Résumé

The z-spectrum contains many pools with different exchange rates and T

Identifiants

pubmed: 37452522
doi: 10.1002/nbm.5001
doi:

Substances chimiques

Creatine MU72812GK0

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

e5001

Subventions

Organisme : Haydn Green Foundation

Informations de copyright

© 2023 The Authors. NMR in Biomedicine published by John Wiley & Sons Ltd.

Références

Zhou J, Payen JF, Wilson DA, Traystman RJ, Van Zijl PCM. Using the amide proton signals of intracellular proteins and peptides to detect pH effects in MRI. Nat Med. 2003;9(8):1085-1090. doi:10.1038/nm907
Zaiss M, Zu Z, Xu J, et al. A combined analytical solution for chemical exchange saturation transfer and semi-solid magnetization transfer. NMR Biomed. 2015;28(2):217-230. doi:10.1002/nbm.3237
Zaiss M, Xu J, Goerke S, et al. Inverse Z-spectrum analysis for spillover-, MT-, and T1-corrected steady-state pulsed CEST-MRI-application to pH-weighted MRI of acute stroke. NMR Biomed. 2014;27(3):240-252. doi:10.1002/nbm.3054
Zaiss M, Bachert P. Chemical exchange saturation transfer (CEST) and MR Z-spectroscopy in vivo: a review of theoretical approaches and methods. Phys Med Biol. 2013;58(22):R221-R269. doi:10.1088/0031-9155/58/22/R221
McMahon MT, Gilad AA, Zhou J, Sun PZ, Bulte JWM, Van Zijl PCM. Quantifying exchange rates in chemical exchange saturation transfer agents using the saturation time and saturation power dependencies of the magnetization transfer effect on the magnetic resonance imaging signal (QUEST and QUESP): pH calibration for poly. Magn Reson Med. 2006;55(4):836-847. doi:10.1002/mrm.20818
Zaiss M, Angelovski G, Demetriou E, McMahon MT, Golay X, Scheffler K. QUESP and QUEST revisited-fast and accurate quantitative CEST experiments. Magn Reson Med. 2018;79(3):1708-1721. doi:10.1002/mrm.26813
Kim B, Schär M, Park HW, Heo HY. A deep learning approach for magnetization transfer contrast MR fingerprinting and chemical exchange saturation transfer imaging. Neuroimage. 2020;221:117165. doi:10.1016/j.neuroimage.2020.117165
Heo HY, Han Z, Jiang S, Schär M, van Zijl PCM, Zhou J. Quantifying amide proton exchange rate and concentration in chemical exchange saturation transfer imaging of the human brain. Neuroimage. 2019;189:202-213. doi:10.1016/j.neuroimage.2019.01.034
Geades N, Hunt BAEE, Shah SM, Peters A, Mougin OE, Gowland PA. Quantitative analysis of the z-spectrum using a numerically simulated look-up table: application to the healthy human brain at 7T. Magn Reson Med. 2017;78(2):645-655. doi:10.1002/mrm.26459
Chappell MA, Donahue MJ, Tee YK, et al. Quantitative Bayesian model-based analysis of amide proton transfer MRI. Magn Reson Med. 2013;70(2):556-567. doi:10.1002/mrm.24474
Eberhart R, Kennedy J. New optimizer using particle swarm theory. In: Proceedings of the International Symposium on Micro Machine and Human Science; 1995. doi:10.1109/mhs.1995.494215
Shi Y, Eberhart R. Modified particle swarm optimizer. In: Proceedings of the IEEE Conference on Evolutionary Computation, ICEC; 1998. doi:10.1109/icec.1998.699146
Poli R. Analysis of the publications on the applications of particle swarm optimisation. J Artif Evol Appl. 2008;2008:1-10. doi:10.1155/2008/685175
Hassan R, Cohanim B, De Weck O, et al. A Comparison of Particle Swarm. American Institute of Aeronautics and Astronautics; 2004.
Zaiss M, Bachert P. Exchange-dependent relaxation in the rotating frame for slow and intermediate exchange-modeling off-resonant spin-lock and chemical exchange saturation transfer. NMR Biomed. 2013;26(5):507-518. doi:10.1002/nbm.2887
Stanisz GJ, Odrobina EE, Pun J, et al. T1, T2 relaxation and magnetization transfer in tissue at 3T. Magn Reson Med. 2005;54(3):507-512. doi:10.1002/mrm.20605
Haris M, Singh A, Cai K, et al. A technique for in vivo mapping of myocardial creatine kinase metabolism. Nat Med. 2014;20(2):209-214. doi:10.1038/nm.3436
Sun PZ, Xiao G, Zhou IY, Guo Y, Wu R. A method for accurate pH mapping with chemical exchange saturation transfer (CEST) MRI. Contrast Media Mol Imaging. 2016;11(3):195-202. doi:10.1002/cmmi.1680
Hoogduin H, Khlebnikov V, Keupp J, et al. Semi continuous wave CEST with alternating sets of 4 transmit channels at 7T. MAGMA. 2017;30(Suppl 1):S1-S152. doi:10.1002/nbm.3687
MathWorks, Inc. MATLAB, version 9.6. Published online 2019. www.mathworks.com/products/matlab
Shah SM, Mougin OE, Carradus AJ, et al. The z-spectrum from human blood at 7T. Neuroimage. 2018;167:31-40. doi:10.1016/j.neuroimage.2017.10.053
Greene DJ, Koller JM, Hampton JM, et al. Behavioral interventions for reducing head motion during MRI scans in children. Neuroimage. 2018;171:234-245. doi:10.1016/J.NEUROIMAGE.2018.01.023
Mougin O, Abdel-Fahim R, Dineen R, Pitiot A, Evangelou N, Gowland P. Imaging gray matter with concomitant null point imaging from the phase sensitive inversion recovery sequence. Magn Reson Med. 2016;76(5):1512-1516. doi:10.1002/mrm.26061
FAST-FslWiki. Accessed April 12, 2022. https://fsl.fmrib.ox.ac.uk/fsl/fslwiki/FAST
MCFLIRT-FslWiki. Accessed April 12, 2022. https://fsl.fmrib.ox.ac.uk/fsl/fslwiki/MCFLIRT
Zhang XY, Wang F, Afzal A, et al. A new NOE-mediated MT signal at around -1.6 ppm for detecting ischemic stroke in rat brain. Magn Reson Imaging. 2016;34(8):1100-1106. doi:10.1016/J.MRI.2016.05.002
Tee YK, Khrapitchev AA, Sibson NR, Payne SJ, Chappell MA. Evaluating the use of a continuous approximation for model-based quantification of pulsed chemical exchange saturation transfer (CEST). J Magn Reson. 2012;222(3):88-95. doi:10.1016/j.jmr.2012.07.003
Goerke S, Zaiss M, Bachert P. Characterization of creatine guanidinium proton exchange by water-exchange (WEX) spectroscopy for absolute-pH CEST imaging in vitro. NMR Biomed. 2014;27(5):507-518. doi:10.1002/NBM.3086
Yao J, Wang C, Ellingson BM. Influence of phosphate concentration on amine, amide, and hydroxyl CEST contrast. Magn Reson Med. 2021;85(2):1062-1078. doi:10.1002/mrm.28481
Lee JS, Regatte RR, Jerschow A. Bloch equations for proton exchange reactions in an aqueous solution. Concepts Magn Reson Part A Bridg Educ Res. 2016;45A(3):e21397. doi:10.1002/CMR.A.21397
Tsukiashi A, Min KS, Kitayama H, et al. Application of spin-crossover water soluble nanoparticles for use as MRI contrast agents. Sci Rep. 2018;8(1):1-5. doi:10.1038/s41598-018-33362-6
Liu D, Zhou J, Xue R, Zuo Z, An J, Wang DJJ. Quantitative characterization of nuclear Overhauser enhancement and amide proton transfer effects in the human brain at 7 Tesla. Magn Reson Med. 2013;70(4):1070-1081. doi:10.1002/mrm.24560
Wang Z, Shaghaghi M, Zhang S, et al. Novel proton exchange rate MRI presents unique contrast in brains of ischemic stroke patients. J Neurosci Methods. 2020;346:108926. doi:10.1016/j.jneumeth.2020.108926
Mougin O, Coxon R, Pitiot A, Gowland P. Magnetization transfer phenomenon in the human brain at 7 T. Neuroimage. 2010;49(1):272-281. doi:10.1016/j.neuroimage.2009.08.022
Ropele S, Seifert T, Enzinger C, Fazekas F. Method for quantitative imaging of the macromolecular 1H fraction in tissues. Magn Reson Med. 2003;49(5):864-871. doi:10.1002/mrm.10427
Dortch RD, Moore J, Li K, et al. Quantitative magnetization transfer imaging of human brain at 7T. Neuroimage. 2013;64:640-649. doi:10.1016/j.neuroimage.2012.08.047
Mckeithan LJ, Lyttle BD, Box BA, et al. 7T quantitative magnetization transfer (qMT) of cortical gray matter in multiple sclerosis correlates with cognitive impairment. Neuroimage. 2019;203:116190. doi:10.1016/j.neuroimage.2019.116190
Zu Z. Ratiometric NOE(−1.6) contrast in brain tumors. NMR Biomed. 2018;31(12):e4017. doi:10.1002/nbm.4017
Desmond KL, Moosvi F, Stanisz GJ. Mapping of amide, amine, and aliphatic peaks in the CEST spectra of murine xenografts at 7 T. Magn Reson Med. 2014;71(5):1841-1853. doi:10.1002/mrm.24822
Sui R, Chen L, Li Y, Huang J, et al. Whole-brain amide CEST imaging at 3T with a steady-state radial MRI acquisition. Magn Reson Med. 2021;86(2):893-906. doi:10.1002/mrm.28770
Schmitz-Abecassis B, Vinogradov E, Wijnen JP, et al. The use of variable delay multipulse chemical exchange saturation transfer for separately assessing different CEST pools in the human brain at 7T. Magn Reson Med. 2022;87(2):872-883. doi:10.1002/MRM.29005
Haris M, Nanga RPR, Singh A, et al. Exchange rates of creatine kinase metabolites: feasibility of imaging creatine by chemical exchange saturation transfer MRI. NMR Biomed. 2012;25(11):1305-1309. doi:10.1002/NBM.2792
Xu J, Chung JJ, Jin T. Chemical exchange saturation transfer imaging of creatine, phosphocreatine, and protein arginine residue in tissues. NMR Biomed. 2022;36(6):e4671. doi:10.1002/NBM.4671
Jin T, Kim SG. In vivo saturation transfer imaging of nuclear Overhauser effect from aromatic and aliphatic protons: implication to APT quantification. Proc Intl Soc Mag Reson Med. 2012;205(2):1579. doi:10.1002/mrm.24315
Xu J, Chan KWY, Xu X, Yadav N, Liu G, van Zijl PCM. On-resonance variable delay multipulse scheme for imaging of fast-exchanging protons and semisolid macromolecules. Magn Reson Med. 2017;77(2):730-739. doi:10.1002/mrm.26165

Auteurs

Andrew J Carradus (AJ)

Sir Peter Mansfield Imaging Centre and NIHR Nottingham Biomedical Research Centre, Nottingham University Hospitals NHS Trust, School of Physics and Astronomy, University of Nottingham, Nottingham, UK.

Joe M P Bradley (JMP)

Sir Peter Mansfield Imaging Centre and NIHR Nottingham Biomedical Research Centre, Nottingham University Hospitals NHS Trust, School of Physics and Astronomy, University of Nottingham, Nottingham, UK.

Penny A Gowland (PA)

Sir Peter Mansfield Imaging Centre and NIHR Nottingham Biomedical Research Centre, Nottingham University Hospitals NHS Trust, School of Physics and Astronomy, University of Nottingham, Nottingham, UK.

Olivier E Mougin (OE)

Sir Peter Mansfield Imaging Centre and NIHR Nottingham Biomedical Research Centre, Nottingham University Hospitals NHS Trust, School of Physics and Astronomy, University of Nottingham, Nottingham, UK.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH