"Koehlers teardrop is not a reliable landmark for assessing the centre of rotation after Total hip arthroplasty" - a retrospective radiological study.


Journal

Archives of orthopaedic and trauma surgery
ISSN: 1434-3916
Titre abrégé: Arch Orthop Trauma Surg
Pays: Germany
ID NLM: 9011043

Informations de publication

Date de publication:
Sep 2023
Historique:
received: 11 11 2022
accepted: 25 03 2023
medline: 28 8 2023
pubmed: 26 4 2023
entrez: 26 4 2023
Statut: ppublish

Résumé

Various anatomical landmarks have become established in radiography for the assessment of cup positioning after total hip arthroplasty (THA). The most important one is Koehler's teardrop figure (KTF). However, there is a lack of data on the validity of this landmark, which is widely used clinically for assessing the centre of rotation of the hip. A retrospective measurement of the lateral and cranial distance of the KTF to the centre of hip rotation was performed on the basis of 250 X-ray images of patients who had undergone THA. In addition, the dependence of these distances on pelvic tilt was determined in 16 patients by means of virtual X-ray projections based on pelvic CTs. It was shown that the distance of the KTF from the centre of hip rotation in the horizontal plane is gender-dependent (men: 42.8 ± 6.0 mm vs. women: 37.4 ± 4.7 mm; p < 0.001) and age-dependent (Pearson correlation  - 0.114; p < 0.05). Furthermore, the vertical and horizontal distances are subject to variation depending on height (Pearson correlation 0.14; p < 0.05 and 0.40; p < 0.001, respectively) and weight (Pearson correlation 0.158; p < 0.05). The distance between the KTF and the centre of hip rotation varies slightly depending on pelvic tilt. The KTF is not a sufficiently valid landmark for assessing the centre of rotation after THA. It is influenced by many different disturbance variables. However, it is largely robust against changes in pelvic tilt, so that it can be used as a reference point when comparing different intraindividual radiographs to assess the change in the centre of rotation due to implantation or to detect cup migration.

Identifiants

pubmed: 37099164
doi: 10.1007/s00402-023-04859-1
pii: 10.1007/s00402-023-04859-1
pmc: PMC10449955
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

5671-5676

Informations de copyright

© 2023. The Author(s).

Références

Ferguson RJ, Palmer AJ, Taylor A, Porter ML, Malchau H, Glyn-Jones S (2018) Hip replacement. Lancet 392:1662–1671
pubmed: 30496081 doi: 10.1016/S0140-6736(18)31777-X
Sathappan SS, Teicher ML, Capeci C, Yoon M, Wasserman BR, Jaffe WL (2007) Clinical outcome of Total hip arthroplasty using the normalized and Proportionalized femoral stem with a minimum 20-year follow-up. J Arthroplasty 22:356–362
pubmed: 17400091 doi: 10.1016/j.arth.2006.04.004
Havelin LI, Engesæter LB, Espehaug B, Furnes O, Lie SA, Vollset SE (2000) The Norwegian arthroplasty register: 11 years and 73,000 arthroplasties. Acta Orthop Scand 71:337–353
pubmed: 11028881 doi: 10.1080/000164700317393321
Sutherland CJ, Bresina SJ (1992) Measurement of acetabular component migration using two-dimensional radiography. J Arthroplasty 7:377–379
pubmed: 1431919 doi: 10.1016/S0883-5403(07)80027-1
Charles MN, Bourne RB, Davey JR, Greenwald AS, Morrey BF, Rorabeck CH (2004) Softtissue balancing of the hip: the role of femoral offset restoration. J Bone Joint Surg Am 86(5):1078–1088
doi: 10.2106/00004623-200405000-00030
Lecerf G, Fessy MH, Philippot R et al (2009) Femoral offset: anatomical concept, definition, assessment, implications for preoperative templating and hip arthroplasty. Orthop Traumatol Surg Res 95(3):210–219
pubmed: 19423418 doi: 10.1016/j.otsr.2009.03.010
Yoder SA, Brand RA, Pedersen DR, O’Gorman TW (1988) Total hip acetabular component position affects component loosening rates. Clin Orthop 228:79–87
doi: 10.1097/00003086-198803000-00012
Dihlmann SW, Ochsner PE, Pfister A, Mayrhofer P (1994) Analysis of migration of screwed acetabular components following revision arthroplasty of the hip joint. Results of single-image roentgen analysis. Z Orthop Ihre Grenzgeb 132(4):286–294
pubmed: 7941687 doi: 10.1055/s-2008-1039976
Goodman SB, Adler SJ, Fyhrie DP, Schurman DJ (1988) The acetabular teardrop and its relevance to acetabular migration. Clin Orthop 236:199–204
doi: 10.1097/00003086-198811000-00026
Callaghan JJ, Salvati EA, Pellicci PM, Wilson PD Jr, Ranawat CS (1985) Results of revision for mechanical failure after cemented total hip replacement, 1979 to 1982. A two to five-year follow-up. J Bone Joint Surg Am 67:1074–1085
pubmed: 4030826 doi: 10.2106/00004623-198567070-00011
Fessy MH, N’Diaye A, Carret JP, Fischer LP (1999) Locating the center of rotation of the hip. Surg Radiol Anat 21:247–250
pubmed: 10549080 doi: 10.1007/BF01631394
Kilicoglu OI, Turker M, Akgul T, Yazicioglu O (2013) Cementless total hip arthroplasty with modified oblique femoral shortening osteotomy in Crowe type IV congenital hip dislocation. J Arthroplast 28(1):117–125
doi: 10.1016/j.arth.2012.06.014
Erdemli B, Yilmaz C, Atalar H, Guzel B, Cetin I (2005) Total hip arthroplasty in developmental high dislocation of the hip. J Arthroplast 20(8):1021–1028
doi: 10.1016/j.arth.2005.02.003
Muratli KS, Karatosun V, Uzun B, Celik S (2014) Subtrochanteric shortening in total hip arthroplasty: biomechanical comparison of four techniques. J Arthroplast 29(4):836–842
doi: 10.1016/j.arth.2013.09.004
Köhler (1935) Roentgenology. The borderlands of the normal and early pathological in the Skiagram. London: Bailliere, Tindall, and Cox. 214- 222
Gates HS III, Coletti SC, Callaghan JJ, McCollum DE (1989) Radiographic measurements in protrusio acetabuli. J Arthroplasty 4(4):347–351
pubmed: 2621467 doi: 10.1016/S0883-5403(89)80036-1
Hamilton HW (1986) Prosthetic position in total hip replacement. Orthop Rev 15(5):294–300
pubmed: 3453937
Nagasawa F, Miyake Y, Akazawa H, Konishi Y, Uchida K, Mitani S, Inoue H (2000) Predictability of the progress of secondary osteoarthritis after developmental dislocation of the hip, utilizing inferior edge (of the teardrop)–center (of the femoral head) distance. J Orthop Sci 1:10–17
doi: 10.1007/s007760050003
Pierchon F, Migaud H, Duquennoy A, Fontaine C (1993) Radiologic evaluation of the rotation center of the hip. Rev Chir Orthop Reparatrice Appar Mot 7(4):281–284
Russotti GM, Harris WH (1991) Proximal placement of the acetabular component in total hip arthroplasty A long-term follow-up study. J Bone Joint Surg Am 73(4):587–592
pubmed: 2013598 doi: 10.2106/00004623-199173040-00016
Massin P, Schmidt L, Engh CA (1989) Evaluation of cementless acetabular component migration. An experimental study. J Arthroplasty 4(3):245–251
pubmed: 2795031 doi: 10.1016/S0883-5403(89)80020-8
Maratt JD, Esposito CI, McLawhorn AS, Jerabek SA, Padgett DE, Mayman DJ (2014) Pelvic tilt in patients undergoing total hip arthroplasty: when does it matter? J Arthroplasty 30:387–391
pubmed: 25453626 pmcid: 4359644 doi: 10.1016/j.arth.2014.10.014
Meftah M, Yadav A, Wong AC, Ranawat AS, Ranawa CSt, (2013) A novel method for accurate and reproducible functional cup positioning in total hip arthroplasty. J Arthroplasty 28(7):1200–1205
pubmed: 23462497 doi: 10.1016/j.arth.2012.09.018
Stephens A, Munir S, Shah S, Walter WL (2014) The kinematic relationship between sitting and standing posture and pelvic inclination and its significance to cup positioning in total hip arthroplasty. Int Orthop 39:383–388
pubmed: 25132150 doi: 10.1007/s00264-014-2491-y
Zhu J, Wan Z, Dorr LD (2010) Quantification of pelvic tilt in total hip arthroplasty. Clin Orthop Relat Res 468(2):571–575
pubmed: 19714387 doi: 10.1007/s11999-009-1064-7
Moskal JT, Capps SG (2010) Improving the accuracy of acetabular component orientation: avoiding malposition. J Am Acad Orthop Surg 18(5):286–296
pubmed: 20435879 doi: 10.5435/00124635-201005000-00005
Diehl P, Haenle M, Bergschmidt P, Gollwitzer H, Schauwecker J, Bader JR, Mittelmeier W (2010) Cementless total hip arthroplasty: a review. Biomed Tech (Berl) 55(5):251–264
pubmed: 20958235 doi: 10.1515/bmt.2010.037
Wohlrab D, Radetzki F, Noser H, Mendel T (2012) Cup positioning in total hip arthoplasty: spatial alignment of the acetabular entry plane. Arch Orthop Trauma Surg 132(1):1–7
pubmed: 21874577 doi: 10.1007/s00402-011-1379-1
Nunn D, Freeman MA, Hill PF, Evans SJ (1989) The measurement of migration of the acetabular component of hip prostheses. J Bone Joint Surg Br 71(4):629–631
pubmed: 2768311 doi: 10.1302/0301-620X.71B4.2768311
John JF, Fisher PE (1994) Radiographic determination of the anatomic hip joint center. A cadaver study. Acta Orthop Scand 65(5):509–510
pubmed: 7801750 doi: 10.3109/17453679409000901
Bowerman JW, Sena JM, Chang R (1982) The teardrop shadow of the pelvis; anatomy and clinical significance. Radiology 143(3):659–662
pubmed: 7079492 doi: 10.1148/radiology.143.3.7079492
O’Sullivan GS, Goodman SB, Jones HH (1992) Computerized tomographic evaluation of acetabular anatomy. Clin Orthop 277:175–181
doi: 10.1097/00003086-199204000-00021
Legaye J (2009) Influence of the sagittal balance of the spine on the anterior pelvic plane and on the acetabular orientation. Int Orthop 33(6):1695–1700
pubmed: 19148643 pmcid: 2899171 doi: 10.1007/s00264-008-0702-0
Pullen WM, Henebry A, Gaskill T (2014) Variability of acetabular coverage between supine and weightbearing pelvic radiographs. Am J Sports Med 42(11):2643–2648
pubmed: 25214530 doi: 10.1177/0363546514548854
Shon WY, Sharma V, Keon OJ, Moon JG, Suh DH (2014) Can pelvic tilting be ignored in total hip arthroplasty? Int J Surg Case Rep 5(9):633–636
pubmed: 25128730 pmcid: 4201023 doi: 10.1016/j.ijscr.2014.07.015
Ross JR, Nepple JJ, Philippon MJ, Kelly BT, Larson CM, Bedi A (2014) Effect of changes in pelvic tilt on range of motion to impingement and radiographic parameters of acetabular morphologic characteristics. Am J Sports Med 42(10):2402–2409
pubmed: 25060073 doi: 10.1177/0363546514541229
Babisch JW, Layher F, Amiot LP (2008) The rationale for tilt-adjusted acetabular cup navigation. J Bone Joint Surg Am 90(2):357–365
pubmed: 18245596 doi: 10.2106/JBJS.F.00628
Eilander W, Harris SJ, Henkus HE, Cobb JP, Hogervorst T (2013) Functional acetabular component position with supine total hip replacement. Bone Joint J 95B(10):1326–1331
doi: 10.1302/0301-620X.95B10.31446
Mayr E, Kessler O, Prassl A, Rachbauer F, Krismer M, Nogler M (2005) The frontal pelvic plane provides a valid reference system for implantation of the acetabular cup: spatial orientation of the pelvis in different positions. Acta Orthop 76(6):848–853
pubmed: 16470440 doi: 10.1080/17453670510045471
Preininger B, Haschke F, Perka C (2014) Diagnostics and therapy of luxation after total hip arthroplasty. Orthopade 43(1):54–63
pubmed: 24384890 doi: 10.1007/s00132-013-2125-x
Eggli S, Pisan M, Muller ME (1998) The value of preoperative planning for total hip arthroplasty. J Bone Joint Surg Br 80(3):382–390
pubmed: 9619923 doi: 10.1302/0301-620X.80B3.0800382
Ranawat CS, Dorr LD, Inglis AE (1980) Total hip arthroplasty in protrusion acetabuli of rheumatoid arthritis. J Bone Joint Surg Am 62(7):1059–1065
pubmed: 7430191 doi: 10.2106/00004623-198062070-00002

Auteurs

Kristian Heinz (K)

Orthopaedic Department, Jena Universitiy Hospital, Campus Eisenberg, Klosterlausnitzer Straße 81, 07607, Eisenberg, Germany. k.heinz@waldkliniken-eisenberg.de.

Dimitri Nowack (D)

Orthopaedic Department, Jena Universitiy Hospital, Campus Eisenberg, Klosterlausnitzer Straße 81, 07607, Eisenberg, Germany.

Rüdiger von Eisenhart-Rothe (R)

Orthopaedic Department, Klinikum Rechts Der Isar, Munich Universitiy, Munich, Germany.

Georgi Wassilew (G)

Orthopaedic Department, Greifswald Universitiy, Greifswald, Germany.

Georg Matziolis (G)

Orthopaedic Department, Jena Universitiy Hospital, Campus Eisenberg, Klosterlausnitzer Straße 81, 07607, Eisenberg, Germany.

Steffen Brodt (S)

Orthopaedic Department, Jena Universitiy Hospital, Campus Eisenberg, Klosterlausnitzer Straße 81, 07607, Eisenberg, Germany.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH