Balloon Pressure Technique with the Scepter Mini Balloon as Part of the Endovascular Strategy for Brain Arteriovenous Malformations Embolization : Preliminary Multicenter Experience.

EVOH Embolization Image-guided procedure Interventional Liquid embolic agent Vascular disease

Journal

Clinical neuroradiology
ISSN: 1869-1447
Titre abrégé: Clin Neuroradiol
Pays: Germany
ID NLM: 101526693

Informations de publication

Date de publication:
Dec 2023
Historique:
received: 24 08 2022
accepted: 16 05 2023
pubmed: 4 7 2023
medline: 4 7 2023
entrez: 4 7 2023
Statut: ppublish

Résumé

The balloon pressure technique (BPT) is an alternative to the pressure cooker technique. A dual lumen balloon (DLB) is used to inject the liquid embolic agent through the working lumen while the balloon is inflated. The purpose of our study was to report our early experience using the Scepter Mini dual lumen balloons for BPT in brain arteriovenous malformation (bAVM) embolization. Consecutive patients treated from July 2020 to July 2021 in 3 tertiary centers using the BPT with low-profile dual lumen balloons (Scepter Mini, Microvention, Tustin, CA, USA) by endovascular means for bAVMs were retrospectively reviewed. Patient demographics and bAVM angio-architectural features were collected. The feasibility of Scepter Mini balloon navigation close to the nidus was evaluated. Technical as well as clinical (ischemic and/or hemorrhagic) complications were also systematically assessed. The occlusion rate was evaluated on follow-up DSA. A total of 19 patients (10 females; mean age = 38.2 years) consecutively treated for a bAVM (8 ruptured/11 unruptured) using the BPT with a Scepter Mini through 23 embolization sessions were included in our series. Navigation of the Scepter Mini was feasible in all cases. Of the patients 3 (16%) had procedure-related ischemic stroke and 2 patients (10.5%) had late hemorrhages. None of these complications led to severe permanent sequela. Complete occlusion of bAVM embolized with intention to cure was recorded in 11/13 cases (84.6%). The BPT using low-profile dual lumen balloons is feasible and seems safe for embolization of bAVMs. It may help to reach high occlusion rates, especially when performed in the intent to cure by embolization only.

Sections du résumé

BACKGROUND BACKGROUND
The balloon pressure technique (BPT) is an alternative to the pressure cooker technique. A dual lumen balloon (DLB) is used to inject the liquid embolic agent through the working lumen while the balloon is inflated. The purpose of our study was to report our early experience using the Scepter Mini dual lumen balloons for BPT in brain arteriovenous malformation (bAVM) embolization.
MATERIAL AND METHODS METHODS
Consecutive patients treated from July 2020 to July 2021 in 3 tertiary centers using the BPT with low-profile dual lumen balloons (Scepter Mini, Microvention, Tustin, CA, USA) by endovascular means for bAVMs were retrospectively reviewed. Patient demographics and bAVM angio-architectural features were collected. The feasibility of Scepter Mini balloon navigation close to the nidus was evaluated. Technical as well as clinical (ischemic and/or hemorrhagic) complications were also systematically assessed. The occlusion rate was evaluated on follow-up DSA.
RESULTS RESULTS
A total of 19 patients (10 females; mean age = 38.2 years) consecutively treated for a bAVM (8 ruptured/11 unruptured) using the BPT with a Scepter Mini through 23 embolization sessions were included in our series. Navigation of the Scepter Mini was feasible in all cases. Of the patients 3 (16%) had procedure-related ischemic stroke and 2 patients (10.5%) had late hemorrhages. None of these complications led to severe permanent sequela. Complete occlusion of bAVM embolized with intention to cure was recorded in 11/13 cases (84.6%).
CONCLUSION CONCLUSIONS
The BPT using low-profile dual lumen balloons is feasible and seems safe for embolization of bAVMs. It may help to reach high occlusion rates, especially when performed in the intent to cure by embolization only.

Identifiants

pubmed: 37401950
doi: 10.1007/s00062-023-01309-8
pii: 10.1007/s00062-023-01309-8
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

1055-1065

Informations de copyright

© 2023. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany.

Références

Pollock BE, Flickinger JC, Lunsford LD, et al. Factors that predict the bleeding risk of cerebral arteriovenous malformations. Stroke. 1996;27(1):1–6. https://doi.org/10.1161/01.str.27.1.1 .
doi: 10.1161/01.str.27.1.1 pubmed: 8553382
Al-Shahi R, Bhattacharya JJ, Currie DG, et al. Prospective, population-based detection of intracranial vascular malformations in adults: the Scottish Intracranial Vascular Malformation Study (SIVMS). Stroke. 2003;34(5):1163–9. https://doi.org/10.1161/01.STR.0000069018.90456.C9 .
doi: 10.1161/01.STR.0000069018.90456.C9 pubmed: 12702837
Solomon RA, Connolly ES Jr. Arteriovenous malformations of the brain. N Engl J Med. 2017;376(19):1859–66. https://doi.org/10.1056/NEJMra1607407 . published Online First: 2017/05/11.
doi: 10.1056/NEJMra1607407 pubmed: 28489992
Shotar E, Debarre M, Sourour NA, et al. Retrospective study of long-term outcome after brain arteriovenous malformation rupture: the RAP score. J Neurosurg. 2018;128(1):78–85. https://doi.org/10.3171/2016.9.JNS161431 .
doi: 10.3171/2016.9.JNS161431 pubmed: 28106499
Hashimoto N, Nozaki K, Takagi Y, et al. Surgery of cerebral arteriovenous malformations. Neurosurgery. 2007;61(1 Suppl):375–87. https://doi.org/10.1227/01.NEU.0000255491.95944.EB . discussion 87–9.
doi: 10.1227/01.NEU.0000255491.95944.EB pubmed: 18813152
Raymond J, Iancu D, Weill A, et al. Embolization as one modality in a combined strategy for the management of cerebral arteriovenous malformations. Interv Neuroradiol. 2005;11(Suppl 1):57–62. https://doi.org/10.1177/15910199050110S110 .
doi: 10.1177/15910199050110S110 pubmed: 20584461 pmcid: 3404768
Pierot L, Cognard C, Herbreteau D, et al. Endovascular treatment of brain arteriovenous malformations using a liquid embolic agent: results of a prospective, multicentre study (BRAVO). Eur Radiol. 2013;23(10):2838–45. https://doi.org/10.1007/s00330-013-2870-6 .
doi: 10.1007/s00330-013-2870-6 pubmed: 23652849
Chapot R, Stracke P, Velasco A, et al. The pressure cooker technique for the treatment of brain AVMs. J Neuroradiol. 2014;41(1):87–91. https://doi.org/10.1016/j.neurad.2013.10.001 .
doi: 10.1016/j.neurad.2013.10.001 pubmed: 24405685
Koyanagi M, Mosimann PJ, Nordmeyer H, et al. The transvenous retrograde pressure cooker technique for the curative embolization of high-grade brain arteriovenous malformations. J Neurointerv Surg. 2021;13(7):637–41. https://doi.org/10.1136/neurintsurg-2020-016566 .
doi: 10.1136/neurintsurg-2020-016566 pubmed: 32900907
He Y, Bai W, Xu B, et al. Perioperative complications of transvenous embolization of ruptured Intracranial arteriovenous malformations. Front Neurol. 2022; https://doi.org/10.3389/fneur.2022.873186 .
doi: 10.3389/fneur.2022.873186 pubmed: 37008043 pmcid: 9810494
Clarencon F, Perot G, Biondi A, et al. Use of the Ascent balloon for a 2-in‑1 remodeling technique: feasibility and initial experience: case report. Neurosurgery. 2012;70(1 Suppl Operative):170–3. https://doi.org/10.1227/NEU.0b013e31822c49ad . discussion 73.
doi: 10.1227/NEU.0b013e31822c49ad pubmed: 22343831
Clarencon F, Di Maria F, Gabrieli J, et al. Double-lumen balloon for Onyx(R) embolization via extracranial arteries in transverse sigmoid dural arteriovenous fistulas: initial experience. Acta Neurochir. 2016;158(10):1917–23. https://doi.org/10.1007/s00701-016-2906-1 .
doi: 10.1007/s00701-016-2906-1 pubmed: 27522356
Paramasivam S, Niimi Y, Fifi J, et al. Onyx embolization using dual-lumen balloon catheter: initial experience and technical note. J Neuroradiol. 2013;40(4):294–302. https://doi.org/10.1016/j.neurad.2013.08.001 .
doi: 10.1016/j.neurad.2013.08.001 pubmed: 24074560
von Elm E, Altman DG, Egger M, et al. The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement: guidelines for reporting observational studies. Ann Intern Med. 2007;147(8):573–7. https://doi.org/10.7326/0003-4819-147-8-200710160-00010 .
doi: 10.7326/0003-4819-147-8-200710160-00010
Spetzler RF, Martin NA. A proposed grading system for arteriovenous malformations. J Neurosurg. 1986;65(4):476–83. https://doi.org/10.3171/jns.1986.65.4.0476 .
doi: 10.3171/jns.1986.65.4.0476 pubmed: 3760956
Hafazalla K, Baldassari MP, Sweid A, et al. A comparison of dual-lumen balloon and simple microcatheters in the embolization of DAVFs and AVMs using onyx. J Clin Neurosci. 2020;81:295–301. https://doi.org/10.1016/j.jocn.2020.10.007 .
doi: 10.1016/j.jocn.2020.10.007 pubmed: 33222933
Clarencon F, Shotar E, Pouvelle A, et al. Spinal epidural arteriovenous fistula embolization with ethylene vinyl alcohol (EVOH) copolymer using the Scepter Mini dual-lumen balloon. J Neurointerv Surg. 2021;13(5):492. https://doi.org/10.1136/neurintsurg-2020-016395 .
doi: 10.1136/neurintsurg-2020-016395 pubmed: 32859746
Pulli B, Sussman ES, Mayercik V, et al. Initial experience with the Scepter Mini dual-lumen balloon for transophthalmic artery embolization of anterior cranial fossa dural arteriovenous fistulae. J Neurointerv Surg. 2020;12(11):1132–6. https://doi.org/10.1136/neurintsurg-2020-016013 .
doi: 10.1136/neurintsurg-2020-016013 pubmed: 32434799
Vollherbst DF, Chapot R, Wallocha M, et al. First clinical multicenter experience with the new Scepter Mini microballoon catheter. J Neurointerv Surg. 2021;13(3):261–6. https://doi.org/10.1136/neurintsurg-2020-016115 .
doi: 10.1136/neurintsurg-2020-016115 pubmed: 32546639
White TG, Shah KA, Turpin J, et al. Single institution early clinical experience with the Scepter Mini balloon catheter. Neuroradiol J. 2021;34(6):562–7. https://doi.org/10.1177/19714009211013495 .
doi: 10.1177/19714009211013495 pubmed: 34014796 pmcid: 8649195
Mehta T, Hassan A, Masood K, et al. The next step in balloon assisted endovascular neurosurgical procedures: a case series of initial experience with the scepter mini balloon microcatheter. Interv Neuroradiol. 2021;27(2):298–306. https://doi.org/10.1177/1591019920972884 .
doi: 10.1177/1591019920972884 pubmed: 33164616
Al Raaisi A, Gabrieli J, Sourour NA, et al. Dual lumen balloon spontaneous inflation during embolization. Clin Neuroradiol. 2019;29(2):365–9. https://doi.org/10.1007/s00062-018-0716-y .
doi: 10.1007/s00062-018-0716-y pubmed: 30120490

Auteurs

Frédéric Clarençon (F)

Sorbonne University, Paris, France. frederic.clarencon@aphp.fr.
GRC BioFast, Sorbonne University, Paris, France. frederic.clarencon@aphp.fr.

Chrysanthi Papagiannaki (C)

Department of Radiology, Rouen University Hospital, Rouen, France.

Suzanna Saleme (S)

Department of Neuroradiology, Limoges University Hospital, Limoges, France.

Aymeric Rouchaud (A)

Department of Neuroradiology, Limoges University Hospital, Limoges, France.
University of Limoges, Limoges, France.

Eimad Shotar (E)

Department of Neuroradiology, Pitié-Salpêtrière Hospital, 47 Bd de l'Hôpital, 75013, Paris, France.

Emily Rius (E)

Department of Neuroradiology, Pitié-Salpêtrière Hospital, 47 Bd de l'Hôpital, 75013, Paris, France.

Julien Burel (J)

Department of Radiology, Rouen University Hospital, Rouen, France.

Anne-Laure Boch (AL)

Department of Neurosurgery, APHP-Sorbonne University, Paris, France.

Nader-Antoine Sourour (NA)

Department of Neuroradiology, Pitié-Salpêtrière Hospital, 47 Bd de l'Hôpital, 75013, Paris, France.

Charbel Mounayer (C)

Department of Neuroradiology, Limoges University Hospital, Limoges, France.
University of Limoges, Limoges, France.

Classifications MeSH