Biomechanical testing of osteosynthetic locking plates for proximal humeral shaft fractures - a systematic literature review.


Journal

Biomedizinische Technik. Biomedical engineering
ISSN: 1862-278X
Titre abrégé: Biomed Tech (Berl)
Pays: Germany
ID NLM: 1262533

Informations de publication

Date de publication:
15 Dec 2023
Historique:
received: 27 01 2023
accepted: 27 06 2023
medline: 23 11 2023
pubmed: 5 7 2023
entrez: 5 7 2023
Statut: epublish

Résumé

Proximal humeral shaft fractures can be treated with helically deformed bone plates to reduce the risk of iatrogenic nerve lesion. Controversially to this common surgical technique that was first established in 1999, no biomechanical investigation on humeral helical plating is recorded by other reviews, which focus on proximal fractures exclusively. Does an additional scope for shaft fractures reveal findings of helical testing? The present systematic literature review was performed based on guidelines by Kitchenham et al. to systematically search and synthesize literature regarding biomechanical testing of osteosynthetic systems for proximal humeral shaft fractures. Therefore, a systematic approach to search and screen literature was defined beforehand and applied on the findings of the database PubMed

Identifiants

pubmed: 37406349
pii: bmt-2023-0039
doi: 10.1515/bmt-2023-0039
doi:

Types de publication

Systematic Review Journal Article Review

Langues

eng

Sous-ensembles de citation

IM

Pagination

553-561

Informations de copyright

© 2023 Walter de Gruyter GmbH, Berlin/Boston.

Références

Rupp, M, Walter, N, Pfeifer, C. The incidence of fractures among the adult population of Germany–an analysis from 2009 through 2019. Dtsch Arztebl Int 2021;118:665–9. https://doi.org/10.3238/arztebl.m2021.0238 .
doi: 10.3238/arztebl.m2021.0238
Cronier, P, Pietu, G, Dujardin, C, Bigorre, N, Ducellier, F, Gerard, R. The concept of locking plates. Orthop Traumatol Surg Res 2010;96S:S17–36. https://doi.org/10.1016/j.otsr.2010.03.008 .
doi: 10.1016/j.otsr.2010.03.008
Kim, JW, Oh, C-W, Byun, Y-S, Kim, JJ, Park, KC. A prospective randomized study of operative treatment for noncomminuted humeral shaft fractures: conventional open plating versus minimal invasive plate osteosynthesis. J Orthop Trauma 2015;29:189–94. https://doi.org/10.1097/bot.0000000000000232 .
doi: 10.1097/bot.0000000000000232
Kettelkamp, DB, Alexander, H. Clinical review of radial nerve injury. J Trauma 1967;7:424–32. https://doi.org/10.1097/00005373-196705000-00007 .
doi: 10.1097/00005373-196705000-00007
Claessen, FMAP, Peters, RM, Verbeek, DO, Helfet, DL, Ring, D. Factors associated with radial nerve palsy after operative treatment of diaphyseal humeral shaft fractures. J Shoulder Elbow Surg 2015;24:e307–11. https://doi.org/10.1016/j.jse.2015.07.012 .
doi: 10.1016/j.jse.2015.07.012
Schwab, TR, Stillhard, PF, Schibli, S, Furrer, M, Sommer, C. Radial nerve palsy in humeral shaft fractures with internal fixation: analysis of management and outcome. Eur J Trauma Emerg Surg 2018;44:235–43. https://doi.org/10.1007/s00068-017-0775-9 .
doi: 10.1007/s00068-017-0775-9
van de Wall, BJM, Ganzert, C, Theus, C. Results of plate fixation for humerus fractures in a large single-center cohort. Arch Orthop Trauma Surg 2020;140:1311–8. https://doi.org/10.1007/s00402-019-03319-z .
doi: 10.1007/s00402-019-03319-z
Da Silva, T, Rummel, F, Knop, C, Merkle, T. Comparing iatrogenic radial nerve lesions in humeral shaft fractures treated with helical or straight PHILOS plates: a 10-year retrospective cohort study of 62 cases. Arch Orthop Trauma Surg 2020;140:1931–7. https://doi.org/10.1007/s00402-020-03438-y .
doi: 10.1007/s00402-020-03438-y
Moon, J-G, Kwon, H-N, Biraris, S, Shon, W-Y. Minimally invasive plate osteosynthesis using a helical plate for metadiaphyseal complex fractures of the proximal humerus. Orthopedics 2014;37:e237–43. https://doi.org/10.3928/01477447-20140225-55 .
doi: 10.3928/01477447-20140225-55
Tan, JCH, Kagda, FHY, Murphy, D, Thambiah, JS, Khong, KS. Minimally invasive helical plating for shaft of humerus fractures: technique and outcome. Open Orthop J 2012;6:184–8. https://doi.org/10.2174/1874325001206010184 .
doi: 10.2174/1874325001206010184
Wang, Q, Hu, J, Guan, J, Chen, Y, Wang, L. Proximal third humeral shaft fractures fixed with long helical PHILOS plates in elderly patients: benefit of pre-contouring plates on a 3D-printed model-a retrospective study. J Orthop Surg Res 2018;13:203. https://doi.org/10.1186/s13018-018-0908-9 .
doi: 10.1186/s13018-018-0908-9
Gill, DR, Torchia, ME. The spiral compression plate for proximal humeral shaft nonunion: a case report and description of a new technique. J Orthop Trauma 1999;13:141–4. https://doi.org/10.1097/00005131-199902000-00013 .
doi: 10.1097/00005131-199902000-00013
Jabran, A, Peach, C, Ren, L. Biomechanical analysis of plate systems for proximal humerus fractures: a systematic literature review. Biomed Eng Online 2018;17:47. https://doi.org/10.1186/s12938-018-0479-3 .
doi: 10.1186/s12938-018-0479-3
Cruickshank, D, Lefaivre, KA, Johal, H. A scoping review of biomechanical testing for proximal humerus fracture implants. BMC Muscoskel Disord 2015;16:175. https://doi.org/10.1186/s12891-015-0627-x .
doi: 10.1186/s12891-015-0627-x
Kitchenham, B. Procedures for performing systematic reviews . Keele University Technical; 2004. Report TR/SE-0401 and NICTA Technical Report 0400011T.1.
Meinberg, EG, Agel, J, Roberts, CS, Karam, MD, Kellam, JF. Fracture and dislocation classification compendium-2018. J Orthop Trauma 2018;32:S1–S170. https://doi.org/10.1097/bot.0000000000001063 .
doi: 10.1097/bot.0000000000001063
Bergmann, G, Graichen, F, Bender, A, Kääb, M, Rohlmann, A, Westerhoff, P. In vivo glenohumeral contact forces--measurements in the first patient 7 months postoperatively. J Biomech 2007;40:2139–49. https://doi.org/10.1016/j.jbiomech.2006.10.037 .
doi: 10.1016/j.jbiomech.2006.10.037
Bergmann, G, Graichen, F, Bender, A. In vivo gleno-humeral joint loads during forward flexion and abduction. J Biomech 2011;44:1543–52. https://doi.org/10.1016/j.jbiomech.2011.02.142 .
doi: 10.1016/j.jbiomech.2011.02.142
Westerhoff, P, Graichen, F, Bender, A. In vivo measurement of shoulder joint loads during activities of daily living. J Biomech 2009;42:1840–9. https://doi.org/10.1016/j.jbiomech.2009.05.035 .
doi: 10.1016/j.jbiomech.2009.05.035
Aksakal, B, Gurger, M, Say, Y, Yilmaz, E. Biomechanical comparison of straight DCP and helical plates for fixation of transverse and oblique bone fractures. Acta Bioeng Biomech 2014;16:67–74.
Acklin, YP, Zderic, I, Inzana, JA. Biomechanical evaluation of a new gliding screw concept for the fixation of proximal humeral fractures. Bone Joint Res 2018;7:422–9. https://doi.org/10.1302/2046-3758.76.bjr-2017-0356.r1 .
doi: 10.1302/2046-3758.76.bjr-2017-0356.r1
Katthagen, JC, Schwarze, M, Meyer-Kobbe, J, Voigt, C, Hurschler, C, Lill, H. Biomechanical effects of calcar screws and bone block augmentation on medial support in locked plating of proximal humeral fractures. Clin Biomech 2014;29:735–41. https://doi.org/10.1016/j.clinbiomech.2014.06.008 .
doi: 10.1016/j.clinbiomech.2014.06.008
Katthagen, JC, Schwarze, M, Warnhoff, M, Voigt, C, Hurschler, C, Lill, H. Influence of plate material and screw design on stiffness and ultimate load of locked plating in osteoporotic proximal humeral fractures. Injury 2016;47:617–24. https://doi.org/10.1016/j.injury.2016.01.004 .
doi: 10.1016/j.injury.2016.01.004
Kim, H, Shin, MJ, Kholinne, E. How many proximal screws are needed for a stable proximal humerus fracture fixation? Geriatr Orthop Surg Rehabil 2021;12:1–8. https://doi.org/10.1177/2151459321992744 .
doi: 10.1177/2151459321992744
Shin, MJ, Kim, H, Kim, DM, Park, D, Jeon, I-H, Koh, KH. Role of inferomedial supporting screws for secondary varus deformity in non-osteoporotic proximal humerus fracture: a biomechanical study. Arch Orthop Trauma Surg 2021;141:1517–23. https://doi.org/10.1007/s00402-020-03627-9 .
doi: 10.1007/s00402-020-03627-9
Tilton, M, Armstrong, A, Sanville, J. Biomechanical testing of additive manufactured proximal humerus fracture fixation plates. Ann Biomed Eng 2020;48:463–76. https://doi.org/10.1007/s10439-019-02365-3 .
doi: 10.1007/s10439-019-02365-3
Yoon, RS, Dziadosz, D, Porter, DA, Frank, MA, Smith, WR, Liporace, FA. A comprehensive update on current fixation options for two-part proximal humerus fractures: a biomechanical investigation. Injury 2014;45:510–4. https://doi.org/10.1016/j.injury.2013.08.024 .
doi: 10.1016/j.injury.2013.08.024
Ahmad, M, Nanda, R, Bajwa, AS, Candal-Couto, J, Green, S, Hui, AC. Biomechanical testing of the locking compression plate: when does the distance between bone and implant significantly reduce construct stability? Injury 2007;38:358–64. https://doi.org/10.1016/j.injury.2006.08.058 .
doi: 10.1016/j.injury.2006.08.058
Al-Jahwari, A, Schemitsch, EH, Wunder, JS, Ferguson, PC, Zdero, R. The biomechanical effect of torsion on humeral shaft repair techniques for completed pathological fractures. J Biomech Eng 2012;134:1–7. https://doi.org/10.1115/1.4005696 .
doi: 10.1115/1.4005696
Becker, EH, Kim, H, Shorofsky, M, Hsieh, AH, Watson, JD, OʼToole, RV. Biomechanical comparison of cadaveric and commercially available synthetic osteoporotic bone analogues in a locked plate fracture model under torsional loading. J Orthop Trauma 2017;31:e137–42. https://doi.org/10.1097/bot.0000000000000782 .
doi: 10.1097/bot.0000000000000782
Dankl, L, Schmoelz, W, Hoermann, R, Euler, S. Evaluation of mushroom-shaped allograft for unstable proximal humerus fractures. Arch Orthop Trauma Surg 2022;142:409–16. https://doi.org/10.1007/s00402-020-03715-w .
doi: 10.1007/s00402-020-03715-w
Di Tullio, PO, Giordano, V, Souto, E. Biomechanical behavior of three types of fixation in the two-part proximal humerus fracture without medial cortical support. PLoS One 2019;14:1–12. https://doi.org/10.1371/journal.pone.0220523 .
doi: 10.1371/journal.pone.0220523
Hessmann, MH, Hansen, WSM, Krummenauer, F, Pol, TF, Rommens, PM. Locked plate fixation and intramedullary nailing for proximal humerus fractures: a biomechanical evaluation. J Trauma 2005;58:1194–201. https://doi.org/10.1097/01.ta.0000170400.68994.ab .
doi: 10.1097/01.ta.0000170400.68994.ab
Röderer, G, Scola, A, Schmölz, W, Gebhard, F, Windolf, M, Hofmann-Fliri, L. Biomechanical in vitro assessment of screw augmentation in locked plating of proximal humerus fractures. Injury 2013;44:1327–32. https://doi.org/10.1016/j.injury.2013.05.008 .
doi: 10.1016/j.injury.2013.05.008
Sandmann, G, Ateschrang, A, Freude, T. Dynamic locking screws in proximal humeral plate osteosynthesis demonstrate superior fixation properties: a biomechanical study. J Exp Orthop 2020;7:82 1–8. https://doi.org/10.1186/s40634-020-00293-z .
doi: 10.1186/s40634-020-00293-z
Seide, K, Triebe, J, Faschingbauer, M. Locked vs. unlocked plate osteosynthesis of the proximal humerus – a biomechanical study. Clin Biomech 2007;22:176–82. https://doi.org/10.1016/j.clinbiomech.2006.08.009 .
doi: 10.1016/j.clinbiomech.2006.08.009
Siffri, PC, Peindl, RD, Coley, ER, Norton, J, Connor, PM, Kellam, JF. Biomechanical analysis of blade plate versus locking plate fixation for a proximal humerus fracture: comparison using cadaveric and synthetic humeri. J Orthop Trauma 2006;20:547–54. https://doi.org/10.1097/01.bot.0000244997.52751.58 .
doi: 10.1097/01.bot.0000244997.52751.58
Theopold, J, Schleifenbaum, S, Müller, M. Biomechanical evaluation of hybrid double plate osteosynthesis using a locking plate and an inverted third tubular plate for the treatment of proximal humeral fractures. PLoS One 2018;13:1–13. https://doi.org/10.1371/journal.pone.0206349 .
doi: 10.1371/journal.pone.0206349
Zettl, R, Müller, T, Topp, T. Monoaxial versus polyaxial locking systems: a biomechanical analysis of different locking systems for the fixation of proximal humeral fractures. Int Orthop 2011;35:1245–50. https://doi.org/10.1007/s00264-011-1220-z .
doi: 10.1007/s00264-011-1220-z
Zhang, X, Huang, J, Zhao, L. Inferomedial cortical bone contact and fixation with calcar screws on the dynamic and static mechanical stability of proximal humerus fractures. J Orthop Surg Res 2019;14:1. https://doi.org/10.1186/s13018-018-1031-7 .
doi: 10.1186/s13018-018-1031-7
Zheng, Y-F, Zhou, J-L, Wang, X-H, Shan, L, Liu, Y. Biomechanical study of the fixation strength of anteromedial plating for humeral shaft fractures. Chin Med J 2016;129:1850–5. https://doi.org/10.4103/0366-6999.186645 .
doi: 10.4103/0366-6999.186645

Auteurs

Christian Halbauer (C)

Department of Mechatronics and Medical Engineering, Biomechatronics Research Group, Ulm, University of Applied Sciences, Ulm, Germany.

Felix Capanni (F)

Department of Mechatronics and Medical Engineering, Biomechatronics Research Group, Ulm, University of Applied Sciences, Ulm, Germany.

Isabel Bertusch (I)

Department of Mechatronics and Medical Engineering, Biomechatronics Research Group, Ulm, University of Applied Sciences, Ulm, Germany.

Andreas Paech (A)

Department for Orthopedic and Trauma Surgery, University Medical Center Schleswig-Holstein, Lübeck, Germany.

Tobias Merkle (T)

Department of Trauma Surgery and Orthopedics, Clinical Centre Stuttgart-Katharinenhospital, Stuttgart, Germany.

Tomas Da Silva (T)

Department of Trauma Surgery and Orthopedics, Clinical Centre Stuttgart-Katharinenhospital, Stuttgart, Germany.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH