Catheter ablation of atrioventricular nodal reentrant tachycardia with an irrigated contact-force sensing radiofrequency ablation catheter.
atrioventricular nodal reentrant tachycardia
irrigated catheter
radiofrequency ablation
slow pathway modification
Journal
Journal of cardiovascular electrophysiology
ISSN: 1540-8167
Titre abrégé: J Cardiovasc Electrophysiol
Pays: United States
ID NLM: 9010756
Informations de publication
Date de publication:
04 2023
04 2023
Historique:
revised:
09
01
2023
received:
23
09
2022
accepted:
22
01
2023
medline:
13
4
2023
pubmed:
5
2
2023
entrez:
4
2
2023
Statut:
ppublish
Résumé
Radiofrequency ablation (RFA) slow pathway modification for catheter ablation of atrioventricular nodal reentrant tachycardia (AVNRT) is traditionally performed using a 4-mm nonirrigated (NI) RF ablation catheter. Slow pathway modification using irrigated, contact-force sensing (ICFS) RFA catheters has been described in case reports, but the outcomes have not been systematically evaluated. Acute procedural outcomes of 200 consecutive patients undergoing slow pathway modification for AVNRT were analyzed. A 3.5-mm ICFS RFA catheter (ThermoCool SmartTouch STSF, Biosense Webster, Inc.) was utilized in 134 patients, and a 4-mm NI RFA catheter (EZ Steer, Biosense Webster, Inc.) was utilized in 66 patients. Electroanatomic maps were retrospectively analyzed in a blinded fashion to determine the proximity of ablation lesions to the His region. The baseline characteristics of patients in both groups were similar. Total RF time was significantly lower in the ICFS group compared to the NI group (5.53 ± 4.6 vs. 6.24 ± 4.9 min, p = 0.03). Median procedure time was similar in both groups (ICFS, 108.0 (87.5-131.5) min vs. NI, 100.0 (85.0-125.0) min; p = 0.2). Ablation was required in closer proximity to the His region in the NI group compared to the ICFS group (14.4 ± 5.9 vs. 16.7 ± 6.4 mm, respectively, p = 0.01). AVNRT was rendered noninducible in all patients, and there was no arrhythmia recurrence during follow-up in both groups. Catheter ablation was complicated by AV block in one patient in the NI group. Slow pathway modification for catheter ablation of AVNRT using an ICFS RFA catheter is feasible, safe, and may facilitate shorter duration ablation while avoiding ablation in close proximity to the His region.
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
942-946Informations de copyright
© 2023 Wiley Periodicals LLC.
Références
Wittkampf FHM, Nakagawa H. RF catheter ablation: lessons on lesions. Pacing Clin Electrophysiol. 2006;29(11):1285-1297. doi:10.1111/j.1540-8159.2006.00533.x
Calkins H, Epstein A, Packer D, et al. Catheter ablation of ventricular tachycardia in patients with structural heart disease using cooled radiofrequency energy. J Am Coll Cardiol. 2000;35(7):1905-1914. doi:10.1016/s0735-1097(00)00615-x
Soejima K, Delacretaz E, Suzuki M, et al. Saline-cooled versus standard radiofrequency catheter ablation for infarct-related ventricular tachycardias. Circulation. 2001;103(14):1858-1862. doi:10.1161/01.cir.103.14.1858
Chrispin J, Misra S, Marine JE, et al. Current management and clinical outcomes for catheter ablation of atrioventricular nodal re-entrant tachycardia. EP Europace. 2018;20(4):e51-e59. doi:10.1093/europace/eux110
AlMahameed ST, Buxton AE, Michaud GF. New criteria during right ventricular pacing to determine the mechanism of supraventricular tachycardia. Circ Arrhythmia Electrophysiol. 2010;3(6):578-584. doi:10.1161/CIRCEP.109.931311
Bennett MT, Leong-Sit P, Gula LJ, et al. Entrainment for distinguishing atypical atrioventricular node reentrant tachycardia from atrioventricular reentrant tachycardia over septal accessory pathways with long-RP tachycardia. Circ Arrhythmia Electrophysiol. 2011;4(4):506-509. doi:10.1161/CIRCEP.111.961987
Bertini M, Brieda A, Balla C, et al. Efficacy and safety of catheter ablation of atrioventricular nodal re-entrant tachycardia by means of flexible-tip irrigated catheters. J Interv Card Electrophysiol. 2020;58(1):61-67. doi:10.1007/s10840-019-00578-z
Contino C, Weiss M, Riley M, Frisch D. Atrioventricular nodal reentrant tachycardia ablation with a power-controlled, contact-force catheter. J Innov Cardiac Rhythm Manag. 2020;11(11):4297-4300. doi:10.19102/icrm.2020.111103
Nath S, DiMarco JP, Haines DE. Basic aspects of radiofrequency catheter ablation. J Cardiovasc Electrophysiol. 1994;5(10):863-876. doi:10.1111/j.1540-8167.1994.tb01125.x