Impact of the use of cusp-overlap projection on the incidence of permanent pacemaker implantation post-transcatheter aortic valve implantation with self-expanding valves.
Conduction disturbances
Cusp-overlap projection
Distúrbios de condução
Substituição valvar aórtica percutânea
Transcatheter aortic valve replacement
Técnica de sobreposição de cúspides
Journal
Revista portuguesa de cardiologia : orgao oficial da Sociedade Portuguesa de Cardiologia = Portuguese journal of cardiology : an official journal of the Portuguese Society of Cardiology
ISSN: 2174-2030
Titre abrégé: Rev Port Cardiol
Pays: Portugal
ID NLM: 8710716
Informations de publication
Date de publication:
09 2023
09 2023
Historique:
received:
05
07
2022
revised:
14
09
2022
accepted:
11
10
2022
medline:
5
9
2023
pubmed:
23
3
2023
entrez:
22
3
2023
Statut:
ppublish
Résumé
Current rates of permanent pacemaker implantation (PPMI) after transcatheter aortic valve implantation (TAVI) range between 3.4% and 25.9%. PPMI is associated with a worse prognosis. A lower valve implantation depth is associated with an increased risk of conduction disturbances. Theoretically, cusp-overlap projection (COP) has the potential to enable higher valve deployment. To compare the 30-day PPMI incidence post-TAVI using self-expanding valves according to the fluoroscopic guidance technique. This retrospective single-center study assessed consecutive patients undergoing TAVI with CoreValve™ valves between April 2019 and November 2021, grouped according to the fluoroscopic guidance technique (COP vs. coplanar implantation technique [CIT]). A total of 122 patients were included, predominantly women (52.5%), with a mean age of 81.6±5.5 years. COP was used in 49.2% of the sample. The CIT group had a significantly higher prevalence of previous beta-blocker use (p<0.01), lower baseline left ventricular ejection fraction (p=0.04) and a higher EuroSCORE II (p=0.02). The 30-day PPMI rate was 27.9% (n=34), with no significant difference between the COP and CIT groups (26.7% vs. 29.0%, p=0.77). Complete atrioventricular block was the main cause (38.5%). Likewise, mean fluoroscopy time (p=0.14) and contrast volume (p=0.35) used were similar between the two groups. Radiation dose was lower in the COP group (p=0.02). There was no significant difference between post-TAVI grades III and IV aortic valve regurgitation (p=0.27) and there were no cases of periprocedural acute coronary occlusion. This study shows that the COP technique, although safe and not associated with increased complexity, did not significantly reduce the 30-day PPMI rate compared to the traditional CIT view.
Identifiants
pubmed: 36948457
pii: S0870-2551(23)00166-X
doi: 10.1016/j.repc.2022.10.011
pii:
doi:
Types de publication
Journal Article
Langues
eng
por
Sous-ensembles de citation
IM
Pagination
759-769Commentaires et corrections
Type : CommentIn
Informations de copyright
Copyright © 2023 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.