect convolutional neural network (CNN) performance. This study aimed to train and validate CNNs for classifying pneumonia on CXR as normal or pneumonia acquired at different image noise levels. The study used the curated and publicly available "Chest X-Ray Pneumonia" dataset of 5856 AP CXR classified into 1583 normal, 4273 viral and bacterial pneumonia cases. Gaussian noise with zero mean was added to the images, at 5 image noise variance levels, corresponding to decreasing exposure. Each noise-level dataset was split into 80% for training, 10% for validation, and 10% for test data and then classified using custom trained sequential CNN architecture. Six classification tasks were developed for five Gaussian noise levels and the original dataset. Sensitivity, specificity, predictive values and accuracy were used as evaluation performance metrics. CNN evaluation on the different datasets revealed no performance drop from the original dataset to the five datasets with different noise levels. Sensitivity, specificity and accuracy for the normal datasets were 98.7%, 76.1% and 90.2%. For the five Gaussian noise levels the sensitivity, specificity and accuracy ranged from 96.9% to 98.2%, 94.4%-98.7% and 96.8%-97.6%, respectively. A heat map was used for visual explanation of the CNNs. The CNNs sensitivity maintained, and the specificity increased in distinguishing between normal and pneumonia CXR with the introduction of image noise. No performance drops of CNNs in distinguishing cases with and without pneumonia CXR with different Gaussian noise levels was observed. This has potential for decreasing radiation dose to patients or maintaining exposure parameters for patients that require additional radiographs.

Identifiants

pubmed: 36274315
pii: S1078-8174(22)00144-4
doi: 10.1016/j.radi.2022.09.011
pii:
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

38-43

Informations de copyright

Copyright © 2022 The Author(s). Published by Elsevier Ltd.. All rights reserved.

Auteurs

M W Kusk (MW)

Department of Radiology and Nuclear Medicine, Hospital of South West Jutland, University Hospital of Southern Denmark, Esbjerg, Denmark.

S Lysdahlgaard (S)

Department of Radiology and Nuclear Medicine, Hospital of South West Jutland, University Hospital of Southern Denmark, Esbjerg, Denmark; Department of Regional Health Research, Faculty of Health Sciences, University of Southern Denmark, Odense, Denmark; Imaging Research Initiative Southwest (IRIS), Hospital of South West Jutland, University Hospital of Southern Denmark, Esbjerg, Denmark. Electronic address: Simon.Lysdahlgaard@rsyd.dk.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH