His bundle combined with deep septal left bundle branch area pacing for atrial fibrillation prior to atrioventricular node ablation.

AV node ablation atrial fibrillation conduction system pacing his bundle pacing left bundle branch area pacing

Journal

Journal of arrhythmia
ISSN: 1880-4276
Titre abrégé: J Arrhythm
Pays: Japan
ID NLM: 101263026

Informations de publication

Date de publication:
Feb 2023
Historique:
received: 30 04 2022
revised: 17 11 2022
accepted: 25 11 2022
entrez: 3 2 2023
pubmed: 4 2 2023
medline: 4 2 2023
Statut: epublish

Résumé

To mitigate the risk of dyssynchrony-induced cardiomyopathy, international guidelines advocate His bundle pacing (HBP) with a ventricular backup lead prior to atrioventricular node ablation in treatment-refractory atrial fibrillation and normal left ventricular ejection fraction. As a result of concerns with long-term pacing parameters associated with HBP, this case series reports an adopted strategy of HBP combined with deep septal left bundle branch area pacing (dsLBBAP) in this patient cohort, enabling intrapatient comparison of the two pacing methods. Eight patients aged 72 ± 10 years (left ventricular ejection fraction 53 ± 4%) underwent successful combined HBP and dsLBBAP implant prior to AV node ablation. Intrinsic QRS duration was 118 ± 46 ms. When compared to dsLBBAP, HBP had lower sensed ventricular amplitude (2.4 ± 1.1 vs. 15 ± 5.3 V, Combined HBP and dsLBBAP pacing is a feasible approach as a pace and ablate strategy for atrial fibrillation refractory to medical therapy.

Sections du résumé

Background UNASSIGNED
To mitigate the risk of dyssynchrony-induced cardiomyopathy, international guidelines advocate His bundle pacing (HBP) with a ventricular backup lead prior to atrioventricular node ablation in treatment-refractory atrial fibrillation and normal left ventricular ejection fraction. As a result of concerns with long-term pacing parameters associated with HBP, this case series reports an adopted strategy of HBP combined with deep septal left bundle branch area pacing (dsLBBAP) in this patient cohort, enabling intrapatient comparison of the two pacing methods.
Methods and Results UNASSIGNED
Eight patients aged 72 ± 10 years (left ventricular ejection fraction 53 ± 4%) underwent successful combined HBP and dsLBBAP implant prior to AV node ablation. Intrinsic QRS duration was 118 ± 46 ms. When compared to dsLBBAP, HBP had lower sensed ventricular amplitude (2.4 ± 1.1 vs. 15 ± 5.3 V,
Conclusions UNASSIGNED
Combined HBP and dsLBBAP pacing is a feasible approach as a pace and ablate strategy for atrial fibrillation refractory to medical therapy.

Identifiants

pubmed: 36733330
doi: 10.1002/joa3.12800
pii: JOA312800
pmc: PMC9885312
doi:

Types de publication

Journal Article

Langues

eng

Pagination

27-33

Informations de copyright

© 2022 The Authors. Journal of Arrhythmia published by John Wiley & Sons Australia, Ltd on behalf of Japanese Heart Rhythm Society.

Déclaration de conflit d'intérêts

None to declare.

Références

Acta Cardiol. 2022 May;77(3):222-230
pubmed: 34078244
Europace. 2017 Dec 01;19(suppl_4):iv10-iv16
pubmed: 29220422
Pacing Clin Electrophysiol. 2021 Sep;44(9):1523-1531
pubmed: 34337768
J Am Coll Cardiol. 2018 May 22;71(20):2319-2330
pubmed: 29535066
Circ Cardiovasc Qual Outcomes. 2017 Jun;10(6):
pubmed: 28630373
J Cardiovasc Electrophysiol. 2016 Oct;27(10):1174-1179
pubmed: 27457998
J Cardiovasc Electrophysiol. 2020 Jan;31(1):286-292
pubmed: 31724791
Eur Heart J. 2021 Sep 14;42(35):3427-3520
pubmed: 34455430
Heart Vessels. 2016 Jul;31(7):1131-9
pubmed: 26142378
J Interv Card Electrophysiol. 2022 Jan;63(1):215-224
pubmed: 34173915
JACC Clin Electrophysiol. 2021 Nov;7(11):1422-1432
pubmed: 34167929
Heart Rhythm. 2019 Dec;16(12):1783-1790
pubmed: 31513945
Heart Rhythm. 2019 Dec;16(12):1774-1782
pubmed: 31136869
J Am Coll Cardiol. 2020 Feb 4;75(4):347-359
pubmed: 32000945
Eur Heart J. 2021 Dec 7;42(46):4731-4739
pubmed: 34453840
Heart Rhythm. 2018 Mar;15(3):460-468
pubmed: 29107697
Heart Lung Circ. 2020 Oct;29(10):1493-1501
pubmed: 32089490
Heart Rhythm. 2014 Sep;11(9):1619-25
pubmed: 24893122
Heart Rhythm. 2016 Dec;13(12):2272-2278
pubmed: 27855853

Auteurs

Michael C Y Nam (MCY)

Department of Cardiology Royal Melbourne Hospital Parkville Victoria Australia.

Patricia O'Sullivan (P)

Department of Cardiology Royal Melbourne Hospital Parkville Victoria Australia.

Ivaylo Tonchev (I)

Department of Cardiology Royal Melbourne Hospital Parkville Victoria Australia.

Benjamin M Moore (BM)

Department of Cardiology Royal Melbourne Hospital Parkville Victoria Australia.

Troy Watts (T)

Department of Cardiology Royal Melbourne Hospital Parkville Victoria Australia.

Gareth Wynn (G)

Department of Cardiology Royal Melbourne Hospital Parkville Victoria Australia.

Geoff Lee (G)

Department of Cardiology Royal Melbourne Hospital Parkville Victoria Australia.

Subodh Joshi (S)

Department of Cardiology Royal Melbourne Hospital Parkville Victoria Australia.

Irene Stevenson (I)

Department of Cardiology Royal Melbourne Hospital Parkville Victoria Australia.

Classifications MeSH