Ultrafast Spectral Tuning of a Fiber Laser for Time-Encoded Multiplex Coherent Raman Scattering Microscopy.


Journal

The journal of physical chemistry. B
ISSN: 1520-5207
Titre abrégé: J Phys Chem B
Pays: United States
ID NLM: 101157530

Informations de publication

Date de publication:
23 Mar 2023
Historique:
pubmed: 15 3 2023
medline: 15 3 2023
entrez: 14 3 2023
Statut: ppublish

Résumé

Coherent Raman scattering microscopy utilizing bioorthogonal tagging approaches like isotope or alkyne labeling allows for a targeted monitoring of spatial distribution and dynamics of small molecules of interest in cells, tissues, and other complex biological matrices. To fully exploit this approach in terms of real-time monitoring of several Raman tags, e.g., to study drug uptake dynamics, extremely fast tunable lasers are needed. Here, we present a laser concept without moving parts and fully electronically controlled for the quasi-simultaneous acquisition of coherent anti-Stokes Raman scattering images at multiple Raman resonances. The laser concept is based on the combination of a low noise and spectrally narrow Fourier domain mode-locked laser seeding a compact four wave mixing-based high-power fiber-based optical parametric amplifier.

Identifiants

pubmed: 36917762
doi: 10.1021/acs.jpcb.2c09115
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

2375-2380

Auteurs

Thomas Gottschall (T)

Friedrich-Schiller-Universität Jena, Institute of Applied Physics and Abbe Center of Photonics, Albert-Einstein-Str. 6, 07745 Jena, Germany.

Tobias Meyer-Zedler (T)

Institute of Physical Chemistry (IPC) and Abbe Center of Photonics (ACP), Friedrich Schiller University Jena, Member of the Leibniz Centre for Photonics in Infection Research (LPI), Helmholtzweg 4, 07743 Jena, Germany.
Leibniz Institute of Photonic Technology, Member of Leibniz Health Technologies, Member of the Leibniz Centre for Photonics in Infection Research (LPI), Albert-Einstein-Straße 9, 07745 Jena, Germany.

Matthias Eibl (M)

Institut für Biomedizinische Optik, Universität zu Lübeck, Peter-Monnik-Weg 4, 23562 Lübeck, Germany.

Tom Pfeiffer (T)

Institut für Biomedizinische Optik, Universität zu Lübeck, Peter-Monnik-Weg 4, 23562 Lübeck, Germany.

Hubertus Hakert (H)

Institut für Biomedizinische Optik, Universität zu Lübeck, Peter-Monnik-Weg 4, 23562 Lübeck, Germany.

Michael Schmitt (M)

Institute of Physical Chemistry (IPC) and Abbe Center of Photonics (ACP), Friedrich Schiller University Jena, Member of the Leibniz Centre for Photonics in Infection Research (LPI), Helmholtzweg 4, 07743 Jena, Germany.

Robert Huber (R)

Institut für Biomedizinische Optik, Universität zu Lübeck, Peter-Monnik-Weg 4, 23562 Lübeck, Germany.

Andreas Tünnermann (A)

Friedrich-Schiller-Universität Jena, Institute of Applied Physics and Abbe Center of Photonics, Albert-Einstein-Str. 6, 07745 Jena, Germany.
Fraunhofer Institute for Applied Optics and Precision Engineering, Albert-Einstein-Str. 7, 07745 Jena, Germany.

Jens Limpert (J)

Friedrich-Schiller-Universität Jena, Institute of Applied Physics and Abbe Center of Photonics, Albert-Einstein-Str. 6, 07745 Jena, Germany.
Fraunhofer Institute for Applied Optics and Precision Engineering, Albert-Einstein-Str. 7, 07745 Jena, Germany.

Juergen Popp (J)

Institute of Physical Chemistry (IPC) and Abbe Center of Photonics (ACP), Friedrich Schiller University Jena, Member of the Leibniz Centre for Photonics in Infection Research (LPI), Helmholtzweg 4, 07743 Jena, Germany.
Leibniz Institute of Photonic Technology, Member of Leibniz Health Technologies, Member of the Leibniz Centre for Photonics in Infection Research (LPI), Albert-Einstein-Straße 9, 07745 Jena, Germany.

Classifications MeSH