Tolerance to Induced Astigmatism With a Monofocal Intraocular Lens Designed to Extend the Depth of Focus.
Journal
Journal of refractive surgery (Thorofare, N.J. : 1995)
ISSN: 1938-2391
Titre abrégé: J Refract Surg
Pays: United States
ID NLM: 9505927
Informations de publication
Date de publication:
Apr 2023
Apr 2023
Historique:
medline:
13
4
2023
entrez:
11
4
2023
pubmed:
12
4
2023
Statut:
ppublish
Résumé
To determine tolerance to residual astigmatism and visual performance in eyes implanted with a monofocal intraocular lens (IOL) designed to extend the depth of focus (Tecnis Eyhance, DIB00; Johnson & Johnson Vision) compared to eyes implanted with a standard monofocal IOL (Tecnis ZCB00; Johnson & Johnson Vision). This prospective, observational study enrolled consecutive patients who underwent routine cataract surgery and implantation of either the DIB00 (n = 20) or ZCB00 (n = 20) IOL. Astigmatic defocus was induced with a plus cylinder from +0.50 to +2.00 diopters (D) in 0.50-D steps for each astigmatic orientation (against-the-rule [ATR], with-the-rule [WTR], and oblique). Outcome measures included the comparison of mean visual acuity at each step of defocus, astigmatic defocus curves, and near and intermediate visual acuity. Eyes implanted with the DIB00 demonstrated greater astigmatic tolerance and were more likely to maintain 20/40 or better visual acuity with up to +2.00 D of induced ATR and oblique astigmatism than the ZCB00 IOLs. The DIB00 group showed 1.3 lines better visual acuity at 2.00 D of ATR astigmatic defocus and 1 line better than the ZCB00 group at 1.50 D of oblique astigmatic defocus. Although the distance visual acuity was comparable, near and intermediate visual acuities (both distance-corrected and uncorrected) were better for the DIB00 IOL than for the standard ZCB00 IOL. The monofocal IOL designed to extend the depth of focus (DIB00 group) showed greater tolerance to induced astigmatism in ATR and oblique orientations and superior uncorrected and distance-corrected near and intermediate visual acuity than the standard monofocal IOL of the same IOL platform.
Identifiants
pubmed: 37040207
doi: 10.3928/1081597X-20230126-02
doi:
Types de publication
Observational Study
Journal Article
Langues
eng
Sous-ensembles de citation
IM