Pelvic floor ultrasound versus urodynamics in evaluating insensible urinary incontinence: A retrospective study.
Correlation of data
Corrélation des données
Cross-sectional studies
Diagnosis
Diagnostic
Incontinence urinaire
Ultrasonography
Urinary incontinence
Urodynamics
Urodynamique
Échographie
Études transversales
Journal
Progres en urologie : journal de l'Association francaise d'urologie et de la Societe francaise d'urologie
ISSN: 1166-7087
Titre abrégé: Prog Urol
Pays: France
ID NLM: 9307844
Informations de publication
Date de publication:
Jul 2023
Jul 2023
Historique:
received:
15
01
2023
revised:
09
05
2023
accepted:
13
05
2023
medline:
19
6
2023
pubmed:
5
6
2023
entrez:
4
6
2023
Statut:
ppublish
Résumé
Insensible Urinary Incontinence (IUI) is a situation when you complain of urinary incontinence but are unaware of how it occurred. Therefore, it is necessary to apply highly specific diagnostic methods to promote accuracy in the diagnosis of IUI, including pelvic floor ultrasound (PFU) and urodynamic studies (UDS). A total of 41 women with IUI were retrospectively included. Patients were categorized into two groups: the urodynamic urinary incontinence group (UUI group, n=20) and the non-urodynamic urinary incontinence group (NUUI group, n=21), according to the urine leakage during UDS. The baseline clinical characteristics, UDS results, and PFU parameters were collected. Compared with the NUUI group, the UUI group had a smaller maximum cystometric capacity (P=0.008), lower maximum urethral closure pressure (P=0.005), shorter functional urethral length (FUL) (P=0.01), more bladder neck funneling (BNF) (P=0.02), greater BNF depth (P=0.04), and larger BNF area (P=0.01). The area and depth of BNF were negatively correlated with maximum urethral closure pressure (r=-0.42, P=0.01), FUL (r=-0.36, P=0.02 versus r=-0.39, P=0.01), and maximum cystometric capacity (r=-0.35, P=0.03), but positively correlated with maximum urinary flow rate (r=0.33, P=0.04 versus r=0.36, P=0.02). The canonical correlation analysis of the ultrasound parameters and UDS parameters shows that the first pair of canonical variables was statistically significant (r1=0.9, P<0.001). The PFU is associated with UDS in evaluating IUI. It has the advantages of low cost and high comfort, thus should be used as an auxiliary examination for IUI.
Identifiants
pubmed: 37271669
pii: S1166-7087(23)00106-9
doi: 10.1016/j.purol.2023.05.002
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
384-392Informations de copyright
Copyright © 2023. Published by Elsevier Masson SAS.