Ultrathin bioresorbable polymer sirolimus-eluting stents in US patients undergoing coronary revascularization: 1-Year outcomes from the BIOFLOW VII trial.


Journal

Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions
ISSN: 1522-726X
Titre abrégé: Catheter Cardiovasc Interv
Pays: United States
ID NLM: 100884139

Informations de publication

Date de publication:
09 2023
Historique:
revised: 23 05 2023
received: 22 02 2023
accepted: 11 07 2023
medline: 12 9 2023
pubmed: 26 7 2023
entrez: 26 7 2023
Statut: ppublish

Résumé

Ultrathin strut coronary drug-eluting stents (DES) have demonstrated improved safety and efficacy in large contemporary trials. The evaluation of an ultrathin strut DES in a post-market United States (US) patient population was undertaken. The purpose of this post-approval study is to confirm that the clinical performance of an ultrathin strut bioresorbable polymer sirolimus-eluting stent (BP SES) in clinical practice is similar to that observed with BP SES in the BIOFLOW V pivotal trial. BIOFLOW VII is a prospective, multicenter, single-arm US post-market approval study to confirm the clinical performance of BP SES in a real-world setting. The primary endpoint of 1-year target lesion failure (TLF) was compared with a performance goal of 6.9% based on an adapted BIOFLOW V trial BP SES TLF rate and TLF rates from other US market-released DES utilizing the Society for Cardiovascular Angiography and Interventions definition for peri-procedural myocardial infarction (MI). Subjects undergoing percutaneous coronary intervention with BP SES were consented within 24 h post-index procedure with planned follow-up through 5 years. Among 556 enrolled patients, clinical demographics included: 34.7% female, 35.6% with diabetes mellitus, and 56.8% with acute coronary syndromes. The average stent length (mean ± standard deviation) was 20.2 ± 11.8 mm, and the mean number of stents per patient was 1.3 ± 0.6. Procedure success was 99.1% (551/556), and device success was 99.9% (689/690). Among 531 subjects included in the primary endpoint analysis, the 1-year rate of TLF rate was 1.7% (9/531), and the primary endpoint was met compared with the performance goal (p < 0.0001, 95% confidence interval: 0.69%, 3.43%). Rates of target vessel MI and clinically driven target lesion revascularization were 1.3% (7/531) and 0.9% (5/531), with no occurrence of cardiac death. Definite stent thrombosis was observed for two cases (0.4%; 2/556) with one acute (≤24 h) and one late (>30 days and ≤1 year) event. In a post-approval study, 1-year clinical outcomes with BP SES were consistent with prior trials supporting the safety and effectiveness of ultrathin BP SES.

Sections du résumé

BACKGROUND
Ultrathin strut coronary drug-eluting stents (DES) have demonstrated improved safety and efficacy in large contemporary trials. The evaluation of an ultrathin strut DES in a post-market United States (US) patient population was undertaken.
OBJECTIVE
The purpose of this post-approval study is to confirm that the clinical performance of an ultrathin strut bioresorbable polymer sirolimus-eluting stent (BP SES) in clinical practice is similar to that observed with BP SES in the BIOFLOW V pivotal trial.
METHODS
BIOFLOW VII is a prospective, multicenter, single-arm US post-market approval study to confirm the clinical performance of BP SES in a real-world setting. The primary endpoint of 1-year target lesion failure (TLF) was compared with a performance goal of 6.9% based on an adapted BIOFLOW V trial BP SES TLF rate and TLF rates from other US market-released DES utilizing the Society for Cardiovascular Angiography and Interventions definition for peri-procedural myocardial infarction (MI). Subjects undergoing percutaneous coronary intervention with BP SES were consented within 24 h post-index procedure with planned follow-up through 5 years.
RESULTS
Among 556 enrolled patients, clinical demographics included: 34.7% female, 35.6% with diabetes mellitus, and 56.8% with acute coronary syndromes. The average stent length (mean ± standard deviation) was 20.2 ± 11.8 mm, and the mean number of stents per patient was 1.3 ± 0.6. Procedure success was 99.1% (551/556), and device success was 99.9% (689/690). Among 531 subjects included in the primary endpoint analysis, the 1-year rate of TLF rate was 1.7% (9/531), and the primary endpoint was met compared with the performance goal (p < 0.0001, 95% confidence interval: 0.69%, 3.43%). Rates of target vessel MI and clinically driven target lesion revascularization were 1.3% (7/531) and 0.9% (5/531), with no occurrence of cardiac death. Definite stent thrombosis was observed for two cases (0.4%; 2/556) with one acute (≤24 h) and one late (>30 days and ≤1 year) event.
CONCLUSION
In a post-approval study, 1-year clinical outcomes with BP SES were consistent with prior trials supporting the safety and effectiveness of ultrathin BP SES.

Identifiants

pubmed: 37493431
doi: 10.1002/ccd.30783
doi:

Substances chimiques

Sirolimus W36ZG6FT64
Everolimus 9HW64Q8G6G
Polymers 0

Types de publication

Multicenter Study Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

464-471

Subventions

Organisme : Biotronik

Informations de copyright

© 2023 Wiley Periodicals LLC.

Références

Kandzari DE, Mauri L, Koolen JJ, et al. Ultrathin, bioresorbable polymer sirolimus-eluting stents versus thin, durable polymer everolimus-eluting stents in patients undergoing coronary revascularisation (BIOFLOW V): a randomised trial. Lancet. 2017;390:1843-1852.
Kandzari DE, Koolen JJ, Doros G, et al. Ultrathin bioresorbable polymer sirolimus-eluting stents versus thin durable polymer everolimus-eluting stents. JACC. 2018;72(25):3287-3297.
Kandzari DE, Koolen JJ, Doros G, et al. Ultrathin bioresorbable-polymer sirolimus-eluting stents versus thin durable-polymer everolimus-eluting stents for coronary revascularization: 3-year outcomes from the randomized BIOFLOW V trial. JACC Cardiovasc Interv. 2020;13(11):1343-1353.
Kandzari DE, Koolen JJ, Doros G, et al. Ultrathin bioresorbable polymer sirolimus-eluting stents versus durable polymer everolimus-eluting stents: BIOFLOW V final 5-year outcomes. JACC Cardiovasc Interv. 2022;15(18):1852-1860.
Iglesias JF, Muller O, Heg D, et al. Biodegradable polymer sirolimus-eluting stents versus durable polymer everolimus-eluting stents in patients with ST-segment elevation myocardial infarction (BIOSTEMI): a single-blind, prospective, randomised superiority trial. Lancet. 2019;394:1243-1253.
Jensen LO, Maeng M, Raungaard B, et al. SORT OUT IX Study Group Randomized comparison of the polymer-free biolimus-coated Biofreedom stent with the ultrathin strut biodegradable polymer sirolimus-eluting Orsiro stent in an all-comers population treated with percutaneous coronary intervention: the SORT OUT IX trial. Circulation. 2020;141:2052-2063.
Jakobsen L, Christiansen EH, Freeman P, et al. Randomized clinical comparison of the dual-therapy CD34 antibody-covered sirolimus-eluting Combo stent with the sirolimus-eluting Orsiro stent in patients treated with percutaneous coronary intervention: the SORT OUT X trial. Circulation. 2021;143:2155-2165.
Bangalore S, Toklu B, Patel N, Feit F, Stone GW. Newer-generation ultrathin strut drug-eluting stents versus older second-generation thicker strut drug-eluting stents for coronary artery disease: meta-analysis of randomized trials. Circulation. 2018;138:2216-2226.
Madhavan MV, Howard JP, Naqvi A, et al. Long-term follow-up after ultrathin vs. conventional 2nd-generation drug-eluting stents: a systematic review and meta-analysis of randomized controlled trials. Eur Heart J. 2021;42:2643-2654.
Taglieri N, Bruno AG, Ghetti G, et al. Target lesion failure with current drug-eluting stents. JACC Cardiovasc Interv. 2020;13:2868-2878.
Kandzari DE, Smits PC, Love MP, et al. Randomized comparison of ridaforolimus- and zotarolimus-eluting coronary stents in patients with coronary artery disease. Primary results from the BIONICS trial (BioNIR Ridaforolimus-Eluting Coronary Stent System in Coronary Stenosis). Circulation. 2017;136:1304-1314.
Levine GN, Bates ER, Bittl JA, et al. ACC/AHA guideline focused update on duration of dual antiplatelet therapy in patients with coronary artery disease. A report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines. Circulation. 2016;2016(134):e123-e155.
Cutlip DE, Windecker S, Mehran R, et al. Clinical end points in coronary stent trials: a case for standardized definitions. Circulation. 2007;115:2344-2351.
Moussa ID, Klein LW, Shah B, et al. Consideration of a new definition of clinically relevant myocardial infarction after coronary revascularization. JACC. 2013;62(17):1563-1570.
Ellert-Gregersen J, Jensen LJ, Jakobsen L, et al. Polymer-free biolimus-coated stents versus ultrathin-strut biodegradable polymer sirolimus-eluting stents: two-year outcomes of the randomised SORT OUT IX trial. EuroIntervention. 2022;18:e124-e131. doi:10.4244/EIJ-D-21-00874
Pilgrim T, Muller O, Heg D, et al. Biodegradable- versus durable-polymer drug-eluting stents for STEMI. JACC Cardiovasc Interv. 2021;14:639-648.
Yoon CH, Kwun JS, Choi YJ, et al. Biomatrix versus Orsiro stents for coronary artery disease; a multicenter, randomized, open-label study. Circ Cardiovasc Interv. 2023;16:e012307.
Buccheri S, Sarno G, Erlinge D, et al. Clinical outcomes with unselected use of an ultrathin-strut sirolimus-eluting stent: a report from the Swedish Coronary Angiography and Angioplasty Registry (SCAAR). Eurointervention. 2021;16:1413-1421.
Kolandaivelu K, Swaminathan R, Gibson WJ, et al. Stent thrombogenicity early in high-risk interventional settings is driven by stent design and deployment and protected by polymer-drug coatings. Circulation. 2011;123:1400-1409.
Soucy N, Feygin J, Tunstall R, et al. Strut tissue coverage and endothelial cell coverage: a comparison between bare metal stent platforms and platinum chromium stents with and without everolimus-eluting coating. EuroIntervention. 2010;6:630-637.
Kastrati A, Mehilli J, Dirschinger J, et al. Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO) trial. Circulation. 2001;103:2816-2821.
Pache Jü, Kastrati A, Mehilli J, et al. Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO-2) trial. JACC. 2003;41:1283-1288.
Nakazawa G, Otsuka F, Nakano M, et al. The pathology of neoatherosclerosis in human coronary implants. JACC. 2011;57:1314-1322.
Kuriyama N, Kobayashi Y, Nakama T, et al. Late restenosis following sirolimus-eluting stent implantation. JACC Cardiovasc Interv. 2011;4:123-128.
Koppara T, Joner M, Bayer G, Steigerwald K, Diener T, Wittchow E. Histopathological comparison of biodegradable polymer and permanent polymer based sirolimus eluting stents in a porcine model of coronary stent implantation. Thromb Haemost. 2012;107:1161-1171.
Pilgrim T, Heg D, Roffi M, et al. Ultrathin strut biodegradable polymer sirolimus-eluting stent versus durable polymer everolimus-eluting stent for percutaneous coronary revascularisation (BIOSCIENCE): a randomised, single-blind, non-inferiority trial. Lancet. 2014;384:2111-2122.
Nakamura M, Kadota K, Nakagawa Y, et al. Ultrathin, biodegradable-polymer sirolimus-eluting stent vs thin, durable-polymer everolimus-eluting stent. JACC Cardiovasc Interv. 2022;15:1324-1334.

Auteurs

David E Kandzari (DE)

Piedmont Heart Institute, Atlanta, Georgia, USA.

Hector M Garcia-Garcia (HM)

Division of Interventional Cardiology, MedStar Cardiovascular Research Network, MedStar Washington Hospital Center, Washington, DC, USA.

Robert C Stoler (RC)

Baylor Scott and White Heart and Vascular Hospital, Dallas, Texas, USA.

John Wang (J)

MedStar Union Memorial Hospital, MedStar Health Research Institute, Baltimore, Maryland, USA.

Mark Picone (M)

Austin Heart, Austin, Texas, USA.

Itsik Ben-Dor (I)

Division of Interventional Cardiology, MedStar Cardiovascular Research Network, MedStar Washington Hospital Center, Washington, DC, USA.

Santiago A Garcia (SA)

The Christ Hospital and Lindner Center for Research and Education, Cincinnati, Ohio, USA.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH