Midterm Results of Physician-Modified Stent Grafts for Thoracoabdominal and Complex Abdominal Aortic Aneurysms Repair.
Humans
Middle Aged
Aged
Aged, 80 and over
Aortic Aneurysm, Abdominal
/ diagnostic imaging
Blood Vessel Prosthesis
Blood Vessel Prosthesis Implantation
Stents
Aortic Aneurysm, Thoracic
/ diagnostic imaging
Retrospective Studies
Risk Factors
Treatment Outcome
Prosthesis Design
Time Factors
Endovascular Procedures
Aortic Aneurysm, Thoracoabdominal
Journal
Annals of vascular surgery
ISSN: 1615-5947
Titre abrégé: Ann Vasc Surg
Pays: Netherlands
ID NLM: 8703941
Informations de publication
Date de publication:
Jul 2023
Jul 2023
Historique:
received:
01
06
2022
revised:
28
10
2022
accepted:
07
11
2022
medline:
19
6
2023
pubmed:
3
12
2022
entrez:
2
12
2022
Statut:
ppublish
Résumé
To assess midterm results of physician-modified stent grafts (PMSG) for the treatment of emergent complex abdominal and thoracoabdominal aortic aneurysms (TAAA) in high-risk patients. All consecutive patients with emergent complex abdominal or TAAA undergoing PMSG technique between January 2012 and July 2019 were retrospectively included. Indications for PMSG were symptomatic aneurysms and rapidly growing aneurysms >70 mm. Ruptured aneurysms were excluded. Thirty-three patients (mean age: 74 +/- 11 years) were included. The mean aneurysm diameter was 76 +- 20 mm. Patients presented with TAAA (n = 20, 61%), complex abdominal aortic aneurysms (CAAA, n = 9, 27%), type I endoleak after previous endovascular aneurysm repair (n = 3, 9%) and intramural aortic hematoma (n = 1, 3%). Chimney technique was performed in addition to PMSG in seven cases (21%). Intraoperative adverse events were recorded in seven cases (35%) in the TAAA group and one case (11%) in the CAAA group. In-hospital mortality rate was 15% (n = 3) in the TAAA group and 11% (n = 1) in the CAAA group. Moderate to severe complications were recorded in 45% of cases (n = 15). Spinal cord ischemia occurred in two cases (6%, one case without residual deficit and one with minor motor deficit). One (3%) patient required transient hemodialysis. One patient presented with early aortic rupture and required an open conversion. The mean follow-up duration was 31 months (1-79). Overall survival estimates were 81.4% (95% confidence interval [CI]: 63.1.-91.2) at 1 year and 71.6% (95% CI: 52.6-84.1) at 2 years. Freedom from reintervention rates at 1 and 2 years were 61.2% (95% CI: 41.7-75.9) and 57.4% (95% CI: 37.9-72.8). Target vessel primary patency rates at 1 and 2 years were 99.2% (95% CI: 94.2-99.9) and 97.7% (95% CI: 90.7-99.4). PMSG for high-risk patients with complex aneurysms provided acceptable technical success and excellent target vessel patency rates but were associated with a 12% in-hospital mortality rate. Reinterventions were frequent. This technique should be limited to selected high-risk patients for whom the risk of rupture in the short-term is deemed too high to wait for graft manufacturing of custom-made device.
Sections du résumé
BACKGROUND
BACKGROUND
To assess midterm results of physician-modified stent grafts (PMSG) for the treatment of emergent complex abdominal and thoracoabdominal aortic aneurysms (TAAA) in high-risk patients.
METHODS
METHODS
All consecutive patients with emergent complex abdominal or TAAA undergoing PMSG technique between January 2012 and July 2019 were retrospectively included. Indications for PMSG were symptomatic aneurysms and rapidly growing aneurysms >70 mm. Ruptured aneurysms were excluded.
RESULTS
RESULTS
Thirty-three patients (mean age: 74 +/- 11 years) were included. The mean aneurysm diameter was 76 +- 20 mm. Patients presented with TAAA (n = 20, 61%), complex abdominal aortic aneurysms (CAAA, n = 9, 27%), type I endoleak after previous endovascular aneurysm repair (n = 3, 9%) and intramural aortic hematoma (n = 1, 3%). Chimney technique was performed in addition to PMSG in seven cases (21%). Intraoperative adverse events were recorded in seven cases (35%) in the TAAA group and one case (11%) in the CAAA group. In-hospital mortality rate was 15% (n = 3) in the TAAA group and 11% (n = 1) in the CAAA group. Moderate to severe complications were recorded in 45% of cases (n = 15). Spinal cord ischemia occurred in two cases (6%, one case without residual deficit and one with minor motor deficit). One (3%) patient required transient hemodialysis. One patient presented with early aortic rupture and required an open conversion. The mean follow-up duration was 31 months (1-79). Overall survival estimates were 81.4% (95% confidence interval [CI]: 63.1.-91.2) at 1 year and 71.6% (95% CI: 52.6-84.1) at 2 years. Freedom from reintervention rates at 1 and 2 years were 61.2% (95% CI: 41.7-75.9) and 57.4% (95% CI: 37.9-72.8). Target vessel primary patency rates at 1 and 2 years were 99.2% (95% CI: 94.2-99.9) and 97.7% (95% CI: 90.7-99.4).
CONCLUSIONS
CONCLUSIONS
PMSG for high-risk patients with complex aneurysms provided acceptable technical success and excellent target vessel patency rates but were associated with a 12% in-hospital mortality rate. Reinterventions were frequent. This technique should be limited to selected high-risk patients for whom the risk of rupture in the short-term is deemed too high to wait for graft manufacturing of custom-made device.
Identifiants
pubmed: 36460175
pii: S0890-5096(22)00762-2
doi: 10.1016/j.avsg.2022.11.015
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
38-47Informations de copyright
Copyright © 2022 Elsevier Inc. All rights reserved.