Diagnostic accuracy of two-dimensional and three-dimensional transesophageal echocardiography in detecting pannus and thrombus in left mechanical valve obstruction.
left mechanical valve obstruction
pannus
prosthetic valve complication
three-dimensional transesophageal echocardiography
thrombus
Journal
Annals of medicine and surgery (2012)
ISSN: 2049-0801
Titre abrégé: Ann Med Surg (Lond)
Pays: England
ID NLM: 101616869
Informations de publication
Date de publication:
May 2023
May 2023
Historique:
medline:
25
5
2023
pubmed:
25
5
2023
entrez:
25
5
2023
Statut:
epublish
Résumé
The aim of this study was to determine the accuracy of two-dimensional and three-dimensional transesophageal echocardiography (TEE) in the detection of pannus and thrombus in left mechanical valve obstruction (LMVO) compared with surgical and histopathology findings. Patients with suspected LMVO on transthoracic echocardiography were enrolled consecutively. All patients underwent two-dimensional and three-dimensional TEE, and open-heart surgery to replace obstructed valves. Macroscopic and microscopic analysis of the excised masses was used as the gold standard for the diagnosis of thrombus and/or pannus. Forty-eight patients [34 women (70.8%), age 49±13 years, New York Heart Association II: 68.8%, New York Heart Association III: 31.2%] were enrolled. In the diagnostic of thrombus, the sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of three-dimensional TEE were 89.2, 72.7, 85.4, 91.7, and 66.7%, respectively, compared with those of two-dimensional TEE (42.2, 66.7, 43.8, 95, and 7.1%, respectively). In the diagnosis of pannus, the sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of three-dimensional TEE were 53.3, 100, 85.4, 100, and 82.5%, respectively; compared with those of two-dimensional TEE (7.4, 90.5, 43.8, 50, and 43.2%, respectively). Receiver operating characteristic curves depict that the area under the curves of three-dimensional TEE was higher than the area under the curves of two-dimensional TEE in both diagnoses of thrombus and pannus (0.8560 vs. 0.7330, This study indicated that three-dimensional TEE had a higher diagnostic value than two-dimensional TEE in the detection of thrombus and pannus in patients with LMVO, and can be a reliable imaging modality to identify the causes of LMVO.
Identifiants
pubmed: 37228979
doi: 10.1097/MS9.0000000000000601
pmc: PMC10205352
doi:
Types de publication
Journal Article
Langues
eng
Pagination
1358-1365Informations de copyright
Copyright © 2023 the Author(s). Published by Wolters Kluwer Health, Inc.
Déclaration de conflit d'intérêts
The authors declare that they have no financial conflict of interest with regard to the content of this report.
Références
Am J Cardiol. 2013 Oct 1;112(7):977-83
pubmed: 23800549
J Am Coll Cardiol. 2016 Dec 20;68(24):2670-2689
pubmed: 27978952
Int J Cardiovasc Imaging. 2015 Aug;31(6):1271-80
pubmed: 25990093
World J Cardiol. 2015 Dec 26;7(12):875-81
pubmed: 26730292
J Am Coll Cardiol. 1998 Nov;32(5):1410-7
pubmed: 9809956
J Heart Valve Dis. 2005 Sep;14(5):664-73
pubmed: 16245506
Ann Thorac Surg. 1997 Apr;63(4):1101-6
pubmed: 9124913
J Am Coll Cardiol. 1992 Dec;20(7):1503-11
pubmed: 1452923
Int J Cardiol. 2017 Dec 15;249:344-348
pubmed: 28950994
J Cardiovasc Comput Tomogr. 2016 Sep-Oct;10(5):398-406
pubmed: 27452311
J Am Coll Cardiol. 1991 Mar 1;17(3):646-50
pubmed: 1993782
BMJ Case Rep. 2015 Sep 21;2015:
pubmed: 26392458
J Card Surg. 2007 May-Jun;22(3):218
pubmed: 17488418
J Thorac Cardiovasc Surg. 2003 Aug;126(2):401-7
pubmed: 12928636
Echocardiography. 2011 Aug;28(7):E146-8
pubmed: 21752090
Circulation. 2009 Feb 24;119(7):1034-48
pubmed: 19237674
Circulation. 2007 May 22;115(20):2637-41
pubmed: 17485579
JACC Cardiovasc Imaging. 2015 Dec;8(12):1461-1464
pubmed: 26699114
J Am Coll Cardiol. 2021 Feb 2;77(4):e25-e197
pubmed: 33342586
JACC Cardiovasc Imaging. 2019 Nov;12(11 Pt 1):2182-2192
pubmed: 30772236
Eur Heart J Cardiovasc Imaging. 2016 Jun;17(6):589-90
pubmed: 27143783