Conservation of pyramidal tract in radiosurgery for brain metastases of lung adenocarcinoma: Three-dimensional analysis of biologically effective dose.
Biologically effective dose
Brain metastases
Motor function
Pyramidal tract
Stereotactic radiosurgery
Three-dimensionalmodel
Journal
Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology
ISSN: 1879-0887
Titre abrégé: Radiother Oncol
Pays: Ireland
ID NLM: 8407192
Informations de publication
Date de publication:
02 2023
02 2023
Historique:
received:
15
08
2022
revised:
13
12
2022
accepted:
16
12
2022
pubmed:
1
1
2023
medline:
3
3
2023
entrez:
31
12
2022
Statut:
ppublish
Résumé
Gamma knife surgery (GKS) for brain metastases (BMs) adjacent to the pyramidal tract (PT) is still a challenge to conduct. PT visualization and biologically effective dose (BED) calculation on a voxel-by-voxel basis may provide data to establish clinically safe values. We aimed to assess the relationship of parameters extracted from the BED-volume histogram with outcomes of PT after GKS-treating target (adjacent BM of lung adenocarcinoma). We formed BED-volume histograms for 672 BMs in a retrospective cohort, using 3-dimensional (3D) coordinate values of PT, target, and each iso-centre to calculate the 3D BED distribution in a 200 × 200 × 200 matrix. PT conservation failure (PTCF) was judged clinically and radiologically and classified as lesion progression and radionecrosis. Cox proportional hazards models were used to analyse 3D BED parameters. Internal validation of models was performed by bootstrapping. There were 116 (17.3 %) subjects with PTCF in the cohort, of which 74 (11.0 %) and 42 (6.3 %) were caused by lesion progression and radionecrosis, respectively. Multivariate analysis showed that D The conservation of PT in GKS for BMs of lung adenocarcinoma depends on the combination of PT-tolerated BED and target effective control BED. Therefore, a BED-volume histogram with a 3D BED algorithm is proposed to assess plan quality.
Sections du résumé
BACKGROUND
Gamma knife surgery (GKS) for brain metastases (BMs) adjacent to the pyramidal tract (PT) is still a challenge to conduct. PT visualization and biologically effective dose (BED) calculation on a voxel-by-voxel basis may provide data to establish clinically safe values. We aimed to assess the relationship of parameters extracted from the BED-volume histogram with outcomes of PT after GKS-treating target (adjacent BM of lung adenocarcinoma).
METHODS
We formed BED-volume histograms for 672 BMs in a retrospective cohort, using 3-dimensional (3D) coordinate values of PT, target, and each iso-centre to calculate the 3D BED distribution in a 200 × 200 × 200 matrix. PT conservation failure (PTCF) was judged clinically and radiologically and classified as lesion progression and radionecrosis. Cox proportional hazards models were used to analyse 3D BED parameters. Internal validation of models was performed by bootstrapping.
RESULTS
There were 116 (17.3 %) subjects with PTCF in the cohort, of which 74 (11.0 %) and 42 (6.3 %) were caused by lesion progression and radionecrosis, respectively. Multivariate analysis showed that D
CONCLUSIONS
The conservation of PT in GKS for BMs of lung adenocarcinoma depends on the combination of PT-tolerated BED and target effective control BED. Therefore, a BED-volume histogram with a 3D BED algorithm is proposed to assess plan quality.
Identifiants
pubmed: 36586589
pii: S0167-8140(22)04603-5
doi: 10.1016/j.radonc.2022.109451
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
109451Informations de copyright
Copyright © 2022 Elsevier B.V. All rights reserved.
Déclaration de conflit d'intérêts
Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.