Irrigating degradation properties of silk fibroin-collagen type II composite cartilage scaffold in vitro and in vivo.
Biocompatibility
Cartilage tissue engineering
Irrigating degradation
Mechanical property
Silk fibroin-collagen type II
Journal
Biomaterials advances
ISSN: 2772-9508
Titre abrégé: Biomater Adv
Pays: Netherlands
ID NLM: 9918383886206676
Informations de publication
Date de publication:
Jun 2023
Jun 2023
Historique:
received:
08
10
2022
revised:
07
03
2023
accepted:
13
03
2023
medline:
2
5
2023
pubmed:
26
3
2023
entrez:
25
3
2023
Statut:
ppublish
Résumé
Silk fibroin-collagen type II scaffolds are promising in cartilage tissue engineering due to their suitable biological functionality to promote proliferation of chondrocytes in vitro. However, their degradation properties, which are of crucial importance as scaffold degradation should consistent with the new tissue formation process, are still unknown. In this study, degradability of silk fibroin-collagen type II cartilage scaffolds was probed both in vitro and in vivo. In vitro degradation experiments show that the scaffolds decreased 32.25 % ± 0.62 %, 34.27 % ± 0.96 %, 36.27 % ± 2.39 % in weight after 8 weeks of degradation at the irrigation velocity of 0 mL/min, 7.89 mL/min and 15.79 mL/min. The degradation ratio, which increases with time and increasing irrigation velocity, is described by combining the built mathematic model and finite element modeling method. The scaffolds after 8 weeks of degradation in vitro keep their mechanical structural integrity to support new tissues. In vivo degradation experiments conducted in rabbits further show that the scaffolds degrade gradually, be absorbed with time and finally collapse in structure. The degradation process is accompanied by the growth of fibrous tissues and the scaffold is filled by fibrous tissues after 12 weeks of implantation. Immunohistology analysis shows that the inflammation caused by scaffolds is controllable and gradually alleviates with time. To sum up, silk fibroin-collagen type II cartilage scaffolds, which show suitable mechanical properties and biocompatibility during degradation in vitro and in vivo, have great potential in cartilage repair. The novelty of the study is that it not only introduces a mathematical model to predict the irrigation degradation ratio, but also provides experimental degradation data support for clinical application of silk fibroin-collagen type II cartilage scaffolds.
Identifiants
pubmed: 36965402
pii: S2772-9508(23)00112-7
doi: 10.1016/j.bioadv.2023.213389
pii:
doi:
Substances chimiques
Fibroins
9007-76-5
Collagen Type II
0
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
213389Informations de copyright
Copyright © 2023. Published by Elsevier B.V.
Déclaration de conflit d'intérêts
Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.