Deep learning-based reconstruction and 3D hybrid profile order technique for MRCP at 3T: evaluation of image quality and acquisition time.


Journal

European radiology
ISSN: 1432-1084
Titre abrégé: Eur Radiol
Pays: Germany
ID NLM: 9114774

Informations de publication

Date de publication:
Nov 2023
Historique:
received: 02 10 2022
accepted: 20 03 2023
revised: 06 03 2023
medline: 27 10 2023
pubmed: 14 5 2023
entrez: 13 5 2023
Statut: ppublish

Résumé

To evaluate the image quality of the 3D hybrid profile order technique and deep-learning-based reconstruction (DLR) for 3D magnetic resonance cholangiopancreatography (MRCP) within a single breath-hold (BH) at 3 T magnetic resonance imaging (MRI). This retrospective study included 32 patients with biliary and pancreatic disorders. BH images were reconstructed with and without DLR. The signal-to-noise ratio (SNR), contrast, contrast-to-noise ratio (CNR) between the common bile duct (CBD) and periductal tissues, and full width at half maximum (FWHM) of CBD on 3D-MRCP were evaluated quantitatively. Two radiologists scored image noise, contrast, artifacts, blur, and overall image quality of the three image types using a 4-point scale. Quantitative and qualitative scores were compared using the Friedman test and post hoc Nemenyi test. The SNR and CNR were not significantly different when under respiratory gating- and BH-MRCP without DLR. However, they were significantly higher under BH with DLR than under respiratory gating (SNR, p = 0.013; CNR, p = 0.027). The contrast and FWHM of MRCP under BH with and without DLR were lower than those under respiratory gating (contrast, p < 0.001; FWHM, p = 0.015). Qualitative scores for noise, blur, and overall image quality were higher under BH with DLR than those under respiratory gating (blur, p = 0.003; overall, p = 0.008). The combination of the 3D hybrid profile order technique and DLR is useful for MRCP within a single BH and does not lead to the deterioration of image quality and space resolution at 3 T MRI. Considering its advantages, this sequence might become the standard protocol for MRCP in clinical practice, at least at 3.0 T. • The 3D hybrid profile order can achieve MRCP within a single breath-hold without a decrease in spatial resolution. • The DLR significantly improved the CNR and SNR of BH-MRCP. • The 3D hybrid profile order technique with DLR reduces the deterioration of image quality in MRCP within a single breath-hold.

Identifiants

pubmed: 37178197
doi: 10.1007/s00330-023-09703-z
pii: 10.1007/s00330-023-09703-z
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

7585-7594

Informations de copyright

© 2023. The Author(s), under exclusive licence to European Society of Radiology.

Références

Taylor AC, Little AF, Hennessy OF, Banting SW, Smith PJ, Desmond PV (2002) Prospective assessment of magnetic resonance cholangiopancreatography for noninvasive imaging of the biliary tree. Gastrointest Endosc 55:17–22
doi: 10.1067/mge.2002.120324 pubmed: 11756908
Limanond P, Raman SS, Ghobrial RM, Busuttil RW, Lu DS (2004) The utility of MRCP in preoperative mapping of biliary anatomy in adult-to-adult living related liver transplant donors. J Magn Reson Imaging 19:209–215
doi: 10.1002/jmri.10446 pubmed: 14745755
Morita S, Ueno E, Suzuki K et al (2008) Navigator-triggered prospective acquisition correction (PACE) technique vs. conventional respiratory-triggered technique for free-breathing 3D MRCP: an initial prospective comparative study using healthy volunteers. J Magn Reson Imaging 28:673–677
doi: 10.1002/jmri.21485 pubmed: 18777550
Zhang J, Israel GM, Hecht EM, Krinsky GA, Babb JS, Lee VS (2006) Isotropic 3D T2-weighted MR cholangiopancreatography with parallel imaging: feasibility study. AJR Am J Roentgenol 187:1564–1570
doi: 10.2214/AJR.05.1032 pubmed: 17114551
Weigel M, Hennig J (2006) Contrast behavior and relaxation effects of conventional and hyperecho-turbo spin echo sequences at 1.5 and 3 T. Magn Reson Med 55:826–835
doi: 10.1002/mrm.20816 pubmed: 16463351
Yokoyama K, Nakaura T, Iyama Y et al (2016) Usefulness of 3D hybrid profile order technique with 3T magnetic resonance cholangiography: Comparison of image quality and acquisition time. J Magn Reson Imaging 44:1346–1353
doi: 10.1002/jmri.25289 pubmed: 27131338
Chu ML, Chien CP, Wu WC, Chung HW (2019) Gradient- and spin-echo (GRASE) MR imaging: a long-existing technology that may find wide applications in modern era. Quant Imaging Med Surg 9:1477–1484
doi: 10.21037/qims.2019.09.13 pubmed: 31667134 pmcid: 6785504
Hirata K, Nakaura T, Okuaki T et al (2018) 3D hybrid profile order technique in a single breath-hold 3D T2-weighted fast spin-echo sequence: usefulness in diagnosis of small liver lesions. Eur J Radiol 98:113–117
doi: 10.1016/j.ejrad.2017.11.009 pubmed: 29279148
Yoshida M, Nakaura T, Inoue T et al (2018) Magnetic resonance cholangiopancreatography with GRASE sequence at 3.0T: does it improve image quality and acquisition time as compared with 3D TSE? Eur Radiol 28:2436–2443
doi: 10.1007/s00330-017-5240-y pubmed: 29335869
Uetani H, Nakaura T, Kitajima M et al (2021) A preliminary study of deep learning-based reconstruction specialized for denoising in high-frequency domain: usefulness in high-resolution three-dimensional magnetic resonance cisternography of the cerebellopontine angle. Neuroradiology 63:63–71
doi: 10.1007/s00234-020-02513-w pubmed: 32794075
Kim M, Kim HS, Kim HJ et al (2021) Thin-slice pituitary MRI with deep learning-based reconstruction: diagnostic performance in a postoperative setting. Radiology 298:114–122
doi: 10.1148/radiol.2020200723 pubmed: 33141001
Wang X, Ma J, Bhosale P et al (2021) Novel deep learning-based noise reduction technique for prostate magnetic resonance imaging. Abdom Radiol (NY) 46:3378–3386
doi: 10.1007/s00261-021-02964-6 pubmed: 33580348
Tajima T, Akai H, Sugawara H et al (2021) Breath-hold 3D magnetic resonance cholangiopancreatography at 1.5 T using a deep learning-based noise-reduction approach: Comparison with the conventional respiratory-triggered technique. Eur J Radiol 144:109994
Mugler JP 3rd (2014) Optimized three-dimensional fast-spin-echo MRI. J Magn Reson Imaging 39:745–767
doi: 10.1002/jmri.24542 pubmed: 24399498
Kidoh M, Shinoda K, Kitajima M et al (2020) Deep learning based noise reduction for brain mr imaging: tests on phantoms and healthy volunteers. Magn Reson Med Sci 19:195–206
doi: 10.2463/mrms.mp.2019-0018 pubmed: 31484849
Deshmane A, Gulani V, Griswold MA, Seiberlich N (2012) Parallel MR imaging. J Magn Reson Imaging 36:55–72
doi: 10.1002/jmri.23639 pubmed: 22696125 pmcid: 4459721
Willinek WA, Gieseke J, von Falkenhausen M, Neuen B, Schild HH, Kuhl CK (2003) Sensitivity encoding for fast MR imaging of the brain in patients with stroke. Radiology 228:669–675
doi: 10.1148/radiol.2283020243 pubmed: 12881577
Chen Z, Sun B, Xue Y et al (2021) Comparing compressed sensing breath-hold 3D MR cholangiopancreatography with two parallel imaging MRCP strategies in main pancreatic duct and common bile duct. Eur J Radiol 142:109833
doi: 10.1016/j.ejrad.2021.109833 pubmed: 34218123
Nakaura T, Kidoh M, Maruyama N et al (2013) Usefulness of the SPACE pulse sequence at 1.5T MR cholangiography: comparison of image quality and image acquisition time with conventional 3D-TSE sequence. J Magn Reson Imaging 38:1014–1019
doi: 10.1002/jmri.24033 pubmed: 24105679
Yoshikawa T, Mitchell DG, Hirota S et al (2006) Focal liver lesions: breathhold gradient- and spin-echo T2-weighted imaging for detection and characterization. J Magn Reson Imaging 23:520–528
doi: 10.1002/jmri.20544 pubmed: 16523481
Jung G, Krahe T, Kugel H et al (1997) Prospective comparison of fast SE and GRASE sequences and echo planar imaging with conventional SE sequences in the detection of focal liver lesions at 1.0 T. J Comput Assist Tomogr 21:341–347
doi: 10.1097/00004728-199705000-00002 pubmed: 9135638
Mezrich R (1995) A perspective on K-space. Radiology 195:297–315
doi: 10.1148/radiology.195.2.7724743 pubmed: 7724743
Caparelli EC, Tomasi D (2008) K-space spatial low-pass filters can increase signal loss artifacts in Echo-Planar Imaging. Biomed Signal Process Control 3:107–114
doi: 10.1016/j.bspc.2007.11.003 pubmed: 19122745 pmcid: 2350228
Moratal D, Valles-Luch A, Marti-Bonmati L, Brummer M (2008) k-Space tutorial: an MRI educational tool for a better understanding of k-space. Biomed Imaging Interv J 4:e15
doi: 10.2349/biij.4.1.e15 pubmed: 21614308 pmcid: 3097694
Tokoro H, Yamada A, Suzuki T et al (2020) Usefulness of breath-hold compressed sensing accelerated three-dimensional magnetic resonance cholangiopancreatography (MRCP) added to respiratory-gating conventional MRCP. Eur J Radiol 122:108765
doi: 10.1016/j.ejrad.2019.108765 pubmed: 31830630
Lohofer FK, Kaissis GA, Rasper M et al (2019) Magnetic resonance cholangiopancreatography at 3 Tesla: image quality comparison between 3D compressed sensing and 2D single-shot acquisitions. Eur J Radiol 115:53–58
doi: 10.1016/j.ejrad.2019.04.002 pubmed: 31084759

Auteurs

Kaori Shiraishi (K)

Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, Honjo 1-1-1, Kumamoto, 860-8556, Japan.

Takeshi Nakaura (T)

Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, Honjo 1-1-1, Kumamoto, 860-8556, Japan. kff00712@nifty.com.

Hiroyuki Uetani (H)

Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, Honjo 1-1-1, Kumamoto, 860-8556, Japan.

Yasunori Nagayama (Y)

Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, Honjo 1-1-1, Kumamoto, 860-8556, Japan.

Masafumi Kidoh (M)

Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, Honjo 1-1-1, Kumamoto, 860-8556, Japan.

Naoki Kobayashi (N)

Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, Honjo 1-1-1, Kumamoto, 860-8556, Japan.

Kosuke Morita (K)

Department of Radiology, Kumamoto University Hospital, Kumamoto, Japan, Honjo 1-1-1, Kumamoto, Japan.

Yuichi Yamahita (Y)

Canon Medical Systems Corporation, 70-1, Yanagi-Cho, Saiwai-Ku, Kawasaki-Shi, Kanagawa, 212-0015, Japan.

Yasuhito Tanaka (Y)

Department of Gastroenterology and Hepatology, Graduate School of Medical Sciences, Kumamoto University, Kumamoto, Japan.

Hideo Baba (H)

Department of Gastroenterological Surgery, Graduate School of Medical Sciences, Kumamoto University, Kumamoto, Japan.

Toshinori Hirai (T)

Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, Honjo 1-1-1, Kumamoto, 860-8556, Japan.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH