A 3D Printed, Bionic Hand Powered by EMG Signals and Controlled by an Online Neural Network.
artificial intelligence
bionic hand
electromyography
neural network
real-time classification
Journal
Biomimetics (Basel, Switzerland)
ISSN: 2313-7673
Titre abrégé: Biomimetics (Basel)
Pays: Switzerland
ID NLM: 101719189
Informations de publication
Date de publication:
14 Jun 2023
14 Jun 2023
Historique:
received:
18
05
2023
revised:
07
06
2023
accepted:
08
06
2023
medline:
27
6
2023
pubmed:
27
6
2023
entrez:
27
6
2023
Statut:
epublish
Résumé
About 8% of the Ecuadorian population suffers some type of amputation of upper or lower limbs. Due to the high cost of a prosthesis and the fact that the salary of an average worker in the country reached 248 USD in August 2021, they experience a great labor disadvantage and only 17% of them are employed. Thanks to advances in 3D printing and the accessibility of bioelectric sensors, it is now possible to create economically accessible proposals. This work proposes the design of a hand prosthesis that uses electromyography (EMG) signals and neural networks for real-time control. The integrated system has a mechanical and electronic design, and the latter integrates artificial intelligence for control. To train the algorithm, an experimental methodology was developed to record muscle activity in upper extremities associated with specific tasks, using three EMG surface sensors. These data were used to train a five-layer neural network. the trained model was compressed and exported using TensorflowLite. The prosthesis consisted of a gripper and a pivot base, which were designed in Fusion 360 considering the movement restrictions and the maximum loads. It was actuated in real time thanks to the design of an electronic circuit that used an ESP32 development board, which was responsible for recording, processing and classifying the EMG signals associated with a motor intention, and to actuate the hand prosthesis. As a result of this work, a database with 60 electromyographic activity records from three tasks was released. The classification algorithm was able to detect the three muscle tasks with an accuracy of 78.67% and a response time of 80 ms. Finally, the 3D printed prosthesis was able to support a weight of 500 g with a safety factor equal to 15.
Identifiants
pubmed: 37366850
pii: biomimetics8020255
doi: 10.3390/biomimetics8020255
pmc: PMC10296662
pii:
doi:
Types de publication
Journal Article
Langues
eng
Références
PLoS One. 2017 Oct 12;12(10):e0186132
pubmed: 29023548
Diagnostics (Basel). 2021 May 21;11(6):
pubmed: 34063774
J Med Eng Technol. 2016 Jul;40(5):255-64
pubmed: 27098838
J Rehabil Res Dev. 2013;50(5):599-618
pubmed: 24013909
IEEE Trans Biomed Eng. 2014 Apr;61(4):1167-76
pubmed: 24658241
IEEE Trans Neural Syst Rehabil Eng. 2019 Apr;27(4):760-771
pubmed: 30714928
J Neurosci Methods. 2006 Sep 30;156(1-2):360-7
pubmed: 16621003
PLoS One. 2017 Apr 3;12(4):e0174670
pubmed: 28369104
Micromachines (Basel). 2022 Oct 06;13(10):
pubmed: 36296034
Sensors (Basel). 2019 Oct 22;19(20):
pubmed: 31652616
Artif Organs. 2019 Feb;43(2):109-118
pubmed: 30653695
Biol Proced Online. 2006;8:11-35
pubmed: 16799694
Prosthet Orthot Int. 2018 Feb;42(1):66-74
pubmed: 28190380
Sensors (Basel). 2023 Apr 12;23(8):
pubmed: 37112246
Plast Reconstr Surg. 2017 Oct;140(4):865
pubmed: 28953744
Front Neurosci. 2016 May 12;10:209
pubmed: 27242413
Front Neurol. 2020 Oct 15;11:576729
pubmed: 33178118
Sensors (Basel). 2022 Mar 04;22(5):
pubmed: 35271175
Sensors (Basel). 2018 Aug 25;18(9):
pubmed: 30149621
Sensors (Basel). 2018 May 18;18(5):
pubmed: 29783659