Retention force, translucency, and microstructural properties of translucent temporary luting cements: An in vitro study.
Dental cements
Luting agents
Provisional luting materials
Pull-out force
Resin-based composite
Zinc oxide cement
Journal
Journal of the mechanical behavior of biomedical materials
ISSN: 1878-0180
Titre abrégé: J Mech Behav Biomed Mater
Pays: Netherlands
ID NLM: 101322406
Informations de publication
Date de publication:
06 2023
06 2023
Historique:
received:
25
01
2023
revised:
09
03
2023
accepted:
12
03
2023
medline:
12
5
2023
pubmed:
17
4
2023
entrez:
16
4
2023
Statut:
ppublish
Résumé
The aim of the study was to investigate the retention behaviour (pull-off force include adhesive remnant index = ARI) as well as translucency of various temporary luting cements and use microstructure elucidation methods to formulate explanatory approaches to their mode of action. The retention force of the temporary luting cements Provicol QM Plus (P+), Provicol QM Aesthetic (Pae), Bifix Temp (BiT), and as a reference a glass ionomer cement Meron (M) with a direct (Structur 3/S3) or an indirect (Structure CAD/SCAD) resin-based composite restauration was investigated after accelerated aging (thermocycling). Additional investigation of the physical properties was performed regarding to translucency and surface free energy. The microstructure was evaluated by X-ray diffraction, thermogravimetric analysis, differential scanning calorimetry and micro X-ray computed tomography. All tested temporary luting cements showed different pull-off forces in the range between 3.0 and 16.8 N in combination with S3 or SCAD after thermocycling. Only BiT with S3 showed pull-off forces of 129.2 N and complete retention on the restoration (ARI = 0), which was significant (p < .001) to all other samples. High translucency (BiT > Pae > M > P+) was observed for materials with lower crystalline content and low residual mass (usally resulting from higher organic content). M showed the highest surface free energy with a predominantly polar fraction, while BiT had a predominantly dispersive fraction. The highest porosity was observed in the coronal region of the restoration. The results suggest that translucency of temporary luting cements can be increased with higher organic and lower cryristall content. All combinations of cements and temporary restorations (direct/indirect; with the exception of BiT/S3) showed pull-off forces below 17 N (equivalent to a weight force of ∼1.7 kg), which allows manual detachment of the restoration by the dentist.
Identifiants
pubmed: 37062100
pii: S1751-6161(23)00134-0
doi: 10.1016/j.jmbbm.2023.105781
pii:
doi:
Substances chimiques
Resin Cements
0
Glass Ionomer Cements
0
Dental Cements
0
Types de publication
Journal Article
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Pagination
105781Informations de copyright
Copyright © 2023 Elsevier Ltd. All rights reserved.
Déclaration de conflit d'intérêts
Declaration of competing interest The authors declare the following financial interests/personal relationships which may be considered as potential competing interests: Andreas Koenig reports financial support was provided by VOCO GmbH.