Successful Endovascular Rescue Using the Brockenbrough Needle Following Inadvertent Stent-Graft Deployment in the False Lumen.
Brockenbrough needle
Endovascular rescue
False lumen implantation
Thoracic endovascular aortic repair (TEVAR)
Journal
The journal of Tehran Heart Center
ISSN: 1735-5370
Titre abrégé: J Tehran Heart Cent
Pays: Iran
ID NLM: 101289255
Informations de publication
Date de publication:
Jul 2022
Jul 2022
Historique:
received:
27
05
2021
accepted:
05
06
2022
medline:
30
5
2023
pubmed:
30
5
2023
entrez:
30
5
2023
Statut:
ppublish
Résumé
Inadvertent deployment of stent grafts into the false lumen during thoracic endovascular aortic repair (TEVAR) is rare and is associated with catastrophic consequences. We present a case of accidental stent-graft deployment from the true lumen into the false lumen during TEVAR, resulting in hemodynamic collapse and visceral malperfusion. We successfully performed a bailout using the Brockenbrough needle to create new access from the true lumen to the false lumen and implanted another overlapping stent graft.
Identifiants
pubmed: 37252085
doi: 10.18502/jthc.v17i3.10848
pii: JTHC-17-147
pmc: PMC10222941
doi:
Types de publication
Case Reports
Langues
eng
Pagination
147-151Informations de copyright
Copyright © 2022 Tehran University of Medical Sciences. Published by Tehran University of Medical Sciences.
Références
Br J Surg. 2010 May;97(5):657-63
pubmed: 20235086
J Vasc Surg. 2016 Feb;63(2):518-22
pubmed: 25595403
Circulation. 2010 Apr 6;121(13):e266-369
pubmed: 20233780
J Thorac Cardiovasc Surg. 2016 Mar;151(3):e41-e45
pubmed: 26651956
J Vasc Surg. 2011 Jan;53(1):187-92
pubmed: 20974523
J Vasc Surg. 2003 Mar;37(3):615-8
pubmed: 12618701
J Vasc Surg. 2014 Jan;59(1):264-7
pubmed: 24370086
Interact Cardiovasc Thorac Surg. 2010 Apr;10(4):597-9
pubmed: 20118121