Wearable and Stretchable SEBS/CB Polymer Conductive Strand as a Piezoresistive Strain Sensor.

SEBS/CB composite strand highly stretchable novel preparation technique piezoresistive sensor respiration activity strain posture detection wearable electronics

Journal

Polymers
ISSN: 2073-4360
Titre abrégé: Polymers (Basel)
Pays: Switzerland
ID NLM: 101545357

Informations de publication

Date de publication:
24 Mar 2023
Historique:
received: 11 01 2023
revised: 28 02 2023
accepted: 10 03 2023
medline: 14 4 2023
entrez: 13 4 2023
pubmed: 14 4 2023
Statut: epublish

Résumé

A wearable and stretchable strain sensor with a gauge factor above 23 was prepared using a simple and effective technique. Conducting nanocomposite strands were prepared from styrene-b-(ethylene-co-butylene)-b-styrene triblock copolymer (SEBS) and carbon black (CB) through a solvent-processing method that uses a syringe pump. This novel nanocomposite preparation technique is a straightforward and cost-effective process and is reported in the literature for the first time. The work included two stages: the flexible nanocomposite preparation stage and the piezoresistive sensor stage. Depending on its molecular structure, the thermoelastic polymer SEBS is highly resilient to stress and strain. The main aim of this work is to fabricate a highly flexible and piezoresistive nanocomposite fibre/strand. Among the prepared composites, a composite corresponding to a composition just above the percolation threshold was selected to prepare the strain sensor, which exhibited good flexibility and conductivity and a large piezoresistive effect that was linearly dependent on the applied strain. The prepared nanocomposite sensor was stitched onto a sports T-shirt. Commercially available knee and elbow sleeves were also purchased, and the nanocomposite SEBS/CB strands were sewn separately on the two sleeves. The results showed a high sensitivity of the sensing element in the case of breathing activity (normal breathing, a 35% change, and deep breathing at 135%, respectively). In the case of knee and elbow movements, simultaneous measurements were performed and found that the sensor was able to detect movement cycles during walking.

Identifiants

pubmed: 37050233
pii: polym15071618
doi: 10.3390/polym15071618
pmc: PMC10096618
pii:
doi:

Types de publication

Journal Article

Langues

eng

Subventions

Organisme : The Ministry of Education, Youth and Sports of the Czech Republic
ID : RP/CPS/2022/007).
Organisme : Internal grant agency of Tomas Bata University
ID : IGA/CPS/2020/008

Références

Mater Horiz. 2021 Aug 1;8(8):2123-2150
pubmed: 34846421
IEEE Trans Vis Comput Graph. 2022 Dec;28(12):4240-4251
pubmed: 34061744
ACS Nano. 2021 Jul 27;15(7):11555-11563
pubmed: 34128640
ACS Appl Mater Interfaces. 2019 Dec 11;11(49):46286-46295
pubmed: 31725262
Adv Mater. 2014 Aug 20;26(31):5310-36
pubmed: 24943999
J Neuroeng Rehabil. 2018 Sep 26;15(1):85
pubmed: 30253807
ACS Sens. 2020 Feb 28;5(2):481-489
pubmed: 32020796
Sci Rep. 2020 Aug 17;10(1):13867
pubmed: 32807827
Nanoscale. 2020 Oct 29;12(41):21447-21458
pubmed: 33084708
Adv Healthc Mater. 2017 Jun;6(11):
pubmed: 28371294
Front Physiol. 2017 Dec 11;8:922
pubmed: 29321742
ACS Appl Mater Interfaces. 2019 Jul 17;11(28):25034-25042
pubmed: 31268663
IEEE Trans Vis Comput Graph. 2020 Oct;26(10):3089-3108
pubmed: 31021797
ACS Omega. 2018 Oct 04;3(10):12648-12657
pubmed: 31457994
RSC Adv. 2020 Mar 18;10(19):11225-11232
pubmed: 35495339

Auteurs

Thaiskang Jamatia (T)

Centre of Polymer Systems, Tomas Bata University in Zlín, Tr. Tomase Bati 5678, 760 01 Zlin, Czech Republic.

Jiri Matyas (J)

Centre of Polymer Systems, Tomas Bata University in Zlín, Tr. Tomase Bati 5678, 760 01 Zlin, Czech Republic.

Robert Olejnik (R)

Centre of Polymer Systems, Tomas Bata University in Zlín, Tr. Tomase Bati 5678, 760 01 Zlin, Czech Republic.

Romana Danova (R)

Centre of Polymer Systems, Tomas Bata University in Zlín, Tr. Tomase Bati 5678, 760 01 Zlin, Czech Republic.

Jaroslav Maloch (J)

Centre of Polymer Systems, Tomas Bata University in Zlín, Tr. Tomase Bati 5678, 760 01 Zlin, Czech Republic.

David Skoda (D)

Centre of Polymer Systems, Tomas Bata University in Zlín, Tr. Tomase Bati 5678, 760 01 Zlin, Czech Republic.

Petr Slobodian (P)

Centre of Polymer Systems, Tomas Bata University in Zlín, Tr. Tomase Bati 5678, 760 01 Zlin, Czech Republic.
Department of Physics and Materials Engineering, Faculty of Technology, Tomas Bata University in Zlín, Vavrečkova 5669, 760 01 Zlin, Czech Republic.

Ivo Kuritka (I)

Centre of Polymer Systems, Tomas Bata University in Zlín, Tr. Tomase Bati 5678, 760 01 Zlin, Czech Republic.
Department of Chemistry, Faculty of Technology, Tomas Bata University in Zlín, Vavrečkova 5669, 760 01 Zlin, Czech Republic.

Classifications MeSH