A dry chemistry-based electrochemiluminescence device for point-of-care testing of alanine transaminase.
Alanine transaminase detection
Automatic analyzer
Dry chemistry
Electrochemiluminescence
Point-of-care testing
Journal
Talanta
ISSN: 1873-3573
Titre abrégé: Talanta
Pays: Netherlands
ID NLM: 2984816R
Informations de publication
Date de publication:
01 May 2023
01 May 2023
Historique:
received:
19
11
2022
revised:
17
01
2023
accepted:
18
01
2023
pubmed:
5
2
2023
medline:
22
2
2023
entrez:
4
2
2023
Statut:
ppublish
Résumé
Liver disease causes serious public health problems because of its high prevalence, particularly affecting low- and middle-income countries. Alanine transaminase (ALT) is considered to be one of the most sensitive indicators for diagnosing liver disease. Although many strategies have been reported for ALT detection, few of them have solved the problem of automatic detection. In this work, for the first time, a dry chemistry-based electrochemiluminescence (DC-ECL) device is developed for point-of-care testing (POCT) of ALT, achieving real sample-to-answer detection. The proposed DC-ECL device consists of the following two components: (a) a DC-ECL chip consisting of the outer shell (including the top cap and pedestal) and detection layer (including the baseplate, electrode pad and carrier pad) and (b) an automatic ECL analyzer mainly including the data processing and instrument control unit, imaging detection unit, electrochemical reaction excitation unit, open detection window unit and rechargeable power supply. Under optimized conditions, the device had a wide detection range (0-1000 U/L), the ECL intensity linearly increased with ALT concentration (5-50 U/L) and logarithmic ALT concentration (50-1000 U/L), and the limit of detection was calculated to be 1.702 U/L. In addition, the DC-ECL device had the ability to measure ALT levels in human serum samples and showed acceptable selectivity, stability and repeatability. These results reveal that the DC-ECL device can overcome the disadvantages of traditional methods for ALT detection (such as high cost and requirement of professional technicians) and potentially opens the door to the development of similar POCT analyzers.
Identifiants
pubmed: 36738623
pii: S0039-9140(23)00038-3
doi: 10.1016/j.talanta.2023.124287
pii:
doi:
Substances chimiques
Alanine Transaminase
EC 2.6.1.2
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
124287Informations de copyright
Copyright © 2023 Elsevier B.V. All rights reserved.
Déclaration de conflit d'intérêts
Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.