A study of balloon type on calcified coronary lesion predilation: A finite element analysis.


Journal

Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine
ISSN: 2041-3033
Titre abrégé: Proc Inst Mech Eng H
Pays: England
ID NLM: 8908934

Informations de publication

Date de publication:
Apr 2023
Historique:
medline: 4 4 2023
pubmed: 18 3 2023
entrez: 17 3 2023
Statut: ppublish

Résumé

Calcified coronary lesions have been one of the more difficult types of lesion for interventional treatment, and angioplasty is required to break the calcification before stent implantation so that the stent can expand smoothly, however, it remains unclear which type of angioplasty is optimal for different calcified lesions. In this study, a finite element approach was used to model normal balloons, cutting balloons, and AngioSculpt balloons. In addition, calcified lesions of different degrees, thicknesses, and lengths were modeled according to Intravascular ultrasound (IVUS) calcification grade. The above three balloons were used to pretreat calcified lesions, and the brittle fracture module for calcification was used to detect fracture success, to facilitate virtual stent implantation after predilation. The simulation results showed that with a thickness of less than 0.3 mm, balloons were unable to deal with calcified plaques in lesions of less than 120°, for 180° calcified lesions the cutting balloon fractured the calcified material at 1.2 MPa, the AngioSculpt balloon produced multiple fractures at 0.8 MPa for 270° calcified plaques, but was unable to fracture calcified lesions with a thickness of 0.4 mm. Based on these results, we conclude that the length of the lesion did not affect calcification fracture, while the thickness of the lesion did. In calcified lesions of approximately 180°, the cutting balloon showed the best predilation results, while the AngioSculpt balloon was optimal for 270°. In annular calcification, all three balloons were unable to fracture the lesion.

Identifiants

pubmed: 36927166
doi: 10.1177/09544119231157853
pmc: PMC10020853
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

443-450

Auteurs

Jiasong Li (J)

Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application, Beijing, China.

Hongshuai Cao (H)

Beijing Anzhen Hospital, Capital Medical University, Beijing, China.

Meng Li (M)

Beijing Anzhen Hospital, Capital Medical University, Beijing, China.

Lixia Shu (L)

Beijing Anzhen Hospital, Capital Medical University, Beijing, China.

Changyan Lin (C)

Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application, Beijing, China.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH