Transatlantic multicenter study on the use of a modified preloaded delivery system for fenestrated endovascular aortic repair.
Humans
Male
Aged
Female
Blood Vessel Prosthesis
Blood Vessel Prosthesis Implantation
Endovascular Aneurysm Repair
Aortic Aneurysm, Abdominal
/ diagnostic imaging
Aortic Aneurysm, Thoracic
/ diagnostic imaging
Retrospective Studies
Cohort Studies
Endovascular Procedures
Treatment Outcome
Time Factors
Aortic Aneurysm, Thoracoabdominal
Prosthesis Design
Aortic aneurysm
FEVAR
Fenestrated aortic repair
Modified delivery system
Preloaded
Journal
Journal of vascular surgery
ISSN: 1097-6809
Titre abrégé: J Vasc Surg
Pays: United States
ID NLM: 8407742
Informations de publication
Date de publication:
10 2023
10 2023
Historique:
received:
01
05
2023
revised:
23
05
2023
accepted:
24
05
2023
medline:
25
9
2023
pubmed:
18
6
2023
entrez:
18
6
2023
Statut:
ppublish
Résumé
Analyze the outcomes of endovascular complex abdominal and thoracoabdominal aortic aneurysm repair using the Cook fenestrated device with the modified preloaded delivery system (MPDS) with a biport handle and preloaded catheters. A multicenter retrospective single arm cohort study was performed, including all consecutive patients with complex abdominal aortic aneurysm repair and thoracoabdominal aortic aneurysms treated with the MPDS fenestrated device (Cook Medical). Patient clinical characteristics, anatomy, and indications for device use were collected. Outcomes, classified according to the Society for Vascular Surgery reporting standards, were collected at discharge, 30 days, 6 months, and annually thereafter. Overall, 712 patients (median age, 73 years; interquartile range [IQR], 68-78 years; 83% male) from 16 centers in Europe and the United States treated electively were included: 35.4% (n = 252) presented with thoracoabdominal aortic aneurysms and 64.6% (n = 460) with complex abdominal aortic aneurysm repair. Overall, 2755 target vessels were included (mean ,3.9 per patient). Of these, 1628 were incorporated via ipsilateral preloads using the MPDS (1440 accessed from the biport handle and 188 from above). The mean size of the contralateral femoral sheath during target vessel catheterization was 15F ± 4, and in 41 patients (6.7%) the sheath size was ≤8F. Technical success was 96.1%. Median procedural time was 209 minutes (IQR, 161-270 minutes), contrast volume was 100 mL (IQR, 70-150mL), fluoroscopy time was 63.9 minutes (IQR, 49.7-80.4 minutes) and median cumulative air kerma radiation dose was 2630 mGy (IQR, 838-5251 mGy). Thirty-day mortality was 4.8% (n = 34). Access complications occurred in 6.8% (n = 48) and 30-day reintervention in 7% (n = 50; 18 branch related). Follow-up of >30 days was available for 628 patients (88%), with a median follow-up of 19 months (IQR, 8-39 months). Branch-related endoleaks (type Ic/IIIc) were observed in 15 patients (2.6%) and aneurysm growth of >5 mm was observed in 54 (9.5%). Freedom from reintervention at 12 and 24 months was 87.1% (standard error [SE],1.5%) and 79.2% (SE, 2.0%), respectively. Overall target vessel patency at 12 and 24 months was 98.6% (SE, 0.3%) and 96.8% (SE, 0.4%), respectively, and was 97.9% (SE, 0.4%) and 95.3% (SE, 0.8%) for arteries stented from below using the MPDS, respectively. The MPDS is safe and effective. Overall benefits include a decrease in contralateral sheath size in the treatment of complex anatomies with favorable results.
Identifiants
pubmed: 37330705
pii: S0741-5214(23)01278-8
doi: 10.1016/j.jvs.2023.05.043
pii:
doi:
Types de publication
Multicenter Study
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
863-873.e3Informations de copyright
Copyright © 2023 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.