Infective Endocarditis-Related Pseudoaneurysms After Bentall Surgery: The Role of 3D Printing in Pre-Surgical Planning and Management: Case Report.
3D printing
Bentall procedure
Infective endocarditis
Multimodality imaging
Pseudoaneurysms
Transesophageal echocardiography TEE
Journal
Journal of the Saudi Heart Association
ISSN: 1016-7315
Titre abrégé: J Saudi Heart Assoc
Pays: Saudi Arabia
ID NLM: 9887261
Informations de publication
Date de publication:
2023
2023
Historique:
received:
04
03
2023
revised:
08
04
2023
accepted:
10
04
2023
medline:
1
6
2023
pubmed:
1
6
2023
entrez:
1
6
2023
Statut:
epublish
Résumé
We present a case report of a male patient who underwent modified Bentall surgery with a mechanical valved conduit due to severe aortic regurgitation and ascending aortic aneurysm. Four years later, the patient developed a cascade of events as acute stoke, infective endocarditis due to
Identifiants
pubmed: 37260740
doi: 10.37616/2212-5043.1335
pii: sha66-70
pmc: PMC10229129
doi:
Types de publication
Case Reports
Langues
eng
Pagination
66-70Informations de copyright
© 2023 Saudi Heart Association.
Déclaration de conflit d'intérêts
Conflict of interest No conflict of interest.
Références
J Card Surg. 2022 Sep;37(9):2845-2848
pubmed: 35752940
Br J Radiol. 2019 Jan;92(1093):20180226
pubmed: 30048155
Ann Vasc Surg. 2018 Nov;53:243-254
pubmed: 30053547
J Card Surg. 2022 Jun;37(6):1773-1775
pubmed: 35286731
Aorta (Stamford). 2019 Jun;7(3):90-92
pubmed: 31614379
Thorax. 1968 Jul;23(4):338-9
pubmed: 5664694
Front Cardiovasc Med. 2021 Dec 01;8:745556
pubmed: 34926606
Ann Thorac Surg. 2016 May;101(5):1684-9
pubmed: 26857635
JAMA. 2007 Mar 28;297(12):1354-61
pubmed: 17392239