Edge-to-Edge Transcatheter Mitral Valve Repair Using PASCAL vs. MitraClip: A Systematic Review and Meta-Analysis.
MitraClip
PASCAL
mitral regurgitation
transcatheter edge-to-edge repair
Journal
Journal of clinical medicine
ISSN: 2077-0383
Titre abrégé: J Clin Med
Pays: Switzerland
ID NLM: 101606588
Informations de publication
Date de publication:
20 May 2023
20 May 2023
Historique:
received:
19
04
2023
revised:
12
05
2023
accepted:
18
05
2023
medline:
27
5
2023
pubmed:
27
5
2023
entrez:
27
5
2023
Statut:
epublish
Résumé
Transcatheter edge-to-edge repair (TEER) of the mitral valve (MV) can be performed using the PASCAL or MitraClip devices. Few studies offer a head-to-head outcome comparison of these two devices. PubMed, EMBASE, Cochrane Library, Clinicaltrials.gov and WHO's International Clinical Trials Registry Platform, from 1 January 2000 until 1 March 2023, were searched. Study protocol details were registered in the International Prospective Register of Systematic Reviews (PROSPERO ID: CRD42023405400). Randomized Controlled Trials and observational studies reporting head-to-head clinical comparison of PASCAL and MitraClip devices were eligible for selection. Patients with severe functional or degenerative mitral regurgitation (MR) who had undergone TEER of the MV with either PASCAL or MitraClip devices were included in the meta-analysis. Data from six studies (five observational and one randomized clinical trial) were extracted and analyzed. The main outcomes were a reduction in MR to 2+ or less, improvement of New York Heart Association (NYHA) and 30-day all-cause mortality. Peri-procedural mortality, success rate and adverse events were also compared. Data from 785 and 796 patients that underwent TEER using PASCAL and MitraClip, respectively, were analyzed. Thirty-day all-cause mortality (Risk ratio [RR] = 1.51, 95% CI 0.79-2.89), MR reduction to maximum 2+ (RR = 1.00, 95% CI 0.98-1.02) and NYHA improvement (RR = 0.98, 95% CI 0.84-1.15) were similar in both device groups. Both devices had high and similar success rates (96.9% and 96.7% for the PASCAL and MitraClip group, respectively, Both PASCAL and MitraClip devices have high success and low complication rates for TEER of the MV. PASCAL was not inferior to MitraClip in reducing the MR level at discharge.
Sections du résumé
BACKGROUND
BACKGROUND
Transcatheter edge-to-edge repair (TEER) of the mitral valve (MV) can be performed using the PASCAL or MitraClip devices. Few studies offer a head-to-head outcome comparison of these two devices.
MATERIAL AND METHODS
METHODS
PubMed, EMBASE, Cochrane Library, Clinicaltrials.gov and WHO's International Clinical Trials Registry Platform, from 1 January 2000 until 1 March 2023, were searched. Study protocol details were registered in the International Prospective Register of Systematic Reviews (PROSPERO ID: CRD42023405400). Randomized Controlled Trials and observational studies reporting head-to-head clinical comparison of PASCAL and MitraClip devices were eligible for selection. Patients with severe functional or degenerative mitral regurgitation (MR) who had undergone TEER of the MV with either PASCAL or MitraClip devices were included in the meta-analysis. Data from six studies (five observational and one randomized clinical trial) were extracted and analyzed. The main outcomes were a reduction in MR to 2+ or less, improvement of New York Heart Association (NYHA) and 30-day all-cause mortality. Peri-procedural mortality, success rate and adverse events were also compared.
RESULTS
RESULTS
Data from 785 and 796 patients that underwent TEER using PASCAL and MitraClip, respectively, were analyzed. Thirty-day all-cause mortality (Risk ratio [RR] = 1.51, 95% CI 0.79-2.89), MR reduction to maximum 2+ (RR = 1.00, 95% CI 0.98-1.02) and NYHA improvement (RR = 0.98, 95% CI 0.84-1.15) were similar in both device groups. Both devices had high and similar success rates (96.9% and 96.7% for the PASCAL and MitraClip group, respectively,
CONCLUSIONS
CONCLUSIONS
Both PASCAL and MitraClip devices have high success and low complication rates for TEER of the MV. PASCAL was not inferior to MitraClip in reducing the MR level at discharge.
Identifiants
pubmed: 37240685
pii: jcm12103579
doi: 10.3390/jcm12103579
pmc: PMC10219028
pii:
doi:
Types de publication
Journal Article
Review
Langues
eng
Références
J Thorac Cardiovasc Surg. 2015 Mar;149(3):675-7
pubmed: 25623909
Open Heart. 2021 Apr;8(1):
pubmed: 33911022
Innovations (Phila). 2018 Nov/Dec;13(6):433-437
pubmed: 30543578
Stat Methods Med Res. 2018 Jun;27(6):1785-1805
pubmed: 27683581
BMJ. 2021 Mar 29;372:n71
pubmed: 33782057
Ann Cardiothorac Surg. 2021 Jan;10(1):15-27
pubmed: 33575172
Clin Res Cardiol. 2021 Dec;110(12):1890-1899
pubmed: 33837469
N Engl J Med. 2011 Apr 14;364(15):1395-406
pubmed: 21463154
Heart. 2006 Oct;92(10):1369-72
pubmed: 16339816
BMC Cardiovasc Disord. 2017 Mar 20;17(1):85
pubmed: 28320316
Indian Heart J. 2021 Jan-Feb;73(1):129-131
pubmed: 33714399
JACC Cardiovasc Interv. 2022 Dec 26;15(24):2554-2567
pubmed: 36543450
N Engl J Med. 2018 Dec 13;379(24):2307-2318
pubmed: 30280640
BMC Med Res Methodol. 2014 Dec 19;14:135
pubmed: 25524443
JACC Cardiovasc Interv. 2022 May 9;15(9):1002-1004
pubmed: 35512912
JACC Cardiovasc Interv. 2022 Dec 26;15(24):2541-2551
pubmed: 36543448
J Thorac Cardiovasc Surg. 2022 Apr 13;:
pubmed: 35570022
Ann Cardiothorac Surg. 2021 Jan;10(1):1-14
pubmed: 33575171
BMJ. 2011 Oct 18;343:d5928
pubmed: 22008217
Catheter Cardiovasc Interv. 2021 Oct;98(4):E637-E646
pubmed: 34004077
ESC Heart Fail. 2022 Apr;9(2):853-865
pubmed: 35170230
J Am Coll Cardiol. 2015 Jul 21;66(3):308-321
pubmed: 26184623