Characterization and Usefulness of Clot-Fibrinolysis Waveform Analysis in Critical Care Patients with Enhanced or Suppressed Fibrinolysis.


Journal

Thrombosis and haemostasis
ISSN: 2567-689X
Titre abrégé: Thromb Haemost
Pays: Germany
ID NLM: 7608063

Informations de publication

Date de publication:
05 Sep 2023
Historique:
pubmed: 2 8 2023
medline: 2 8 2023
entrez: 1 8 2023
Statut: aheadofprint

Résumé

 Recently, clot-fibrinolysis waveform analysis (CFWA), which is a coagulation and fibrinolysis global assay based on assessing the activated partial thromboplastin time with tissue-type plasminogen activator, was developed. This study aimed to investigate the characteristics of CFWA using plasma samples from patients in the critical care unit.  The fibrinolysis times using CFWA were measured in 298 plasma samples. These samples were divided into three groups based on the reference interval (RI) of fibrinolysis time using CFWA: shortened group, less than RI; within group, within RI; prolonged group, more than RI. The coagulation and fibrinolysis markers, including D-dimer, plasmin-α  The FMC level decreased in the order of shortened, within, and prolonged groups, and the decrease was statistically significant among all three group pairs. The opposite tendency was observed for Fbg and fibrinolysis-related markers of α  The fibrinolysis reaction was detected in all three groups, but the status differed. CFWA has the potential to reflect the fibrinolysis status in one global assay.

Identifiants

pubmed: 37527783
doi: 10.1055/a-2145-7139
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Informations de copyright

The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/).

Déclaration de conflit d'intérêts

T.T. and M.H. declare that they have no competing interests. O.K. was an employee of the Sysmex Corporation at the time the work was carried out.

Auteurs

Takumi Tsuchida (T)

Division of Acute and Critical Care Medicine, Department of Anesthesiology and Critical Care Medicine, Hokkaido University Faculty of Medicine, Sapporo, Japan.

Mineji Hayakawa (M)

Division of Acute and Critical Care Medicine, Department of Anesthesiology and Critical Care Medicine, Hokkaido University Faculty of Medicine, Sapporo, Japan.

Osamu Kumano (O)

Sysmex Corporation, Kobe, Japan.
Health and Medical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Takamatsu, Japan.

Classifications MeSH