Portable sensing devices for smart healthcare and prevention of lead poisoning.


Journal

Journal of the Chinese Medical Association : JCMA
ISSN: 1728-7731
Titre abrégé: J Chin Med Assoc
Pays: Netherlands
ID NLM: 101174817

Informations de publication

Date de publication:
01 05 2023
Historique:
medline: 8 5 2023
pubmed: 18 2 2023
entrez: 17 2 2023
Statut: ppublish

Résumé

Lead (Pb) poisoning can damage human bodies silently, without specific symptoms or conspicuous warning signs. To provide safe and user-friendly tools for detecting heavy metals at low concentrations, scientists have developed and optimized versatile biosensors. To practically employ the developed biosensors specific for Pb (eg, the optimized Met-lead 1.44 M1), smartphone applications designed for user convenience and are easily operable for the on-site detection of Pb in environmental water, drinking water, food, and blood/urine are urgently needed. To establish a monitoring system for home health maintenance, a portable device and useful apps installed on a smartphone can be integrated, and the data acquired can be sent to and stored in the cloud for further analysis and evidence preservation. With the high transmissions speeds for 4G and 4G wireless Internet, such a system can be applied for health protection; water-quality data can be provided by anyone and publicly shared for display on smartphone interfaces, alerting individuals of heavy metal contamination. In this review, we describe recent developments in heavy metal-sensing devices, including home health maintenance systems, which have been successfully and practically applied to prevent heavy metal Pb poisoning.

Identifiants

pubmed: 36800256
doi: 10.1097/JCMA.0000000000000904
pii: 02118582-202305000-00003
doi:

Substances chimiques

Lead 2P299V784P
Metals, Heavy 0
Water 059QF0KO0R

Types de publication

Review Journal Article Research Support, Non-U.S. Gov't

Langues

eng

Sous-ensembles de citation

IM

Pagination

459-464

Informations de copyright

Copyright © 2023, the Chinese Medical Association.

Déclaration de conflit d'intérêts

Conflicts of interest: The authors declare that they have no conflicts of interest related to the subject matter or materials discussed in this article.

Références

Swaringen BF, Gawlik E, Kamenov GD, McTigue NE, Cornwell DA, Bonzongo JJ. Children’s exposure to environmental lead: a review of potential sources, blood levels, and methods used to reduce exposure. Environ Res. 2022;204(Pt B):112025.
Nriagu JO. A silent epidemic of environmental metal poisoning? Environ Pollut. 1988;50:139–61.
Neeleman H. Lead poisoning. Annu Rev Med. 2004;55:209–22.
Roy S, Edwards MA. Preventing another lead (Pb) in drinking water crisis: lessons from the Washington DC and Flint MI contamination events. Curr Opin Environ Sci Health. 2019;7:34–44.
Rees N, Fuller R. The toxic truth: children’s exposure to lead pollution undermines a generation of future potential. 2020. Available at https://www.unicef.org/reports/toxic-truth-childrens-exposure-to-lead-pollution-2020 . Accessed September 4, 2022.
Centers for Disease Control and Prevention (CDC). Blood lead levels in children. Available at https://www.cdc.gov/nceh/lead/prevention/blood-lead-levels.htm . Accessed October 25, 2022.
Ahamed M, Siddiqui MK. Low level lead exposure and oxidative stress: current opinions. Clin Chim Acta. 2007;383:57–64.
Rocha A, Trujillo KA. Neurotoxicity of low-level lead exposure: history, mechanisms of action, and behavioral effects in humans and preclinical models. Neurotoxicol. 2019;73:58–80.
Kim MG, Kim YW, Ahn YS. Does low lead exposure affect blood pressure and hypertension? J Occup Health. 2020;62:e12107.
Schütz A, Bergdahl IA, Ekholm A, Skerfving S. Measurement by ICP-MS of lead in plasma and whole blood of lead workers and controls. Occup Environ Med. 1996;53:736–40.
White WM, Albarède F, Télouk P. High-precision analysis of Pb isotope ratios by multi-collector ICP-MS. Chem Geol. 2000;167:257–70.
Zhang D, Liu Q. Biosensors and bioelectronics on smartphone for portable biochemical detection. Biosens Bioelectron. 2016;75:273–84.
Zhang Y, Sun J, Liu L, Qiao H. A review of biosensor technology and algorithms for glucose monitoring. J Diabe Complic. 2021;35:107929.
Liu A, Lang Q, Liang B, Shi J. Sensitive detection of maltose and glucose based on dual enzyme-displayed bacteria electrochemical biosensor. Biosens Bioelectron. 2017;87:25–30.
Bock A, Annibale P, Konrad C, Hannawacker A, Anton SE, Maiellaro I, et al. Optical mapping of cAMP signaling at the nanometer scale. Cell. 2020;182:1519–30.e17.
Ganesana M, Trikantzopoulos E, Maniar Y, Lee ST, Venton BJ. Development of a novel micro biosensor for in vivo monitoring of glutamate release in the brain. Biosens Bioelectron. 2019;130:103–9.
Li J, Liu Y, Yuan L, Zhang B, Bishop ES, Wang K, et al. A tissue-like neurotransmitter sensor for the brain and gut. Nature. 2022;606:94–101.
Lakard S, Pavel IA, Lakard B. Electrochemical biosensing of dopamine neurotransmitter: a review. Biosensors (Basel). 2021;11:179.
Muñoz-San Martín C, Pedrero M, Gamella M, Montero-Calle A, Barderas R, Campuzano S, et al. A novel peptide-based electrochemical biosensor for the determination of a metastasis-linked protease in pancreatic cancer cells. Anal Bioanal Chem. 2020;412:6177–88.
Huang H. Matrix metalloproteinase-9 (MMP-9) as a cancer biomarker and MMP-9 biosensors: recent advances. Sensors (Basel). 2018;18:3249.
Sin ML, Mach KE, Wong PK, Liao JC. Advances and challenges in biosensor-based diagnosis of infectious diseases. Expert Rev Mol Diagn. 2014;14:225–44.
Li P, Lee GH, Kim SY, Kwon SY, Kim HR, Park S. From diagnosis to treatment: recent advances in patient-friendly biosensors and implantable devices. ACS Nano. 2021;15:1960–2004.
Breslauer DN, Maamari RN, Switz NA, Lam WA, Fletcher DA. Mobile phone based clinical microscopy for global health applications. PLoS One. 2009;4:e6320.
Smith ZJ, Chu K, Espenson AR, Rahimzadeh M, Gryshuk A, Molinaro M, et al. Cell-phone-based platform for biomedical device development and education applications. PLoS One. 2011;6:e17150.
Agbana TE, Diehl JC, van Pul F, Khan SM, Patlan V, Verhaegen M, et al. Imaging & identification of malaria parasites using cellphone microscope with a ball lens. PLoS One. 2018;13:e0205020.
Wei Q, Qi H, Luo W, Tseng D, Ki SJ, Wan Z, et al. Fluorescent imaging of single nanoparticles and viruses on a smart phone. ACS Nano. 2013;7:9147–55.
Switz NA, D’Ambrosio MV, Fletcher DA. Low-cost mobile phone microscopy with a reversed mobile phone camera lens. PLoS One. 2014;9:e95330.
Wang LJ, Sun R, Vasile T, Chang YC, Li L. High-throughput optical sensing immunoassays on smartphone. Anal Chem. 2016;88:8302–8.
Wang LJ, Chang YC, Sun R, Li L. A multichannel smartphone optical biosensor for high-throughput point-of-care diagnostics. Biosens Bioelectron. 2017;87:686–92.
Knowlton S, Joshi A, Syrrist P, Coskun AF, Tasoglu S. 3D-printed smartphone-based point of care tool for fluorescence- and magnetophoresis-based cytometry. Lab Chip. 2017;17:2839–51.
Zhu H, Yaglidere O, Su TW, Tseng D, Ozcan A. Cost-effective and compact wide-field fluorescent imaging on a cell-phone. Lab Chip. 2011;11:315–22.
Zhu H, Mavandadi S, Coskun AF, Yaglidere O, Ozcan A. Optofluidic fluorescent imaging cytometry on a cell phone. Anal Chem. 2011;83:6641–7.
Wei Q, Nagi R, Sadeghi K, Feng S, Yan E, Ki SJ, et al. Detection and spatial mapping of mercury contamination in water samples using a smart-phone. ACS Nano. 2014;8:1121–9.
Shan Y, Wang B, Huang H, Jian D, Wu X, Xue L, et al. On-site quantitative Hg2+ measurements based on selective and sensitive fluorescence biosensor and miniaturized smartphone fluorescence microscope. Biosens Bioelectron. 2019;132:238–47.
Lai WQ, Chang YF, Chou FN, Yang DM. Portable FRET-based biosensor device for on-site lead detection. Biosensors (Basel). 2022;12:157.
Jain S, Nehra M, Kumar R, Dilbaghi N, Hu T, Kumar S, et al. Internet of medical things (IoMT)-integrated biosensors for point-of-care testing of infectious diseases. Biosens Bioelectron. 2021;179:113074.
Guo J, Chen S, Tian S, Liu K, Ni J, Zhao M, et al. 5G-enabled ultra-sensitive fluorescence sensor for proactive prognosis of COVID-19. Biosens Bioelectron. 2021;181:113160.
Nguyen H, Sung Y, O’Shaughnessy K, Shan X, Shih WC. Smartphone nanocolorimetry for on-demand lead detection and quantitation in drinking water. Anal Chem. 2018;90:11517–22.
Wang H, Yang L, Chu S, Liu B, Zhang Q, Zou L, et al. Semiquantitative visual detection of lead ions with a smartphone via a colorimetric paper-based analytical device. Anal Chem. 2019;91:9292–9.
Sajed S, Kolahdouz M, Sadeghi MA, Razavi SF. High-performance estimation of lead ion concentration using smartphone-based colorimetric analysis and a machine learning approach. ACS Omega. 2020;5:27675–84.
Liao J, Chang F, Han X, Ge C, Lin S. Wireless water quality monitoring and spatial mapping with disposable whole-copper electrochemical sensors and a smartphone. Sens Actu B Chem. 2020;306:127557.
Muhammad-Aree S, Teepoo S. On-site detection of heavy metals in wastewater using a single paper strip integrated with a smartphone. Anal Bioanal Chem. 2020;412:1395–405.
Xiao M, Liu Z, Xu N, Jiang L, Yang M, Yi C. A Smartphone-based sensing system for on-site quantitation of multiple heavy metal ions using fluorescent carbon nanodots-based microarrays. ACS Sens. 2020;5:870–8.
Srisukjaroen R, Kanokorn W, Siriwan T. A smartphone based-paper test strip chemosensor coupled with gold nanoparticles for the Pb2+ detection in highly contaminated meat samples. Microchemical J. 2022;179:107438.
Emmanuel N, Haridas R, Chelakkara S, Nair RB, Gopi A, Sajitha M, et al. Smartphone assisted colourimetric detection and quantification of Pb 2+ and Hg 2+ ions using ag nanoparticles from aqueous medium. IEEE Sens J. 2020;20:8512–9.
Chiu TY, Yang DM. Intracellular Pb2+ content monitoring using a protein-based Pb2+ indicator. Toxicol Sci. 2012;126:436–45.
Yang DM, Manurung RV, Lin YS, Chiu TY, Lai WQ, Chang YF, et al. Monitoring the heavy metal lead inside living drosophila with a FRET-based biosensor. Sensors (Basel). 2020;20:1712.
Yang DM, Fu TF, Lin CS, Chiu TY, Huang CC, Huang HY, et al. High-performance FRET biosensors for single-cell and in vivo lead detection. Biosens Bioelectron. 2020;168:112571.
Yang DM, Chang YF. Versatile cell and animal models for advanced investigation of lead poisoning. Biosensors (Basel). 2021;11:371.
Chiu TY, Chen PH, Chang CL, Yang DM. Live-cell dynamic sensing of Cd(2+) with a FRET-based indicator. PLoS One. 2013;8:e65853.

Auteurs

Wei-Qun Lai (WQ)

Microscopy Service Laboratory, Basic Research Division, Department of Medical Research, Taipei Veterans General Hospital, Taipei, Taiwan, ROC.
Institute of Biophotonics, School of Biomedical Science and Engineering, National Yang Ming Chiao Tung University, Taipei, Taiwan, ROC.

Ta-Chou Huang (TC)

Microscopy Service Laboratory, Basic Research Division, Department of Medical Research, Taipei Veterans General Hospital, Taipei, Taiwan, ROC.
Institute of Biophotonics, School of Biomedical Science and Engineering, National Yang Ming Chiao Tung University, Taipei, Taiwan, ROC.

Kung-Hao Liang (KH)

Laboratory of Systems Biomedical Science, Department of Medical Research, Taipei Veterans General Hospital, Taipei, Taiwan, ROC.
Institute of Food Safety and Health Risk Assessment, National Yang Ming Chiao Tung University, Taipei, Taiwan, ROC.

Yu-Fen Chang (YF)

LumiSTAR Biotechnology, Inc., Taipei, Taiwan, ROC.

De-Ming Yang (DM)

Microscopy Service Laboratory, Basic Research Division, Department of Medical Research, Taipei Veterans General Hospital, Taipei, Taiwan, ROC.
Institute of Biophotonics, School of Biomedical Science and Engineering, National Yang Ming Chiao Tung University, Taipei, Taiwan, ROC.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH