Test-retest reliability of high-resolution surface electromyographic activities of facial muscles during facial expressions in healthy adults: A prospective observational study.
electromyography
emotional expression
face
facial palsy
mimic muscles
reliability—reproducibility of results
Journal
Frontiers in human neuroscience
ISSN: 1662-5161
Titre abrégé: Front Hum Neurosci
Pays: Switzerland
ID NLM: 101477954
Informations de publication
Date de publication:
2023
2023
Historique:
received:
17
12
2022
accepted:
01
03
2023
medline:
31
3
2023
entrez:
30
3
2023
pubmed:
31
3
2023
Statut:
epublish
Résumé
Surface electromyography (sEMG) is a standard method for psycho-physiological research to evaluate emotional expressions or in a clinical setting to analyze facial muscle function. High-resolution sEMG shows the best results to discriminate between different facial expressions. Nevertheless, the test-retest reliability of high-resolution facial sEMG is not analyzed in detail yet, as good reliability is a necessary prerequisite for its repeated clinical application. Thirty-six healthy adult participants (53% female, 18-67 years) were included. Electromyograms were recorded from both sides of the face using an arrangement of electrodes oriented by the underlying topography of the facial muscles (Fridlund scheme) and simultaneously by a geometric and symmetrical arrangement on the face (Kuramoto scheme). In one session, participants performed three trials of a standard set of different facial expression tasks. On one day, two sessions were performed. The two sessions were repeated two weeks later. Intraclass correlation coefficient (ICC) and coefficient of variation statistics were used to analyze the intra-session, intra-day, and between-day reliability. Fridlund scheme, mean ICCs per electrode position: Intra-session: excellent (0.935-0.994), intra-day: moderate to good (0.674-0.881), between-day: poor to moderate (0.095-0.730). Mean ICC's per facial expression: Intra-session: excellent (0.933-0.991), intra-day: good to moderate (0.674-0.903), between-day: poor to moderate (0.385-0.679). Kuramoto scheme, mean ICC's per electrode position: Intra-session: excellent (0.957-0.970), intra-day: good (0.751-0.908), between-day: moderate (0.643-0.742). Mean ICC's per facial expression: Intra-session: excellent (0.927-0.991), intra-day: good to excellent (0.762-0.973), between-day: poor to good (0.235-0.868). The intra-session reliability of both schemes were equal. Compared to the Fridlund scheme, the ICCs for intra-day and between-day reliability were always better for the Kuramoto scheme. For repeated facial sEMG measurements of facial expressions, we recommend the Kuramoto scheme.
Identifiants
pubmed: 36992792
doi: 10.3389/fnhum.2023.1126336
pmc: PMC10040741
doi:
Types de publication
Journal Article
Langues
eng
Pagination
1126336Informations de copyright
Copyright © 2023 Trentzsch, Mueller, Heinrich, Kuttenreich, Guntinas-Lichius, Volk and Anders.
Déclaration de conflit d'intérêts
The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
Références
Laryngoscope. 2019 Oct;129(10):2274-2279
pubmed: 30570149
J Speech Hear Res. 1981 Jun;24(2):273-88
pubmed: 7265944
Int J Psychophysiol. 2011 Feb;79(2):330-3
pubmed: 21074582
PLoS One. 2021 Jul 19;16(7):e0254932
pubmed: 34280246
PLoS One. 2022 Feb 22;17(2):e0262286
pubmed: 35192638
Front Psychol. 2020 Jun 19;11:1388
pubmed: 32636788
Biol Psychol. 1991 Aug;31(1):73-93
pubmed: 2021681
Eur Arch Otorhinolaryngol. 2020 Jul;277(7):1855-1874
pubmed: 32270328
Psychol Sci Public Interest. 2019 Jul;20(1):1-68
pubmed: 31313636
Psychophysiology. 1986 Sep;23(5):567-89
pubmed: 3809364
Cranio. 2022 Nov 5;:1-10
pubmed: 36334278
Neurosci Biobehav Rev. 2014 Jan;38:135-59
pubmed: 24239732
Neuropsychopharmacol Rep. 2019 Sep;39(3):183-193
pubmed: 31136686
Psychophysiology. 2017 Jan;54(1):12-23
pubmed: 28000263
Sci Rep. 2018 Feb 1;8(1):2058
pubmed: 29391503
Psychophysiology. 1989 Jan;26(1):1-16
pubmed: 2922450
Front Hum Neurosci. 2022 Dec 12;16:1029415
pubmed: 36579128
J Chiropr Med. 2016 Jun;15(2):155-63
pubmed: 27330520
Facial Plast Surg. 2021 Oct;37(5):614-624
pubmed: 33682916
J Electromyogr Kinesiol. 2021 Feb;56:102485
pubmed: 33186835
Mov Disord. 2006 Nov;21(11):2015-8
pubmed: 16972238
Electromyogr Clin Neurophysiol. 1996 Mar;36(2):73-9
pubmed: 8925783
J Neurosci Methods. 2010 Mar 15;187(1):120-8
pubmed: 20064556
Front Physiol. 2018 May 17;9:566
pubmed: 29867587
Front Hum Neurosci. 2021 Jan 12;14:618985
pubmed: 33510628