Surface Pressures in Lower Extremity Splints: A Biomechanical Study.

iatrogenic injury immobilization patient safety pressure wounds splints trauma

Journal

Foot & ankle orthopaedics
ISSN: 2473-0114
Titre abrégé: Foot Ankle Orthop
Pays: United States
ID NLM: 101752333

Informations de publication

Date de publication:
Jan 2023
Historique:
entrez: 20 3 2023
pubmed: 21 3 2023
medline: 21 3 2023
Statut: epublish

Résumé

Though ubiquitously used in orthopaedic trauma, lower extremity splints may have associated iatrogenic risk of morbidity. Although clinicians pad bony prominences to minimize skin pressure, the effect of joint position on skin pressure and, more specifically, changing joint position, is understudied. The purpose of this biomechanical study is to determine the effect of various short-leg splint application techniques on anterior ankle surface pressure in the development of iatrogenic skin pressure ulcers. Various constructs of lower extremity, short-leg splints were applied to 3 healthy subjects (6 limbs total) with an underlying pressure transducer (Tekscan I-Scan system) on the skin surface centered on the tibialis anterior tendon at the level of the ankle. All subjects underwent anterior ankle surface pressure assessment when padding was applied in maximum plantar flexion and neutral position for conventional short-leg splints application in clinically relevant patient scenarios. Percentage change from initial contact pressure centered on the tibialis anterior with cast padding were calculated. The percentage change in anterior ankle contact pressure when padding was applied in maximum plantar flexion (PF) and then definitively placed in neutral was increased at least 2-fold without the addition of plaster in lower extremity short-leg splints. Removing anterior ankle padding following final splint application in neutral reduced contact forces at the anterior ankle 46% and 59% in splints applied in maximum PF and neutral ankle position, respectively. The present study is the first of its kind to underscore and quantify clinically relevant technical pearls that can be useful in reducing risk of iatrogenic risk of skin breakdown at the anterior ankle when placing short-leg splints, mainly, that it is imperative to apply padding in the intended final splint position and to remove anterior ankle padding following splint application when able. Level IV, biomechanical study with clear hypothesis.

Sections du résumé

Background UNASSIGNED
Though ubiquitously used in orthopaedic trauma, lower extremity splints may have associated iatrogenic risk of morbidity. Although clinicians pad bony prominences to minimize skin pressure, the effect of joint position on skin pressure and, more specifically, changing joint position, is understudied. The purpose of this biomechanical study is to determine the effect of various short-leg splint application techniques on anterior ankle surface pressure in the development of iatrogenic skin pressure ulcers.
Methods UNASSIGNED
Various constructs of lower extremity, short-leg splints were applied to 3 healthy subjects (6 limbs total) with an underlying pressure transducer (Tekscan I-Scan system) on the skin surface centered on the tibialis anterior tendon at the level of the ankle. All subjects underwent anterior ankle surface pressure assessment when padding was applied in maximum plantar flexion and neutral position for conventional short-leg splints application in clinically relevant patient scenarios. Percentage change from initial contact pressure centered on the tibialis anterior with cast padding were calculated.
Results UNASSIGNED
The percentage change in anterior ankle contact pressure when padding was applied in maximum plantar flexion (PF) and then definitively placed in neutral was increased at least 2-fold without the addition of plaster in lower extremity short-leg splints. Removing anterior ankle padding following final splint application in neutral reduced contact forces at the anterior ankle 46% and 59% in splints applied in maximum PF and neutral ankle position, respectively.
Conclusion UNASSIGNED
The present study is the first of its kind to underscore and quantify clinically relevant technical pearls that can be useful in reducing risk of iatrogenic risk of skin breakdown at the anterior ankle when placing short-leg splints, mainly, that it is imperative to apply padding in the intended final splint position and to remove anterior ankle padding following splint application when able.
Level of Evidence UNASSIGNED
Level IV, biomechanical study with clear hypothesis.

Identifiants

pubmed: 36937805
doi: 10.1177/24730114231160115
pii: 10.1177_24730114231160115
pmc: PMC10014985
doi:

Types de publication

Journal Article

Langues

eng

Pagination

24730114231160115

Informations de copyright

© The Author(s) 2023.

Déclaration de conflit d'intérêts

The author(s) declared no potential conflicts of interest with respect to the research, authorship, and/or publication of this article. ICMJE forms for all authors are available online.

Références

Crit Care Nurse. 2013 Dec;33(6):57-66
pubmed: 24293556
Arch Plast Surg. 2012 Jul;39(4):412-6
pubmed: 22872847
J Am Acad Orthop Surg. 2008 Jan;16(1):30-40
pubmed: 18180390
Biomed Tech (Berl). 1993 Oct;38(10):243-8
pubmed: 8268402
J Am Acad Orthop Surg. 2010 Sep;18(9):568-75
pubmed: 20810938
J Pediatr Orthop. 2019 Feb;39(2):76-84
pubmed: 28060178
Nurs Clin North Am. 1987 Jun;22(2):359-77
pubmed: 3554149
Br J Nurs. 1998 Oct 8-21;7(18):1084, 1088-92, 1096 passim
pubmed: 9830918
JAMA. 2003 Jan 8;289(2):223-6
pubmed: 12517234
Indian J Plast Surg. 2012 May;45(2):244-54
pubmed: 23162223
Adv Skin Wound Care. 2015 Jun;28(6):267-73
pubmed: 25988736
Wound Repair Regen. 2008 Mar-Apr;16(2):151-68
pubmed: 18318801
Arthroscopy. 2017 Mar;33(3):617-624
pubmed: 27956232
Int Orthop. 2021 Jun;45(6):1567-1572
pubmed: 33877406
J Biomech. 2022 May;136:111074
pubmed: 35413514
Orthop J Sports Med. 2015 Aug 18;3(8):2325967115599347
pubmed: 26535390
J Bone Joint Surg Am. 1978 Jun;60(4):499-505
pubmed: 670272
Ther Clin Risk Manag. 2017 Feb 17;13:207-213
pubmed: 28255240

Auteurs

Kempland C Walley (KC)

Department of Orthopaedic Surgery, University of Michigan, Michigan Medicine, Ann Arbor, MI, USA.

Nicholas Farrar (N)

Department of Orthopaedic Surgery, University of Michigan, Michigan Medicine, Ann Arbor, MI, USA.

Kameron Shams (K)

Department of Orthopaedic Surgery, University of Michigan, Michigan Medicine, Ann Arbor, MI, USA.

Albert T Anastasio (AT)

Department of Orthopaedic Surgery, Duke University, Durham, NC, USA.

Davin Gong (D)

Department of Orthopaedic Surgery, University of Michigan, Michigan Medicine, Ann Arbor, MI, USA.

Kristopher Mell (K)

Department of Orthopaedic Surgery, University of Michigan, Michigan Medicine, Ann Arbor, MI, USA.

James R Holmes (JR)

Department of Orthopaedic Surgery, University of Michigan, Michigan Medicine, Ann Arbor, MI, USA.

David M Walton (DM)

Department of Orthopaedic Surgery, University of Michigan, Michigan Medicine, Ann Arbor, MI, USA.

Paul G Talusan (PG)

Department of Orthopaedic Surgery, University of Michigan, Michigan Medicine, Ann Arbor, MI, USA.

Classifications MeSH