PLCL-TPU bi-layered artificial blood vessel with compliance matching to host vessel.

Artificial blood vessel compliance dip-coating electrospinning hemodynamics

Journal

Journal of biomaterials applications
ISSN: 1530-8022
Titre abrégé: J Biomater Appl
Pays: England
ID NLM: 8813912

Informations de publication

Date de publication:
08 2023
Historique:
medline: 8 8 2023
pubmed: 6 7 2023
entrez: 6 7 2023
Statut: ppublish

Résumé

Compliance mismatch between the artificial blood vessel and the host vessel leads to abnormal hemodynamics and is a major mechanical trigger of intimal hyperplasia. Efforts have been made to achieve higher compliance of artificial blood vessels. However, the preparation of artificial blood vessels with compliance matching to host vessels has not been realized. A bi-layered artificial blood vessel was successfully prepared by dip-coating and electrospinning composite method using poly(L-Lactide-co-caprolactone) (PLCL) and thermoplastic poly(ether urethane) (TPU). In the case of a certain wall thickness (200 μm), thickness ratios of the PLCL inner layer (dip-coating method) and TPU outer layer (electrospinning method) were controlled at 0:1, 1:9, 3:7, 5:5, 7:3, and 1:0 respectively and the compliance, radial tensile properties, burst pressure, and suture retention strength were investigated. Results showed compliance value of the artificial blood vessel decreased with the increase of the thickness ratio, which suggested the compliance of the bi-layered artificial blood vessel can be regulated by adjusting the ratio of the inner and outer layer thicknesses. In the six different artificial blood vessels, the one with thickness ratio of 1:9 not only had high compliance (8.768 ± 0.393%/100 mmHg) but also can guarantee the other mechanical properties, such as the radial breaking strength (6.333 ± 0.689 N/mm), burst pressure (534.473 ± 20.899 mmHg), and suture retention strength (300.773 ± 9.351 cN). The proposed artificial blood vessel preparation method is expected to achieve compliance matching with the host vessel. It is beneficial for eliminating abnormal hemodynamics and reducing intimal hyperplasia.

Identifiants

pubmed: 37408454
doi: 10.1177/08853282231188424
doi:

Substances chimiques

Blood Substitutes 0
Polyesters 0

Types de publication

Journal Article Research Support, Non-U.S. Gov't

Langues

eng

Sous-ensembles de citation

IM

Pagination

194-202

Auteurs

Lihua Guan (L)

Soochow University, Suzhou, China.

Huijing Zhao (H)

Soochow University, Suzhou, China.

Kai Wang (K)

Nankai University, Tianjin, China.

Ke-Qin Zhang (KQ)

Soochow University, Suzhou, China.

Kai Meng (K)

Soochow University, Suzhou, China.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH