Imprecise prediction of implant sizes with preoperative 2D digital templating in total knee arthroplasty.
Accuracy
Digital templating
EndoCert
Operative time
Storage cost
Total knee arthroplasty
Journal
Archives of orthopaedic and trauma surgery
ISSN: 1434-3916
Titre abrégé: Arch Orthop Trauma Surg
Pays: Germany
ID NLM: 9011043
Informations de publication
Date de publication:
Aug 2023
Aug 2023
Historique:
received:
10
06
2022
accepted:
07
01
2023
medline:
31
7
2023
pubmed:
18
1
2023
entrez:
17
1
2023
Statut:
ppublish
Résumé
To analyze the match between preoperatively determined implant size (2D templating) and intraoperatively used implant size in total knee arthroplasty (TKA). Also examined were the factors that might influence templating accuracy (gender, surgeon experience, obesity, etc.). The study was retrospective and conducted in a specialized ENDOCERT arthroplasty center. Digital templating was done with the MediCAD software. If the planned and implanted TKA components (both femur and tibia) were the same size, the match was classified "exact." A deviation of ± one size (at the femur or tibia or both) was classified "accurate." A deviation of ± two or more sizes (at the femur or tibia or both) was classified "inaccurate." Obesity, gender, implant type and surgeon experience were investigated for potential influence on templating accuracy. Chi-square tests and Cohen's weighted kappa test were used for statistical analysis. A total of 482 cases [33.6% male, 66.4% female, age 69 ± 11, body mass index (BMI) 30.3 ± 5.8] were included. When the femur and tibia were taken together, exact size match was observed in 34% (95% CI 29.9-38.3%) of cases, accurate size match in 57.5% (95% CI 53-61.8%) and inaccurate size match in 8.5% (95% CI 6.3-11.2%). Inaccurate size match prolonged operative time (p = 0.028). Regarding the factors potentially influencing templating accuracy, only gender had a significant influence, with templating being more accurate in men (p = 0.004). BMI had no influence on accuracy (p = 0.87). No effect on accuracy was observed for implant type and surgeon experience. The accuracy of 2D size templating in TKA is low, even in a specialized ENDOCERT arthroplasty center. The study findings challenge the usefulness of preoperative 2D size templating and highlight the importance of more reliable templating methods. Level III (retrospective observational study).
Identifiants
pubmed: 36648539
doi: 10.1007/s00402-023-04772-7
pii: 10.1007/s00402-023-04772-7
pmc: PMC10374828
doi:
Types de publication
Observational Study
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
4705-4711Informations de copyright
© 2023. The Author(s).
Références
Knee Surg Relat Res. 2020 Nov 23;32(1):63
pubmed: 33225974
Int Orthop. 2014 Apr;38(4):733-9
pubmed: 24162155
J Orthop Res. 2020 Jul;38(7):1472-1476
pubmed: 32293739
Orthopade. 2019 Nov;48(11):963-968
pubmed: 31506824
J Arthroplasty. 2015 Oct;30(10):1699-704
pubmed: 26021908
SICOT J. 2020;6:25
pubmed: 32618563
Am J Orthop (Belle Mead NJ). 2012 Nov;41(11):510-2
pubmed: 23431515
Knee Surg Sports Traumatol Arthrosc. 2021 Oct;29(10):3164-3169
pubmed: 32533222
J Am Acad Orthop Surg. 2016 Apr;24(4):220-30
pubmed: 26990712
J Knee Surg. 2020 Nov;33(11):1128-1131
pubmed: 31269525
J Arthroplasty. 2020 May;35(5):1239-1246.e1
pubmed: 31882347
Clin Orthop Relat Res. 2007 Nov;464:179-83
pubmed: 18062050
World J Orthop. 2013 Oct 18;4(4):287-90
pubmed: 24147264
Comput Aided Surg. 2012;17(2):96-101
pubmed: 22309295
J Arthroplasty. 2009 Feb;24(2):175-9
pubmed: 18534425
Knee. 2012 Aug;19(4):266-9
pubmed: 21561779
Knee Surg Sports Traumatol Arthrosc. 2014 Dec;22(12):2931-40
pubmed: 25026932
J Knee Surg. 2019 Jul;32(7):642-648
pubmed: 30068010
Orthopedics. 2010 Nov 02;33(11):797
pubmed: 21053892
Knee. 2016 Jan;23(1):149-51
pubmed: 26765862