Effect of humeral rotation on the reliability of radiographic measurements for proximal humerus fractures.
Intra-class correlation
Proximal humerus fracture
Radiograph
Reliability
Rotation
Shoulder
Surgery
Journal
Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association
ISSN: 1436-2023
Titre abrégé: J Orthop Sci
Pays: Japan
ID NLM: 9604934
Informations de publication
Date de publication:
30 Jun 2023
30 Jun 2023
Historique:
received:
29
12
2022
revised:
18
05
2023
accepted:
14
06
2023
medline:
2
7
2023
pubmed:
2
7
2023
entrez:
1
7
2023
Statut:
aheadofprint
Résumé
There are concerns as to the reliability of proximal humerus radiographic measurements, particularly regarding the rotational position of the humerus when obtaining radiographs. Twenty-four patients with proximal humerus fractures fixed surgically with locked plates received postoperative anteroposterior radiographs with the humerus in neutral rotation and in 30° of internal and external rotation. Radiographic measurements for head shaft angle, humeral offset and humeral head height were performed in each humeral rotation position. Intra-class correlation coefficient was used to assess inter-rater and intra-rater reliability. Mean differences (md) in measurements between humeral positions was evaluated using one-way ANOVA. Head shaft angle demonstrated good-to-excellent reliability; the highest estimates for inter-rater reliability (ICC: 0.85; 95% CI: 0.76, 0.94) and intra-rater reliability (ICC: 0.96; 95% CI: 0.93, 0.98) were achieved in neutral rotation. There were significant differences in measurement values between each rotational position, with mean head shaft angle of 133.1° in external rotation, and increasingly valgus measurements in neutral (md: 7.6°; 95% CI: 5.0, 10.3°; p < 0.001) and internal rotation (md: 26.4°; 95% CI: 21.8, 30.9°; p < 0.001). Humeral head height and humeral offset showed good-to-excellent reliability in neutral and external rotation, but poor inter-rater reliability in internal rotation. Humeral head height was significantly greater using internal compared to external rotation (md: 4.5 mm; 95% CI: 1.7, 7.3 mm; p = 0.002). Humeral offset was significantly greater in external compared to internal rotation (md: 4.6 mm; 95% CI: 2.6, 6.6 mm; p < 0.001). Views of the humerus in neutral rotation and 30° of external rotation displayed superior reliability. Differences in radiographic measurement values, depending on humeral rotation views, can make for problematic correlations with patient outcome measures. Studies assessing radiographic outcomes following proximal humerus fractures should ensure standardized humeral rotation for obtaining anteroposterior shoulder radiographs, with neutral rotation and external rotation views likely yielding the most reliable results. Level IV.
Sections du résumé
BACKGROUND
BACKGROUND
There are concerns as to the reliability of proximal humerus radiographic measurements, particularly regarding the rotational position of the humerus when obtaining radiographs.
METHODS
METHODS
Twenty-four patients with proximal humerus fractures fixed surgically with locked plates received postoperative anteroposterior radiographs with the humerus in neutral rotation and in 30° of internal and external rotation. Radiographic measurements for head shaft angle, humeral offset and humeral head height were performed in each humeral rotation position. Intra-class correlation coefficient was used to assess inter-rater and intra-rater reliability. Mean differences (md) in measurements between humeral positions was evaluated using one-way ANOVA.
RESULTS
RESULTS
Head shaft angle demonstrated good-to-excellent reliability; the highest estimates for inter-rater reliability (ICC: 0.85; 95% CI: 0.76, 0.94) and intra-rater reliability (ICC: 0.96; 95% CI: 0.93, 0.98) were achieved in neutral rotation. There were significant differences in measurement values between each rotational position, with mean head shaft angle of 133.1° in external rotation, and increasingly valgus measurements in neutral (md: 7.6°; 95% CI: 5.0, 10.3°; p < 0.001) and internal rotation (md: 26.4°; 95% CI: 21.8, 30.9°; p < 0.001). Humeral head height and humeral offset showed good-to-excellent reliability in neutral and external rotation, but poor inter-rater reliability in internal rotation. Humeral head height was significantly greater using internal compared to external rotation (md: 4.5 mm; 95% CI: 1.7, 7.3 mm; p = 0.002). Humeral offset was significantly greater in external compared to internal rotation (md: 4.6 mm; 95% CI: 2.6, 6.6 mm; p < 0.001).
CONCLUSIONS
CONCLUSIONS
Views of the humerus in neutral rotation and 30° of external rotation displayed superior reliability. Differences in radiographic measurement values, depending on humeral rotation views, can make for problematic correlations with patient outcome measures. Studies assessing radiographic outcomes following proximal humerus fractures should ensure standardized humeral rotation for obtaining anteroposterior shoulder radiographs, with neutral rotation and external rotation views likely yielding the most reliable results.
LEVEL OF EVIDENCE
METHODS
Level IV.
Identifiants
pubmed: 37393111
pii: S0949-2658(23)00179-3
doi: 10.1016/j.jos.2023.06.006
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Informations de copyright
Copyright © 2023 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
Déclaration de conflit d'intérêts
Declaration of competing interest None.