Preloaded DMEK With Endothelium Outward: A Multicenter Clinical Study Using DMEK Rapid Device.


Journal

Cornea
ISSN: 1536-4798
Titre abrégé: Cornea
Pays: United States
ID NLM: 8216186

Informations de publication

Date de publication:
01 Jan 2024
Historique:
received: 31 10 2022
accepted: 08 02 2023
medline: 6 12 2023
pubmed: 25 3 2023
entrez: 24 3 2023
Statut: ppublish

Résumé

The objective of this study is to validate Descemet membrane endothelial keratoplasty (DMEK) Rapid device for preloading DMEK grafts with endothelium outward. In this multicenter retrospective clinical study, DMEK tissues (n = 27) were peeled and preloaded (8.25 mm) in a DMEK Rapid device. The device was loaded in a container prefilled with the storage solution and shipped from a single center in Italy to 4 different centers located in Italy and the United Kingdom. Preloaded tissues were delivered by injecting the graft in the anterior chamber. Patients were monitored at days 1 and 15 and at months 1, 3, and 6, as well as at the last follow-up (9-12 months) postoperatively. Main outcome measures included rebubbling rate and graft failure, corrected distance visual acuity, endothelial cell loss (ECL), and central corneal thickness at all time points. A one-way analysis of variance test comparing day 1 with all later time points was followed with significance at P < 0.05. The average recorded surgical time was 6 to 25 minutes with no immediate surgical complications. Rebubbling was observed in 7 of 26 cases with one graft failure within 15 days postoperatively. The mean corrected distance visual acuity at day 1 was 0.64 ± 0.49 logMAR, which improved to 0.18 ± 0.43 logMAR at the last follow-up. Endothelial cell density values showed a significant decrease at the last follow-up (1827 ± 565 cells/mm 2 ) ( P < 0.001) compared with the preoperative value (2503 ± 128 cells/mm 2 ), with an average endothelial cell loss of 27%. Central corneal thickness significantly dropped from 694 ± 157 μm at day 1 to 502 ± 42 μm at the last follow-up ( P < 0.001). DMEK Rapid device is quick, easy, and efficient for preloading and shipping DMEK grafts internationally in endothelium-outward orientation.

Identifiants

pubmed: 36961426
doi: 10.1097/ICO.0000000000003274
pii: 00003226-202401000-00007
doi:

Types de publication

Multicenter Study Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

38-44

Informations de copyright

Copyright © 2023 Wolters Kluwer Health, Inc. All rights reserved.

Déclaration de conflit d'intérêts

The authors declare no conflict of interest.

Références

Parekh M, Ruzza A, Steger B, et al. Cross-country transportation efficacy and clinical outcomes of preloaded large-diameter ultra-thin Descemet stripping automated endothelial keratoplasty grafts. Cornea 2019;38:30–34.
Melles GRJ, Ong TS, Ververs B, et al. Descemet membrane endothelial keratoplasty (DMEK). Cornea 2006;25:987–989.
Fernandez MM, Afshari NA. Endothelial keratoplasty: from DLEK to DMEK. Middle East Afr J Ophthalmol. 2010;17:5–8.
Romano V, Parekh M, Ruzza A, et al. Comparison of preservation and transportation protocols for preloaded Descemet membrane endothelial keratoplasty. Br J Ophthalmol. 2018;102:549–555.
Parekh M, Ruzza A, Romano V, et al. Descemet membrane endothelial keratoplasty learning curve for graft preparation in an eye bank using 645 donor corneas. Cornea 2018;37:767–771.
Ruzza A, Parekh M, Salvalaio G, et al. Bubble technique for Descemet membrane endothelial keratoplasty tissue preparation in an eye bank: air or liquid? Acta Ophthalmol. 2015;93:e129–e134.
Ang M, Wilkins MR, Mehta JS, et al. Descemet membrane endothelial keratoplasty. Br J Ophthalmol. 2016;100:15–21.
Parekh M, Ruzza A, Ferrari S, et al. Preloaded tissues for Descemet membrane endothelial keratoplasty. Am J Ophthalmol. 2016;166:120–125.
Busin M, Leon P, D'Angelo S, et al. Clinical outcomes of preloaded Descemet membrane endothelial keratoplasty grafts with endothelium tri-folded inwards. Am J Ophthalmol. 2018;193:106–113.
Parekh M, Pedrotti E, Viola P, et al. Factors affecting the success rate of preloaded Descemet membrane endothelial keratoplasty with endothelium-inward technique: a multicenter clinical study. Am J Ophthalmol. 2022;241:272–281.
Parekh M, Borroni D, Ruzza A, et al. A comparative study on different Descemet membrane endothelial keratoplasty graft preparation techniques. Acta Ophthalmol. 2018;96:e718–e726.
Ruzza A, Parekh M, Ferrari S, et al. Preloaded donor corneal lenticules in a new validated 3D printed smart storage glide for Descemet stripping automated endothelial keratoplasty. Br J Ophthalmol. 2015;99:1388–1395.
Feizi S. Corneal endothelial cell dysfunction: etiologies and management. Ther Adv Ophthalmol. 2018;10:5802.
Parekh M, Ruzza A, Ferrari S, et al. Endothelium-in versus endothelium-out for Descemet membrane endothelial keratoplasty graft preparation and implantation. Acta Ophthalmol. 2017;95:194–198.
Wojcik G, Parekh M, Romano V, et al. Preloaded Descemet membrane endothelial keratoplasty grafts with endothelium outward: a cross-country validation study of the DMEK rapid device. Cornea 2021;40:484–490.
Barnes K, Chiang E, Chen C, et al. Comparison of tri-folded and scroll-based graft viability in preloaded Descemet membrane endothelial keratoplasty. Cornea 2019;38:392–396.
Parekh M, Baruzzo M, Favaro E, et al. Standardizing Descemet membrane endothelial keratoplasty graft preparation method in the eye bank-experience of 527 Descemet membrane endothelial keratoplasty tissues. Cornea 2017;36:1458–1466.
Rickmann A, Wahl S, Hofmann N, et al. Comparison of preloaded grafts for Descemet membrane endothelial keratoplasty (DMEK) in a novel preloaded transport cartridge compared to conventional precut grafts. Cell Tissue Bank 2020;21:205–213.
Parekh M, Salvalaio G, Ruzza A, et al. Posterior lamellar graft preparation: a prospective review from an eye bank on current and future aspects. J Ophthalmol. 2013;2013:769860.
Parekh M, Romano V, Hassanin K, et al. Delivering endothelial keratoplasty grafts: modern day transplant devices. Curr Eye Res. 2022;47:493–504.
Parekh M, Romano D, Wongvisavavit R, et al. DMEK graft: one size does not fit all. Acta Ophthalmol. 2022;101:e14–e25.
Parekh M, Leon P, Ruzza A, et al. Graft detachment and rebubbling rate in Descemet membrane endothelial keratoplasty. Surv Ophthalmol. 2018;63:245–250.
Sahay P, Singhal D, Maharana PK, et al. Preloaded Descemet membrane endothelial keratoplasty donor tissue: surgical technique and early clinical results. Cornea 2018;38:981–986.
Potts LB, Bauer AJ, Xu DN, et al. The last 200 surgeon-loaded Descemet membrane endothelial keratoplasty tissue versus the first 200 preloaded Descemet membrane endothelial keratoplasty tissue. Cornea 2020;39:1261–1266.
Bohm MS, Wylegala A, Leon P, et al. One-year clinical outcomes of preloaded Descemet membrane endothelial keratoplasty versus non-preloaded Descemet membrane endothelial keratoplasty. Cornea 2021;40:311–319.
Romano V, Kazaili A, Pagano L, et al. Eye bank versus surgeon prepared DMEK tissues: influence on adhesion and re-bubbling rate. Br J Ophthalmol. 2022;106:177–183.
Romano V, Pagano L, Gadhvi KA, et al. Clinical outcomes of pre-loaded ultra-thin DSAEK and pre-loaded DMEK. BMJ Open Ophthalmol. 2020;5:e000546.
Leon P, Parekh M, Nahum Y, et al. Factors associated with early graft detachment in primary Descemet membrane endothelial keratoplasty. Am J Ophthalmol. 2018;187:117–124.
Agha B, Forster R, Kohnen T, et al. Influence of rebubbling on anterior segment parameters and refractive outcomes in eyes with DMEK for Fuchs endothelial dystrophy. Graefes Arch Clin Exp Ophthalmol. 2021;259:3175–3183.
Ademmer V, Agha B, Shajari M, et al. Impact of DMEK on visual quality in patients with Fuchs' endothelial dystrophy. Graefes Arch Clin Exp Ophthalmol. 2022;260:521–528.
Agha B, Ahmad N, Dawson DG, et al. Refractive outcome and tomographic changes after Descemet membrane endothelial keratoplasty in pseudophakic eyes with Fuchs' endothelial dystrophy. Int Ophthalmol. 2021;41:2897–2904.
Phylactou M, Matarazzo F, Din N, et al. Descemet membrane endothelial keratoplasty in vitrectomized eyes: a case series of outcomes and complications. Int Ophthalmol. 2021;41:2425–2432.
Bohm M, Leon P, Wylegala A, et al. Cost-effectiveness analysis of preloaded versus non-preloaded Descemet membrane endothelial keratoplasty for the treatment of Fuchs endothelial corneal dystrophy in an academic centre. Br J Ophthalmol. 2022;106:914–922.
Pagano L, Gadhvi KA, Parekh M, et al. Cost analysis of eye bank versus surgeon prepared endothelial grafts. BMC Health Serv Res. 2021;21:801.

Auteurs

Gabriela Wojcik (G)

International Centre for Ocular Physiopathology, Fondazione Banca degli Occhi del Veneto Onlus, Venice, Italy.

Mohit Parekh (M)

Department of Ophthalmology, Schepens Eye Research Institute of Massachusetts Eye and Ear, Harvard Medical School, Boston, MA.

Vito Romano (V)

Clinical Eye Research Centre, St Paul's Eye Unit, Royal Liverpool University Hospital, University of Liverpool, Liverpool, United Kingdom.
Department of Medical and Surgical Specialties, Radiological Sciences, and Public Health, Ophthalmology Clinic, University of Brescia, Italy.

Alessandro Ruzza (A)

International Centre for Ocular Physiopathology, Fondazione Banca degli Occhi del Veneto Onlus, Venice, Italy.

Vincenzo Scorcia (V)

Department of Medical and Surgical Sciences, Cornea and Ocular Surface Unit, Magna Graecia University of Catanzaro, Catanzaro, Italy.

Pietro Viola (P)

The Ophthalmology Operational Unit, Structural Department Specialist Surgery Vicenza, San Bortolo Hospital Vicenza, Vicenza, Italy; and.

Pia Leon (P)

International Centre for Ocular Physiopathology, Fondazione Banca degli Occhi del Veneto Onlus, Venice, Italy.
Department of Ophthalmology, Hospital SS. Giovanni e Paolo, Venice, Italy.

Antonella Franch (A)

Department of Ophthalmology, Hospital SS. Giovanni e Paolo, Venice, Italy.

Kunal A Gadhvi (KA)

Clinical Eye Research Centre, St Paul's Eye Unit, Royal Liverpool University Hospital, University of Liverpool, Liverpool, United Kingdom.

Diego Ponzin (D)

International Centre for Ocular Physiopathology, Fondazione Banca degli Occhi del Veneto Onlus, Venice, Italy.

Stefano Ferrari (S)

International Centre for Ocular Physiopathology, Fondazione Banca degli Occhi del Veneto Onlus, Venice, Italy.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH