Pulsed Electric Field Ablation of Epicardial Autonomic Ganglia: Computer Analysis of Monopolar Electric Field across the Tissues Involved.
cardiac arrhythmia
computer modelling
epicardial ablation
ganglionated plexi
pulsed field ablation
Journal
Bioengineering (Basel, Switzerland)
ISSN: 2306-5354
Titre abrégé: Bioengineering (Basel)
Pays: Switzerland
ID NLM: 101676056
Informations de publication
Date de publication:
27 Nov 2022
27 Nov 2022
Historique:
received:
19
10
2022
revised:
09
11
2022
accepted:
23
11
2022
entrez:
23
12
2022
pubmed:
24
12
2022
medline:
24
12
2022
Statut:
epublish
Résumé
Pulsed Electric Field (PEF) ablation has been proposed as a non-thermal energy to treat atrial fibrillation (AF) by epicardial ablation of ganglionated plexi (GP), which are embedded within epicardial fat. Our objective was to study the distribution of the electric field through the involved tissues (fat, GPs, myocardium and blood) during epicardial PEF ablation. A two-dimensional model was built considering different tissue layers below the ablation device which consists of an irrigated electrode. The 1000 V/cm threshold was used to estimate the 'PEF-zone'. The PEF-zone was almost 100% circumscribed in the epicardial fat layer, with very little incidence in the myocardium. The presence of the saline on the epicardial fat causes the PEF-zone to spread laterally around the electrode from ~5 mm to ~15 mm, relatively independently of how embedded the electrode is in the saline layer. For a saline layer well spread over the tissue surface and an electrode fully embedded in the saline layer, the PEF-zone width decreases as the fat layer thickens: from ~15 mm for fat thickness of 1 and 2 mm, down to ~10 mm for fat thickness of 5 mm. The presence of a GP in the center of the fat layer hardly affects the size of the PEF-zone, but significantly alters the distribution of the electric field around the GP, resulting in progressively lower values than in the surrounding adipose tissue as the fat layer thickness increased. Our results suggest how some procedural (irrigation) and anatomical parameters (fat thicknesses and presence of GPs) could be relevant in terms of the size of the tissue area affected by pulsed field ablation.
Sections du résumé
BACKGROUND AND OBJECTIVES
OBJECTIVE
Pulsed Electric Field (PEF) ablation has been proposed as a non-thermal energy to treat atrial fibrillation (AF) by epicardial ablation of ganglionated plexi (GP), which are embedded within epicardial fat. Our objective was to study the distribution of the electric field through the involved tissues (fat, GPs, myocardium and blood) during epicardial PEF ablation.
METHODS
METHODS
A two-dimensional model was built considering different tissue layers below the ablation device which consists of an irrigated electrode. The 1000 V/cm threshold was used to estimate the 'PEF-zone'.
RESULTS
RESULTS
The PEF-zone was almost 100% circumscribed in the epicardial fat layer, with very little incidence in the myocardium. The presence of the saline on the epicardial fat causes the PEF-zone to spread laterally around the electrode from ~5 mm to ~15 mm, relatively independently of how embedded the electrode is in the saline layer. For a saline layer well spread over the tissue surface and an electrode fully embedded in the saline layer, the PEF-zone width decreases as the fat layer thickens: from ~15 mm for fat thickness of 1 and 2 mm, down to ~10 mm for fat thickness of 5 mm. The presence of a GP in the center of the fat layer hardly affects the size of the PEF-zone, but significantly alters the distribution of the electric field around the GP, resulting in progressively lower values than in the surrounding adipose tissue as the fat layer thickness increased.
CONCLUSIONS
CONCLUSIONS
Our results suggest how some procedural (irrigation) and anatomical parameters (fat thicknesses and presence of GPs) could be relevant in terms of the size of the tissue area affected by pulsed field ablation.
Identifiants
pubmed: 36550937
pii: bioengineering9120731
doi: 10.3390/bioengineering9120731
pmc: PMC9774172
pii:
doi:
Types de publication
Journal Article
Langues
eng
Subventions
Organisme : Government of Ireland
ID : DT20180123
Références
Heart Rhythm. 2005 Jun;2(6):624-31
pubmed: 15922271
IEEE Trans Biomed Eng. 2005 May;52(5):816-27
pubmed: 15887531
Anat Rec. 1997 Feb;247(2):289-98
pubmed: 9026008
J Clin Med. 2020 Sep 24;9(10):
pubmed: 32987820
Lasers Surg Med. 2015 Feb;47(2):183-95
pubmed: 25651998
J Cardiovasc Electrophysiol. 2022 Sep;33(9):2050-2061
pubmed: 35924470
Phys Med Biol. 2009 Aug 21;54(16):4863-78
pubmed: 19636081
Comput Methods Programs Biomed. 2022 Jun;221:106886
pubmed: 35597202
Heart Rhythm. 2011 Sep;8(9):1404-10
pubmed: 21699839
Circ Arrhythm Electrophysiol. 2021 Sep;14(9):e010086
pubmed: 34538095
J Cardiovasc Electrophysiol. 2021 Apr;32(4):958-969
pubmed: 33650743
J Cardiovasc Dev Dis. 2022 Mar 24;9(4):
pubmed: 35448071
J Cardiovasc Electrophysiol. 2019 Apr;30(4):607-615
pubmed: 30680839
Pacing Clin Electrophysiol. 2016 May;39(5):407-17
pubmed: 26854009