Résumé
The objective of the study was to restore Tc-99m methylene diphosphonate (MDP) bone scan image using blind deconvolution (BD) algorithm so that ribs, vertebrae, and lesions present in them become prominent. Our study consists of retrospective data in which 356 Tc-99m MDP bone scan images (178 anterior and 178 posterior) were processed using dynamic stochastic resonance algorithm, block-matching 3D filter, and then restored using BD algorithm. Two nuclear medicine (NM) physicians compared restored image with its input image; they especially lookedfor: (a) improvement in lesions detectability, (b) artifacts if any, (c) deterioration in ribs and vertebra, and (d) contrast enhancement in adjacent vertebra and adjacent ribs. They selected one out of two (restored and input) images, which had better quality. The overall image quality was also assessed using the following image quality metrics: brightness, blur, global contrast factor, and contrast per pixel. The Wilcoxon signed-rank test was applied for finding significant difference between the value of image quality metrics of restored image and input image at level of significance alpha = 0.05. According to NM physicians, 80.3% (286 out of 356) of restored images were acceptable, whereas 19.6% (70 out of 356) were unacceptable. Ribs and vertebrae were prominent in 161 out of 178 posterior restored images. Lumbar vertebrae were enhanced and well differentiated from adjacent vertebrae in 125 out of 178 anterior restored images. The value of image quality metrics of restored and input images were found to be significantly different ( P -value < 0.0001). Ribs, vertebrae, and lesions present in them become prominent in the most of Tc-99m MDP bone scan images (80.3%) restored using BD algorithm.
Identifiants
pubmed: 36437541
doi: 10.1097/MNM.0000000000001642
pii: 00006231-202301000-00004
doi:
Substances chimiques
Technetium Tc 99m Medronate
X89XV46R07
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
27-37Informations de copyright
Copyright © 2022 Wolters Kluwer Health, Inc. All rights reserved.
Références
Shah L, Salzman K. Imaging of spinal metastatic disease. Int J Surg Oncol 2011: 1–12.
Even-Sapir E, Metser U, Mishani E, Lievshitz G, Lerman H, Leibovitch I. The detection of bone metastases in patients with high-risk prostate cancer: 99mTc-MDP planar bone scintigraphy, single- and multi-field-of-view SPECT, 18F-fluoride PET, and 18F-fluoride PET/CT. J Nucl Med 2006; 47:287–297.
Naddaf SY, Collier BD, Elgazzar AH, Khalil MM. Technical errors in planar bone scanning. J Nucl Med Technol 2004; 32:148–153.
Satish P, Srikantaswamy M, Ramaswamy NK. A comprehensive review of blind deconvolution techniques for image deblurring. Trait Signal 2020; 37:527–539.
Kundur D, Hatzinakos D. Blind image deconvolution revisited. IEEE Signal Process Mag 1996; 13:61–63.
Chowdhury MR, Qin J, Lou Y. Non-blind and blind deconvolution under poisson noise using fractional-order total variation. J Math Imaging Vis 2020; 62:1238–1255.
Fish DA, Brinicombe AM, Pike ER, Walker JG. Blind deconvolution by means of the Richardson–Lucy algorithm. JOSA A 1995; 12:58–65.
Benzi R, Sutera A, Vulpiani A. The mechanism of stochastic resonance. J Phys 1981; 14:L453–L457.
Jha RK, Chouhan R. ‘Noise-induced contrast enhancement using stochastic resonance on singular values’. Signal Image Video Process 2012:1–9.
Dabov K, Foi A, Katkovnik V, Egiazarian K. Image denoising by sparse 3-D transform-domain collaborative filtering. IEEE Trans Image Process 2007; 16:2080–2095.
Gonzalez RC, Eddins SL, Woods RE. Image restoration and reconstruction. In: Digital image publishing using MATLAB. Tata McGraw Hill Education Private Limited; 2010. pp. 163–231.
Jayaraman S, Esakkirajn S, Veerakumar T. Image restoration and denoising, In: Digital image processing. McGraw Hill education (India) Private Limited; 2013. pp. 324–367.
https://in.mathworks.com/help/images/deblurring-images-using-the-blind-deconvolution-algorithm.html . [Accessed 25 August 2022]
Pandey AK, Sonker D, Chaudhary J, Jaleel J, Baghel V, Sharma PD, et al. Restoration of Tc-99m methyl diphosphonate bone scan image using Richardson-Lucy algorithm. Nucl Med Commun 2022; 43:518–528.
Simonotto E, Riani M, Seife C, Roberts M, Twitty J, Moss F. Visual perception of stochastic resonance. Phys Rev Lett 1997; 78:1186–1189.
Matkovic K, Neumann L, Neumann A, Psik T, Purgathofer W. Global contrast factor-a new approach to image contrast. In: InCAe: Eurographics Workshop on Computational Aesthetics in Graphics, Visualization and Imaging 2005; 18–20 May 2005; Girona, Spain: The Eurographics Association; 2005.pp. 159–167.
Crete F, Dolmiere T, Ladret P, Nicolas M. The blur effect: perception and estimation with a new no-reference perceptual blur metric. In: Human vision and electronic imaging XII. International Society for Optics and Photonics; 2007. Vol. 6492, p. 64920I.
Eramian M, Mould D. Histogram equalization using neighborhood metrics. In: The 2nd Canadian Conference on Computer and Robot Vision (CRV’05); IEEE; 2005. pp. 397–404.
R Core Team. R: A language and environment for statistical computing . R Foundation for Statistical Computing; 2018. https://www.R-project.org/ .
Pandey AK, Santosh Y, Sharma PD, Yadav D, Bal C, Kumar R. Restoration of I-131 whole body image using a Wiener filter. Nucl Med Commun 2020; 41:426–435.
Sutton DG, Kempi V. Constrained least-squares restoration and renogram deconvolution: a comparison by simulation. Phys Med Biol 1992; 37:53–67.
King MA, Doherty PW, Schwinger RB, Penney BC. A Wiener filter for nuclear medicine images. Med Phys 1983; 10:876–880.
King MA, Schwinger RB, Doherty PW, Penney BC. Two-dimensional filtering of SPECT images using the Metz and Wiener filters. J Nucl Med 1984; 25:1234–1240.
King MA, Schwinger RB, Penney BC. Variation of the count-dependent Metz filter with imaging system modulation transfer function. Med Phys 1986; 13:139–149.
Hon TC, Rangayyan RM, Hahn LJ, Kloiber R. Restoration of gamma camera-based nuclear medicine images. IEEE Trans Med Imaging 1989; 8:354–363.
Raff U, Stroud DN, Hendee WR. Improvement of lesion detection in scintigraphic images by SVD techniques for resolution recovery. IEEE Trans Med Imaging 1986; 5:35–44.
Mignotte M, Meunier J. Three-dimensional blind deconvolution of SPECT images. IEEE Trans Biomed Eng 2000; 47:274–280.