Technique for Extraction and Revision of a Bent Intramedullary Nail for a Subtrochanteric Femur Fracture: A Case Report.
Journal
JBJS case connector
ISSN: 2160-3251
Titre abrégé: JBJS Case Connect
Pays: United States
ID NLM: 101596828
Informations de publication
Date de publication:
01 01 2023
01 01 2023
Historique:
entrez:
10
2
2023
pubmed:
11
2
2023
medline:
15
2
2023
Statut:
epublish
Résumé
A 17-year-old adolescent boy presented 2 months after initial intramedullary nail (IMN) fixation of a comminuted subtrochanteric fracture with refracture at the previous site and approximately 20° varus angulation of the nail. The bent femoral nail was successfully extracted using an open technique using Lohman bone-holding clamps and a broad plate. At the 1-year follow-up, fracture union was achieved. Removal of a deformed IMN is rare. No standardized protocol exists in guiding orthopaedic surgeons. A thorough review of techniques is discussed on this unusual complication.
Identifiants
pubmed: 36763704
doi: 10.2106/JBJS.CC.22.00453
pii: 01709767-202303000-00031
doi:
Types de publication
Case Reports
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Informations de copyright
Copyright © 2023 by The Journal of Bone and Joint Surgery, Incorporated.
Déclaration de conflit d'intérêts
Disclosure: The Disclosure of Potential Conflicts of Interest forms are provided with the online version of the article (http://links.lww.com/JBJSCC/B992).
Références
Marek D, Alan A. Femoral Shaft Fractures. NCBI Bookshelf. Tampa, FL, USA: StatPearls; 2022. https://www.ncbi.nlm.nih.gov/books/NBK556057/ . Accessed January 6,.
Paterno Mv, Archdeacon MT, Ford KR, Galvin D, Hewett TE. Early rehabilitation following surgical fixation of a femoral shaft fracture. Phys Ther. 2006;86(4):558-72.
Adnan RM, Zia MI, Amin J, Khan R, Ahmed S, Danish KF. Frequency of femoral fractures. Prof Med J. 2012;19(01):011-4.
Chokotho L, Wu HH, Shearer D, Lau BC, Mkandawire N, Gjertsen JE, Hallan G, Young S. Outcome at 1 year in patients with femoral shaft fractures treated with intramedullary nailing or skeletal traction in a low-income country: a prospective observational study of 187 patients in Malawi. Acta Orthopaedica. 2020;91(6):724-31.
Brumback RJ, Uwagie-Ero S, Lakatos RP, Poka A, Bathon GH, Burgess AR. Intramedullary nailing of femoral shaft fractures. Part II: JBJS. https://journals.lww.com/jbjsjournal/Abstract/1988/70100/Intramedullary_nailing_of_femoral_shaft_fractures_.3.aspx . Accessed January 11, 2022.
Ricci WM, Gallagher B, Haidukewych GJ. Intramedullary nailing of femoral shaft fractures: current concepts. J Am Acad Orthopaedic Surgeons. 2009;17(5):296-305.
Shen PC, Chen JC, Huang PJ, Lu CC, Tien YC, Cheng YM. A novel technique to remove bent intramedullary nail. J Trauma Inj Infect Crit Care. 2011;70(3):755-8.
Banerjee R, Posner M. Removal of a bent intramedullary nail with a posttraumatic sagittal plane deformity. J Trauma Inj Infect Crit Care. 2009;66(5):1500-3.
Patterson RH, Ramser JR. Technique for treatment of a bent Russell-Taylor femoral nail. J Orthop Trauma. 1991;5(4):506-8.
Canton G, Haxhaj B, Fattori R, Murena L. Bent femoral intramedullary nail: a case report and review of the literature. Acta Bio-Medica. 2019;90(1-S):187-91.
Kose O, Guler F, Kilicaslan OF, May H, Yuksel HY. Removal of a bent intramedullary nail in lower extremity: report of two cases and review of removal techniques. Arch Orthop Trauma Surg. 2016;136(2):195-202.
Nicolaides V, Polyzois V, Tzoutzopoulos A, Stavlas P, Grivas TB, Korres D. Bent femoral intramedullary nails: a report of two cases with need for urgent removal. Eur J Orthop Surg Traumatol. 2004;14(3):188-91.
Kritsaneephaiboon A, Tangtrakulwanich B, Maliwankul K. A novel minimally invasive technique for removal of a bent femoral intramedullary nail. Inj Extra. 2012;43(12):157-62.
Bek D, Demiralp B, Tunay S, Sehirlioglu A, Sabri Atesalp A. Removal of a bent inflatable femoral nail: a case report. Vol 42; 2008.10.3944/aott.2008.211
doi: 10.3944/aott.2008.211
Mahar AT, Lee SS, Lalonde FD, Impelluso T, Newton PO. Biomechanical comparison of stainless steel and titanium nails for fixation of simulated femoral fractures. J Pediatr Orthop. 2004;24(6):638-41.
Calafi LA, Antkowiak T, Curtiss S, Neu CP, Moehring D. A biomechanical comparison of the Surgical Implant Generation Network (SIGN) tibial nail with the standard hollow nail. Injury. 2010;41(7):753-7.
Biert J, Edwards MJR. Re: removal of a bent intramedullary nail with a posttraumatic sagittal plane deformity. J Trauma Inj Infect Crit Care. 2009;67(5):1132-3.
Suh YS, Lee WS, Ahn J, Choi HS, Baek MJ, Choi SW. Removal of bent intramedullary nail: two case reports. Medicine. 2020;99(20):e19935.
Apivatthakakul T, Chiewchantanakit S. Percutaneous removal of a bent intramedullary nail. Injury. 2001;32(9):725-6. www.elsevier.com/locate/injury .
Heffernan MJ, Leclair W, Li X. Use of the F-tool for the removal of a bent intramedullary femoral nail with a sagittal plane deformity. Orthopedics. 2012;35(3):e438-e441.
Nicholson P, Rice J, Curtin J. Management of a refracture of the femoral shaft with a bent intramedullary nail in situ. Injury. 1998;29(5):393-4.
Dhanda MS, Madan HS, Sharma SC, Ali N, Bhat A. Jumbo cutter for removal of a bent femoral interlocking nail: a cost effective method. J Clin Diagn Res. 2015;9(6):RD06-7.
Sakellariou VI, Kyriakopoulos S, Kotoulas H, Sofianos IP. Bent intramedullary femoral nail: surgical technique of removal and Reconstruction. Case Rep Orthopedics. 2011;2011:1-4.
Yang F, Tang J, Dai K, Huang Y. Metallic wear debris collected from patients induces apoptosis in rat primary osteoblasts via reactive oxygen species-mediated mitochondrial dysfunction and endoplasmic reticulum stress. Mol Med Rep. 2019;19(3):1629-37.
Linson MA, Scott R. Thermal burns associated with high-speed cortical drilling. Orthopedics. 1978;1(5):394-6.
Langton DJ, Joyce TJ, Jameson SS, Lord J, Van Orsouw M, Holland JP, Nargol AVF, De Smet KA. Adverse reaction to metal debris following hip resurfacing: the influence of component type, orientation and volumetric wear. J Bone Joint Surg Br Vol. 2011;93-B(2):164-71.
Mahendra G, Pandit H, Kliskey K, Murray D, Gill HS, Athanasou N. Necrotic and inflammatory changes in metal-on-metal resurfacing hip arthroplasties: relation to implant failure and pseudotumor formation. Acta Orthopaedica. 2009;80(6):653-9.