End-to-end test for lung SBRT: An Italian multicentric pilot experience.

End-to-end test Lung SBRT QA

Journal

Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)
ISSN: 1724-191X
Titre abrégé: Phys Med
Pays: Italy
ID NLM: 9302888

Informations de publication

Date de publication:
Dec 2022
Historique:
received: 29 01 2022
revised: 13 09 2022
accepted: 05 11 2022
pubmed: 20 11 2022
medline: 15 12 2022
entrez: 19 11 2022
Statut: ppublish

Résumé

Set up a lung SBRT end-to-end (e2e) test and perform a multicentre validation. A group of medical physicists from four hospitals and the Italian Institute of Ionizing Radiation Metrology designed the present e2e test. One sub-group set up the test, while another tested its feasibility and ease of use. A satisfaction questionnaire was used to collect user feedback. Each participating centre (PC) received the ADAM breathing phantom, a microDiamond detector and radiochromic films. Following the e2e protocol, each PC performed its standard internal procedure for simulating, planning, and irradiating the phantom. Each PC uploaded its planning and treatment delivery data in a shared Google Drive. A single centre analyzed all the data. The e2e test was successfully performed by all PCs. Participants' comments indicated that ADAM was well suited to the purpose and the protocol well described. All PCs performed the test in static and dynamic modes. The ratio between measured and planned point dose obtained by PC1, PC2, PC3, PC4 was: 0.99, 0.96, 1.01 and 1.01 (static track) and 0.99, 1.02, 1.01 and 0.94 (dynamic track). The gamma passing rates (3 % global, 3 mm) between planned and measured dose maps were 98.5 %, 94.0 %, 99.1 % and 94.0 % (static track) and 99.5 %, 96.5 %, 86.0 % and 94.5 % (dynamic track) for PC1, PC2, PC3 and PC4, respectively. An e2e test for lung SBRT has been proposed and tested in a multicentre framework. The results and user feedback prove the validity of the proposed e2e test.

Identifiants

pubmed: 36401941
pii: S1120-1797(22)02094-4
doi: 10.1016/j.ejmp.2022.11.004
pii:
doi:

Types de publication

Journal Article Multicenter Study

Langues

eng

Sous-ensembles de citation

IM

Pagination

129-135

Informations de copyright

Copyright © 2022 Associazione Italiana di Fisica Medica e Sanitaria. Published by Elsevier Ltd. All rights reserved.

Déclaration de conflit d'intérêts

Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Auteurs

S Pallotta (S)

Department of Biomedical, Experimental and Clinical Sciences "Mario Serio", University of Florence, Florence, Italy; Medical Physics Unit, AOU Careggi Florence, Italy. Electronic address: stefania.pallotta@unifi.it.

S Calusi (S)

Department of Biomedical, Experimental and Clinical Sciences "Mario Serio", University of Florence, Florence, Italy.

L Marrazzo (L)

Medical Physics Unit, AOU Careggi Florence, Italy.

C Talamonti (C)

Department of Biomedical, Experimental and Clinical Sciences "Mario Serio", University of Florence, Florence, Italy; Medical Physics Unit, AOU Careggi Florence, Italy.

S Russo (S)

Health Physics Unit, Azienda USL Toscana Centro Florence, Italy.

M Esposito (M)

Health Physics Unit, Azienda USL Toscana Centro Florence, Italy.

C Fiandra (C)

Oncology Department, University of Tourin, Tourin, Italy.

F R Giglioli (FR)

Health Physics Unit A. O. Città della Salute e della Scienza di Torino P.O. Molinette, Tourin, Italy.

M Pimpinella (M)

National Institute of Ionizing Radiation Metrology, ENEA-INMRI, Rome, Italy.

V De Coste (V)

National Institute of Ionizing Radiation Metrology, ENEA-INMRI, Rome, Italy.

A Bruschi (A)

Medical Physics Unit San Rossore, Pisa, Italy.

S Barbiero (S)

Medical Physics Unit San Rossore, Pisa, Italy.

P Mancosu (P)

IRCCS Humanitas Research Hospital, Rozzano (MI), Italy.

M Stasi (M)

Health Physics - AO Ordine Mauriziano, Tourin, Italy.

R Lisci (R)

Department of Agricultural, Food and Forestry System, University of Florence, Florence, Italy.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH